TROJAN HER PLEASURE (RIBBED) ECSTASY LATEX CONDOM WITH LUBRICANT
K120286 · Church & Dwight Co., Inc. · HIS · Jun 19, 2012 · Obstetrics/Gynecology
Device Facts
Record ID
K120286
Device Name
TROJAN HER PLEASURE (RIBBED) ECSTASY LATEX CONDOM WITH LUBRICANT
Applicant
Church & Dwight Co., Inc.
Product Code
HIS · Obstetrics/Gynecology
Decision Date
Jun 19, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 884.5300
Device Class
Class 2
Attributes
Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K120286 · Jun 19, 2012
TROJAN HER PLEASURE (RIBBED) ECSTASY LATEX CONDOM WITH LUBRICANT
Church & Dwight Co., Inc.
Branded consumer preference study
The study evaluated the performance (slippage and breakage rates) of the subject device compared to three currently marketed TROJAN latex condoms in a consumer-use setting.
Branded consumer preference study; Consumer-use performance study
1250+ couples; Sample Size: 1250+ couples (500+ using subject device; 750+ using control devices)
Three currently marketed TROJAN latex condoms
Slippage rate, breakage rate, and total failure rate
Indications for Use
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is used for contraception and for prophylactic purposes (to help prevent pregnancy and the transmission of sexually transmitted infections).
Device Story
Male condom consisting of natural rubber latex sheath with silicone-based lubricant; features ribbed texture and bulbous closed end. Designed for over-the-counter use by consumers for contraception and STI prevention. Device provides physical barrier; performance verified via slip/break testing in consumer preference studies. Meets ASTM D3492-08 specifications for shaped condoms. Intended to provide aesthetic variation while maintaining safety and efficacy comparable to predicate devices.
Clinical Evidence
Consumer-use performance study involving >1250 couples compared subject device to three marketed control condoms. Subject device slippage rate 1.99% (controls 0.00%-1.09%); breakage rate 0.46% (controls 0.00%-0.54%); total failure rate 2.45% (controls 0.00%-1.53%). Biocompatibility testing included in vitro cytotoxicity, vaginal/penile irritation, acute systemic toxicity, sensitization, and bacterial reverse mutation assay. Physical testing confirmed compliance with ASTM D3492-08.
Technological Characteristics
Material: Natural rubber latex. Design: Contour-shaped with ribs, bulbous closed end, silicone-based lubricant. Dimensions: 200 mm length, 52-54 mm nominal flat-width (open end), 73 mm flat-width (bulbous end). Standards: ASTM D3492-08, 21 CFR 801.435. Sterilization: Not specified.
Indications for Use
Indicated for use by individuals for contraception and the prevention of sexually transmitted infections.
Regulatory Classification
Identification
A condom is a sheath which completely covers the penis with a closely fitting membrane. The condom is used for contraceptive and for prophylactic purposes (preventing transmission of sexually transmitted infections). The device may also be used to collect semen to aid in the diagnosis of infertility.
Special Controls
*Classification.* (1) Class II (special controls) for condoms made of materials other than natural rubber latex, including natural membrane (skin) or synthetic.(2) Class II (special controls) for natural rubber latex condoms. The guidance document entitled “Class II Special Controls Guidance Document: Labeling for Natural Rubber Latex Condoms Classified Under 21 CFR 884.5300” will serve as the special control. See § 884.1(e) for the availability of this guidance document.
Predicate Devices
TROJAN® (TM-TDB) Latex Condom with Lubricant (K912901)
Submission Summary (Full Text)
{0}------------------------------------------------
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant 510(k) Notification
June 13, 2012
K120286
age
1 of 2
(Revised)
Submitted by:
Church & Dwight Co., Inc. 469 North Harrison Street Princeton, NJ 08543
Contact Person:
Joseph Ciccone Manager, Regulatory Affairs Phone: (609) 497-7251 Fax: (609) 497-7179 eMail: JOSEPH.CICCONE@CHURCHDWIGHT.COM
Date Prepared:
June 13, 2012
Proprietary Name:
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant
Common Name:
Natural Rubber Latex Condom with Lubricant
Classification Name:
Condom [21CFR §884.5300] HIS
Predicate Device:
TROJAN® (TM-TDB) Latex Condom with Lubricant (K912901) [Secondary Brand Name HER PLEASURE™ added when introduced to market]
Description of Device: The TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is a male condom consisting of a sheath of natural rubber latex with a silicone-based lubricant, designed with ribs and a larger bulbous end than the predicate device. The condom has a nominal length of 200 mm and a maximum nominal flat-width of 52-54 mm. measured 30 mm from the open end. The bulbous portion at the closed end of the condom has a flat-width of 73 mm. The condom is consistent with the specifications in ASTM D3492-08 for condoms having a shaped profile about the closed end.
