K113868 · Syneron, Ltd. · GEX · Jun 11, 2012 · General, Plastic Surgery
Device Facts
Record ID
K113868
Device Name
EPLUS SKIN TREATMENT SYSTEM
Applicant
Syneron, Ltd.
Product Code
GEX · General, Plastic Surgery
Decision Date
Jun 11, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4810
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The ePlus Skin Treatment system is intended for dermatological procedures.
Device Story
ePlus Skin Treatment System is a multi-application dermatological device; delivers electromagnetic energy via system applicators. Inputs: electrical power; outputs: optical radiation (Laser or IPL in visible/near-IR range) and 1MHz RF current. Used in clinical settings by trained operators. Applicators include DS, DSL, LV, LVA, WRA, SR, SRA, AC, Sublative RF, and Sublime. Energy delivery targets skin tissue for hair reduction, vascular/pigmented lesion treatment, acne therapy, and skin resurfacing/wrinkle reduction. Benefits include non-invasive or ablative skin rejuvenation and lesion management. Clinical decision-making relies on operator selection of appropriate applicator based on patient skin type and condition.
Clinical Evidence
No clinical data provided. Safety and efficacy were established by reference to the clinical performance data of the predicate devices that utilize the same applicators.
Technological Characteristics
Multi-application system delivering optical radiation (Laser/IPL) and 1MHz RF current. Complies with IEC 60601-1 (safety), IEC 60601-2-2 (high frequency surgical equipment), IEC 60601-2-22 (laser equipment), IEC 60825-1 (laser safety), and IEC 60601-1-2 (EMC).
Indications for Use
Indicated for hair removal and permanent hair reduction (all skin types I-VI, including tanned skin); treatment of vascular lesions; non-invasive wrinkle treatment; treatment of superficial benign vascular and pigmented lesions (lentigines, freckles, telangiectasia, rosacea, poikiloderma, angioma, sun spots, age spots) on face, chest, hands, arms, or sporadic body areas; treatment of moderate inflammatory acne vulgaris; and dermatological procedures requiring skin ablation and resurfacing.
Regulatory Classification
Identification
(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo for Syneron Medical LTD. The word "Syneron" is written in a stylized font, with the "S" being larger and more decorative than the other letters. Below the word "Syneron" is the text "Medical LTD".
# 510(K) SUMMARY
# ePlus Skin Treatment System 510(k) Number K113868
| Applicant's Name: | Syneron Medical Ltd. |
|-------------------|-----------------------|
| | Industrial Zone |
| | Tavor Building |
| | Yokneam Illit 20692 |
| | Israel |
| | Tel: (972)73-244-2200 |
| | Fax: (972)73-244-2202 |
| | |
- Yoram Levy, Osite Contact Person: 31 Haavoda Street Binyamina, Israel 30500 Tel (972)4-638-8837; Fax (972)4-638-0510 Yoram@gsitemed.com
Trade Name:
ePlus Skin Treatment System
December 27. 2011 Preparation Date:
Name: Powered laser surgical instrument Classification: Product Code: GEX, OUH Regulation No: 21 CFR 878.4400, 21CFR 878.4810 Class: II Panel: General and Plastic Surgery
#### Device Description:
The ePlus skin treatment system is a multi-application system that provides a variety of skin treatments. The system combines Syneron's previously cleared Polaris, Aurora and eTwo treatment Systems and their applicators. The ePlus skin treatment system delivers two ranges of electromagnetic energy to the skin tissue through the system applicators:
- Optical radiation through Laser or IPL (Intense Pulse Light) in 1. the visible & near-IR range.
2. RF current conducted through the tissue at 1MHz
#### Intended Use Statement:
The ePlus Skin Treatment system is intended for dermatological procedures.
{1}------------------------------------------------
113868 2/3
# Medical LTD
meron
The DS applicator is indicated for the removal of unwanted hair from skin types I-VI. and to effect stable long-term, or permanent, hair reduction*.
The DSL applicator is indicated for hair removal, permanent hair reduction*. The applicator is intended for use on all skin types. (Fitzpatrick skin type I-VI), including tanned skin.
The LV applicator is indicated for treatment of vascular lesions.
The LVA applicator is indicated for treatment of vascular lesions.
The WRA applicator is indicated for non invasive wrinkles treatment.
The SR applicator is intended for superficial benign vascular and pigmented lesion treatment such as:
lentigines. freckles. telangiectasia. rosacea. poikiloderma, angioma, sun spots and age spots.
The SR treatment may be performed on body areas such as the face. chest. hands and arms. It can be also performed on sporadic lesions anywhere on the body.
The SRA applicator is intended for superficial benign vascular and pigmented lesion treatment such as:
lentigines. freckles. telangiectasia. rosacea. poikiloderma. angioma, sun spots and age spots.
