CPS DIRECT MEDIGUIDE ENABLED OUTER CATHETER

K120296 · St. Jude Medical, Cardiac Rhythm Management Divisi · DQY · May 11, 2012 · Cardiovascular

Device Facts

Record IDK120296
Device NameCPS DIRECT MEDIGUIDE ENABLED OUTER CATHETER
ApplicantSt. Jude Medical, Cardiac Rhythm Management Divisi
Product CodeDQY · Cardiovascular
Decision DateMay 11, 2012
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1250
Device ClassClass 2

Indications for Use

The St Jude Medical CPS Direct MediGuide Enabled slittable outer guide catheter is designed for intracardiac access of the venous system of the heart and to serve as a conduit during implantation for the delivery of contrast medium and St. Jude Medical devices (including implantable left heart leads and delivery tools), and support of fluids where minimizing blood loss is essential. The CPS Direct MediGuide Enabled slittable outer guide catheter is used with the MediGuide System to enable real-time tip positioning and navigation. The MediGuide system is indicated for use as an adjunct to fluoroscopy. In addition, the CPS Direct MediGuide Enabled slittable outer guide catheters can work with inner catheters as a system

Device Story

Slittable outer guide catheter for intracardiac venous access; facilitates delivery of contrast media, fluids, and cardiac implants (e.g., left heart leads). Features PEBAX shaft with stainless steel braid reinforcement; distal tip embedded with sensor coil for MediGuide system tracking; tungsten stripes for fluoroscopic visibility. Hub includes integrated hemostasis valve, sideport for aspiration/flush, and connector port for sensor cable. Operated by physicians in clinical settings; used as adjunct to fluoroscopy. Sensor coil enables real-time tip positioning and navigation via MediGuide system. Provides conduit for inner catheters; minimizes blood loss during procedures.

Clinical Evidence

Bench testing only. No clinical data presented.

Technological Characteristics

PEBAX shaft with stainless steel braid reinforcement; progressively decreasing durometer; atraumatic distal tip. Integrated sensor coil for electromagnetic tracking; tungsten stripes for fluoroscopic visibility. Hub includes hemostasis valve, sideport, and sensor connector. Sterilization method not specified. Connectivity via cable to MediGuide system.

Indications for Use

Indicated for patients requiring intracardiac access of the venous system for implantation of cardiac devices, delivery of contrast media, or fluid support. Used as a conduit for delivery tools and left heart leads.