Intended Use of the Device: The 510(k)-subject TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant has the same intended use as the predicate TROJAN® HER PLEASURE™ Latex Condom with Lubricant (K912901). TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is used for contraception and for prophylactic purposes (to help prevent pregnancy and other sexually transmitted infections).
(continued)
{1}------------------------------------------------
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant 510(k) Notification
June 13, 2012
Technological Characteristics: The 51Q(k)-subject TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant has a similar contour-shaped condom design (shape, lubricated condoms with an integral formed ring at the open-end) and material (natural rubber latex) as the predicate HER PLEASURE™ device reviewed and cleared under 510(k) K912901. The 510(k)-subject condom has been modified to add ribs on the wall of the condom, add more room in the bulbous area by increasing the width, and remove the nipple-end at the condom. The nominal flat-width remains 52-54 mm, measured at 30 mm from the open-end of the condom as specified by ASTM D3492-08. Labeling for the 510(k)-subject device is consistent with the Special Controls provisions of 21 CFR §884.5300 and that of the predicate device. The primary purpose of the added ribbing and added room in the bulbous area of the condom is based on preferred aesthetics by the consumer.
## Summary of Studies
Biocompatibility Studies - Biocompatibility studies applicable to the TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant were performed on the final 510(k)-subject device. These studies include in vitro cytotoxicity extract test; vaginal irritation test; penile irritation test; acute systemic toxicity; sensitization test; bacterial reverse mutation assay. TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is considered safe for consumer use under normal and reasonably forseeable misuse conditions.
Consumer-use performance data - FDA's recognition of D3492-08 notes that, "FDA will also carefully evaluate any condom whose nominal width exceeds 58 mm" (recognition #22, 09/08/2009). Slip/Break data from a branded consumer preference study which included the 510(k)-subject condom and three other currently marketed TROJAN® latex condoms was made part of this 510(k) for FDA's review. More than 1250 couples participated in this study (500+ using over 1300 TROJAN® ECSTASY® condoms and 750+ using more than 2200 currently marketed TROJAN® latex condoms). The slippage rate for the TROJAN® HER PLEASURE" (Ribbed) ECSTASY® Condom was 1.99%, and for the control condoms was 1.09%, 0.99% and 0.00%. The breakage rate for the TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Condom was 0.46%, and for the control condoms was 0.11%, 0.54%, and 0.00%. The total failure rate for TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom was 2.45%, and for the control condoms was 1.20%, 1.53%, and 0.00%. These results support that the slip and break rates of the TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom is comparable to currently marketed latex condoms.
Physical testing data - Three (3) lots of the TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant were tested and met specifications of ASTM D 3492-08 Standard Specifications for Rubber Contraceptives (Male Condoms).
Shelf-life - Stability of the 510(k)-subject device was established from results of physical testing data using a protocol that followed 21 CFR \$801.435 as a guide. Based on the evaluation of the results of the physical testing data, the expiration date has been initially set at 36 months and will be then verified through real-time stability through five (5) years in compliance with FDA expiration date labeling requirements in 21 CFR §801.435.
Accordingly, when compared to the predicate HER PLEASURE™ male latex condom, the data from the performance and biocompatibility studies demonstrate that the TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is substantially equivalent to the predicate.
{2}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services USA. The seal is circular, with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized image of a bird, possibly an eagle, with its wings spread.
## Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
JUN 1 9 2012
Mr. Joseph Ciccone Manager, Regulatory Affairs Church & Dwight Co., Inc. 469 North Harrison Street PRINCETON NJ 08543
Re: K120286
> Trade/Device Name: TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant
Regulation Number: 21 CFR& 884.5300
Regulation Name: Condom Regulatory Class: II Product Code: HIS Dated: April 13, 2012 Received: April 16, 2012
Dear Mr. Ciccone:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical
{3}------------------------------------------------
device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Bayard R. Ewks.
Benjamin R. Fisher, Ph.D. Director Division of Reproductive, Gastro-Renal, and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
## Indications for Use
510(k) Number:
Device Name:
Indications for Use:
K120286
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant
TROJAN® HER PLEASURE™ (Ribbed) ECSTASY® Latex Condom with Lubricant is used for contraception and for prophylactic purposes (to help prevent pregnancy and the transmission of sexually transmitted infections).
Prescription Use
OR . Over-the-Counter Use _ X
(Per 21 CFR §8001.109)
Concurrence of CDRH, Office of Device Evaluation (ODE)
uctive, Gastro-Renal, and
Image /page/4/Picture/14 description: The image shows the logo for Trojan brand condoms. The logo features the word "TROJAN" in bold, sans-serif font, with the tagline "BRAND CONDOMS" in smaller letters underneath. To the right of the wordmark is a stylized depiction of a Trojan warrior's head, complete with a helmet. The logo is black and white.
Church & Dwight Co., Inc.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.