SIDE EFFECT WITH HAND CONTROLS, HOOK ELECTRODE WITH HAND CONTROLS, 2.3 WEDGE ELECTRODE WITH HAND CONTROLS, S90 WITH HAND
K120095 · Depuy Mitek, A Johnson & Johnson Company · GEI · Apr 6, 2012 · General, Plastic Surgery
Device Facts
Record ID
K120095
Device Name
SIDE EFFECT WITH HAND CONTROLS, HOOK ELECTRODE WITH HAND CONTROLS, 2.3 WEDGE ELECTRODE WITH HAND CONTROLS, S90 WITH HAND
Applicant
Depuy Mitek, A Johnson & Johnson Company
Product Code
GEI · General, Plastic Surgery
Decision Date
Apr 6, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4400
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The DePuy Mitek VAPR Electrodes for use with the VAPR System are intended for resection, ablation and excision of soft tissue, hemostasis of blood vessels and coagulation of soft tissue in patients requiring arthroscopic surgery of the knee, shoulder, ankle, elbow, and wrist.
Device Story
VAPR Electrodes with Handcontrols are electrosurgical accessories for arthroscopic surgery; used in knee, shoulder, ankle, elbow, and wrist procedures. Device features integrated three-button handpiece for controlling ablation, coagulation, and generator mode functions; connects to VAPR VUE generator. Generator recognizes electrode via ID components in plug; operates at pre-determined default settings, modifiable within safe limits via generator or footswitch. Used by surgeons in clinical settings. Benefits include improved ergonomic control during tissue resection and hemostasis without altering fundamental electrosurgical technology.
Clinical Evidence
No clinical data. Bench testing only. Verification included performance testing for handle integrity, fluid ingress, system compatibility, and capacitance, all of which met product specifications.
Technological Characteristics
Electrosurgical cutting/coagulation device; one-piece handle with integrated three-button hand-control interface. Connects to VAPR VUE generator; includes ID recognition components in plug. Operates via RF energy for tissue ablation/coagulation. Class II device.
Indications for Use
Indicated for patients requiring arthroscopic surgery of the knee, shoulder, ankle, elbow, and wrist for soft tissue resection, ablation, excision, hemostasis, and coagulation.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
{0}------------------------------------------------
never stop moving"
# 1 OF 3
APR - 6 2012
મુ
## 510(k) SUMMARY
| Date Prepared | January 11, 2012 |
|----------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Submitter's Name<br>and Address: | DePuy Mitek, Inc.<br>a Johnson & Johnson company<br>325 Paramount Drive<br>Raynham, MA 02767 |
| Contact Person | Susan Kagan<br>Project Manager, Regulatory Affairs<br>Telephone: 508-880-8097<br>Facsimile: 508-977-6911<br>e-mail: skagan@its.jnj.com |
| Name of Medical<br>Device | Classification Name: Electrosurgical cutting and coagulation device<br>and accessories: 21 CFR 878.4400<br><br>Common/Usual Name: Electrosurgical cutting and coagulation device<br>and accessories: Arthroscope<br><br>Proprietary Name: Side Effect with Hand controls<br>Hook Electrode with Hand controls<br>2.3 Wedge Electrode with Hand controls<br>S90 with Hand controls<br>P50 with Hand controls<br><br>FDA Classification: II<br><br>FDA product code: GEI |
| Predicate<br>Device(s) | The proposed P50 Electrode with Handcontrols is substantially<br>equivalent to: |
- K002422: VAPR 90º Suction Electrode (August 31, 2000) ■
- K082643: VAPR Electrodes with Handpieces (December 19, 2008) .
- K100638: VAPR VUE including CP90 Handcontrol (June 18, 2010) ■
Premarket Notification: Traditional 510(k) VAPR Electrodes with Handcontrols
ﻤﺴﺮ . "
Page 1
{1}------------------------------------------------
The proposed S90 Electrode with Handcontrols is substantially equivalent to:
- 1 K041135: VAPR LPS Electrode (May 10, 2004)
- K082643: VAPR Electrodes with Handpieces (December 19, 2008) 트
- 피 K100638: VAPR VUE including CP90 Handcontrol (June 18, 2010)
The proposed Side Effect, Hook and Wedge Electrode with Handcontrols are substantially equivalent to:
- K963783 Mitek Electrosurgical System (December 25, 1996) 트
- . K082643 VAPR Electrode with Integrated Electrode (December 19, 2008)
- : K100638 VAPR VUE including CP90 with handcontrols (June 18, 2010)
Device Description
The VAPR Electrodes with Handcontrol are similar in technological characteristics, geometry and materials, as their predicated except they will now be available with integrated handcontrol capabilities via three buttons mounted on the existing one-piece handles.