Regulatory Classification

Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K120296 pg 1 of 2 MAY 1 1 2012 Page 15 # Section 5- 510(k) Summary | Submitter : | St Jude Medical, CRMD<br>15900 Valley View Court<br>Sylmar, CA 91324<br>Establishment Registration Number: 2017865 | |----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact Person : | Colleen Canan<br>Staff Regulatory Affairs Specialist<br>Phone (818) 493 2960<br>Fax (818) 493 3615 | | Date Prepared : | January 27, 2012 | | Trade Name : | CPS Direct™ MediGuide™ Enabled Outer Guide Catheter and<br>accessories | | Classification : | Class II – 21 CFR 870.1250<br>Catheter Percutaneous | | Product Code : | DQY | | Predicate Device : | The subject device is equivalent to the following St Jude Medical and<br>MediGuide Devices<br><br>St Jude Medical CPS Direct™ SL II Slittable Outer Catheter (K092075<br>cleared on August 7, 2009)<br><br>MediGuide Guided Measurement Catheter (GMC) (K091781 cleared on<br>October 16, 2009) | | Device Description : | The St. Jude Medical CPS Direct MediGuide Enabled slittable outer guide<br>catheter is made from PEBAX and reinforced with a stainless steel braid.<br>The shaft has progressively decreasing durometers of PEBAX from the<br>proximal to the distal end with a soft, atraumatic distal tip. The distal end<br>is embedded with a sensor coil to enable device tip projection onto the<br>MediGuide system and tungsten stripes for fluoroscopic visibility. The<br>hub contains an integrated hemostasis valve and the proximal shaft is<br>integrated into the hub creating a slit channel. The hub contains a sideport<br>with extension tubing for contrast delivery, aspiration or saline flush using<br>a 3-way stopcock. In addition, the hub contains a port for the connector<br>cable. | {1}------------------------------------------------ K120296 pg 2of2 | Intended Use: | The St Jude Medical CPS Direct MediGuide Enabled slittable outer guide<br>catheter is designed for intracardiac access of the venous system of the<br>heart and to serve as a conduit during implantation for the delivery of<br>contrast medium and St. Jude Medical devices (including implantable left<br>heart leads and delivery tools), and support of fluids where minimizing<br>blood loss is essential. The CPS Direct MediGuide Enabled slittable outer<br>guide catheter is used with the MediGuide System to enable real-time tip<br>positioning and navigation. The MediGuide system is indicated for use as<br>an adjunct to fluoroscopy. In addition, the CPS Direct MediGuide<br>Enabled slittable outer guide catheters can work with inner catheters as a<br>system | |------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Comparison to<br>Predicate Devices | The St Jude Medical CPS Direct MediGuide Enabled slittable outer guide<br>catheter (from herein referenced as CPS Direct MediGuide Enabled outer<br>catheter kit) has a similar intended use and the same fundamental<br>scientific technology as the predicate devices. All technological<br>characteristics of CPS Direct MediGuide Enabled outer catheter kit are<br>substantially equivalent to the predicate devices including packaging,<br>biocompatibility, sterilization, and labeling. Where differences exist<br>between the subject device and the predicate devices performance testing<br>demonstrated that these differences do not adversely affect the safety and<br>effectiveness of the subject device. | | Conclusion : | St Jude Medical considers the CPS Direct MediGuide Enabled outer<br>catheter kit to be equivalent to the predicate devices listed above. This<br>conclusion is based upon the device similarities in design, technological<br>characteristics, principle of operation, materials and indications for use. | {2}------------------------------------------------ ## DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a stylized eagle with its wings spread, symbolizing protection and service. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES. USA" are arranged in a circular pattern around the eagle. #### Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Room-WO66-G609 Silver Spring, MD 20993-0002 St. Jude Medical c/o Ms. Colleen Canan 15900 Valley View Court Sylmar, CA 91342 MAY 1 1 2012 Re: K120296 Trade/Device Name: CPS Direct MediGuide Enabled Outer Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous catheter Regulatory Class: Class II (two) Product Code: DOY Dated: May 7, 2012 Received: May 9, 2012 #### Dear Ms. Canan: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28. 1976. the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH.does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ ### Page 2 - Ms. Colleen Canan Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely yours, Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ K120296 pg bf1 Page 14 #### Indications for Use Device Name: CPS Direct™ Mediguide Enabled™ Slittable Outer Guide Catheter Models DS2M021, DS2M022, DS2M023 Indications for Use: The St. Jude Medical™ CPS Direct™, Mediguide™ Enabled slittable outer guide catheter is designed for intracardiac access of the venous system of the heart and to serve as a conduit during implantation for the delivery of contrast medium and St. Jude Medical™ devices (including implantable left heart leads and delivery tools), and support of fluids where minimizing blood loss is essential. The CPS Direct™, Mediguide Enabled slittable outer guide catheter are used with the Mediguide™ System to enable realtime tip positioning and navigation. The Mediguide™ system is indicated for use as an adjunct to fluoroscopy. In addition, the CPS Direct™, Mediguide™ Enabled slittable outer guide catheters can work with inner catheters as a system. # (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) # Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use \$\underset{\text{(Part 21 CFR 801 Subpart D)}}{\text{X}}\$ AND/OR Over-The-Counter Use **__** (21 CFR 801 Subpart C) (Division Sign-Off) Division of Cardiovascular Devices 510(k) Number K120 296
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...