These buttons control ablation, coagulation and the generator mode functions. The plug of the electrode is designed to fit the VAPR VUE generator (K100638: June 18, 2010) socket only and houses the components for ID recognition. They are intended to be run only off the VAPR VUE platform at pre-determined default settings specific for the device. If required, the settings for the device can be modified within safe pre-determined limits by accessing the generator or footswitch control in addition to the buttons on the handpiece.
There are no changes being made to the fundamental technology of the electrode with the exception of the addition of handcontrol functionality.
Indications for Use
The DePuy Mitek VAPR Electrodes for use with the VAPR System are intended for resection, ablation and excision of soft tissue, hemostasis of blood vessels and coagulation of soft tissue in patients requiring arthroscopic surgery of the knee, shoulder, ankle, elbow, and wrist.
Comparison to Predicate Device This submission is intended to demonstrate that the VAPR Electrodes with handcontrols are substantially equivalent to their legally marketed devices.
The Electrodes have been carefully compared to legally marketed devices with respect to intended use, essential components and material, performance specifications and technology characteristics.
Premarket Notification: Traditional 510(k) VAPR Electrodes with Handcontrols
{2}------------------------------------------------
All of the electrodes which are the subject of this submission have the same Indications for Use and technology characteristics. The change to these electrodes is the addition of handcontrol capability which uses the same fundamental technology as the CP90 Electrode and VAPR footswitch.
In addition, safety and performance testing have been done to validate the performance and safety of the device. It has been demonstrated that the addition of handcontrol capability to their predicate electrodes will not affect safety and effectiveness of the subject devices.
Verification of the VAPR Electrodes with handcontrols includes performance testing to show that the device meets its product specifications. Results of performance testing are summarized in Table 1.
Table 1.
| Test | Results |
|---------------------------------------------|---------|
| One Piece Cantilever Handle Separation Test | Pass |
| One Piece Handle Retention Test | Pass |
| Fluid Ingress Test for Finger switches | Pass |
| System Compatibility Test | Pass |
| Capacitance Test | Pass |
Clinical Testing
Safety and Performance
> No clinical studies are required to demonstrate safety and efficacy of the device in support of an application for premarket clearance. The VAPR Electrodes with handcontrols do not differ from the predicate device in fundamental scientific technology or intended use.
#### Conclusion
Results of performance and safety testing have demonstrated that the modified device is suitable for its intended use.
Based on the indications for use, fundamental scientific technology, and comparison to the predicate devices, the VAPR Electrodes with handcontrols which are the subject of this submission are shown to be substantially equivalent to the predicate devices under the Federal Food, Drug and Cosmetic Act.
Premarket Notification: Traditional 510(k) VAPR Electrodes with Handcontrols
Page 3
{3}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES .
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of two main elements: a circular seal on the left and a stylized symbol on the right. The circular seal contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. The symbol on the right is a stylized representation of a human figure, with three curved lines forming the body and head.
#### Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
APR - 6 2012
DePuy Mitek % Ms. Susan Kagan 325 Paramount Drive Raynham, MA 02767
Re: K120095
Trade Name: VAPR electrodes with Hand Controls Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical cutting and coagulation device and accessories Regulatory Class: Class II Product Code: GEI Dated: March 22, 2012 Received: March 23, 2012
Dear Ms. Kagan:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must corply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical Of K F at 607), aboning (21 CFR 803); good manufacturing practice requirements as set
{4}------------------------------------------------
### Page 2 - Ms. Susan Kagan
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Sincerely yours,
Mark A. Millkus
Mark N. Melkerson Director Division of Surgical, Orthopedic, and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
· Enclosure
{5}------------------------------------------------
# Indications for Use
510(k) Number (if known): K120095
Device Name: VAPR Electrodes with Handcontrols
Indications for Use:
The DePuy Mitek VAPR Electrodes for use with the VAPR System are intended for resection, ablation and excision of soft tissue, hemostasis of blood vessels and coagulation of soft tissue in patients requiring arthroscopic surgery of the knee, shoulder, ankle, elbow, and wrist.
Prescription Use X (Part 21 CFR 801 Subpart D) . AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Page 1 of 1
signature
(Division ign-Off) Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number K120095
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.