The SRA treatment may be performed on body areas such as the face, chest, hands and arms. It can be also performed on sporadic lesions anywhere on the body.
The AC applicator is indicated for the treatment of moderate inflammatory acne vulgaries.
The Sublative RF applicator is indicated for Dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles.
The Sublime applicator is indicated for non invasive wrinkles treatment.
* Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen
Substantial equivalence to the following predicate devices is Predicate Devices: claimed:
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image contains the word "Syneron" in a stylized font. The word is written in black ink and appears to be part of a logo or brand name. Below the word "Syneron" is the word "Medical LTD".
113 867. 7/3
# Medical LTD
| Syneron Device Name | 510k No | Date of Clearance |
|-------------------------------|---------|--------------------|
| Polaris DS / Comet Applicator | K041959 | November 8, 2004 |
| Polaris LV | K030186 | April 14, 2003 |
| Polaris WR | K031671 | December 1, 2003 |
| Aurora SR | K031993 | August 1, 2003 |
| AC applicator, Aurora AC | K032514 | January 27, 2004 |
| Aurora DS, DS applicator | K050796 | April 12, 2005 |
| Aurora SR and SRA applicator | K050452 | March 9, 2005 |
| Polaris LV, LVA applicator | K052324 | September 14, 2005 |
| eTwo Skin Treatment System | K110672 | October 03, 2011 |
#### Performance Standards:
#### ePlus Skin Treatment System complies with:
- . IEC 60601-1 : "Medical Electrical Equipment" Part 1: "General requirements for safety"
- IEC 60601-2-2: "Medical Electrical Equipment" Part 2: "Particular . requirements for the safety of high frequency surgical equipment" (2006)
- IEC 60601-2-22 : "Medical Electrical Equipment" Part 2: . ● "Particular requirements for the safety of diagnostic and therapeutic laser equipment" (1995)
- IEC60825-1 : Safety of laser products Part 1: "Equipment . classification, requirements and user's guide" (2007)
- IEC 60601-1-2 Ed. 2.1 (2004): medical electrical equipment: Part . 1-2 collateral standard: Electromagnetic compatibility Requirements and tests"
A detailed description appears in Section 13.
#### Summary of Clinical Performance Data:
The safety and efficacy of the ePlus Skin Treatment System was evaluated in the clearance process of the predicate devices that use the same applicators that are part of this device. Syneron believes that clinical data is not required to determine the safety and efficacy of the ePlus Skin Treatment System since the intended use and technical performance of ePlus and its applicators are equivalent to the predicate devices.
{3}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three lines representing its wings and body. The eagle is positioned to the right of a circular arrangement of text that reads "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA".
#### Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
JUN 1 1 2012
- Syneron. Ltd Yo Osite Yoram Levy 31 Haavoda Street Binyamina, Israel 30500
Re: K113868
Trade/Device Name: ePlus Skin Treatment System Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology
Regulatory Class: Class II Product Code: GEX Dated: June 01, 2012 Received: June 05, 2012
Dear Yoram Levy:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
#### Page 2 - Yoram Levy
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Mark Millikan
Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Ineron Medical LTD
# INDICATIONS FOR USE STATEMENT
#### 510(k) Number (if known): K113868
Device Name:
ePlus Skin Treatment System
Indications for Use:
The ePlus Skin Treatment system is intended for dermatological procedures.
The DS applicator is indicated for the removal of unwanted hair from skin types I-VI, and to effect stable long-term, or permanent, hair reduction*.
The DSL applicator is indicated for hair removal. permanent hair reduction*. The applicator is intended for use on all skin types, (Fitzpatrick skin type I-VI), including tanned skin.
The LV applicator is indicated for treatment of vascular lesions.
The LVA applicator is indicated for treatment of vascular lesions.
The WRA applicator is indicated for non invasive wrinkles treatment.
The SR applicator is intended for superficial benign vascular and pigmented lesion treatment such as:
lentigines, freckles, telangiectasia, rosacea, poikiloderma, angioma, sun spots and age spots.
The SR treatment may be performed on body areas such as the face, chest, hands and arms. It can be also performed on sporadic lesions anywhere on the body.
The SRA applicator is intended for superficial benign vascular and pigmented lesion treatment such as:
lentigines. freckles, telangiectasia, rosacea, poikiloderma, angioma, sun spots and age spots.
The SRA treatment may be performed on body areas such as the face, chest, hands and arms. It can be also performed on sporadic lesions anywhere on the body.
The AC applicator is indicated for the treatment of moderate inflammatory acne vulgaries.
## ePlus Skin Treatment System - 510(k) Notification
Neil RPDoplin for mxm
(Division Sign-Off)
Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number K113868
{6}------------------------------------------------
Image /page/6/Picture/0 description: The image shows the logo for Syneron Medical LTD. The word "Syneron" is written in a stylized font, with the "S" having a unique design. Below "Syneron" is the text "Medical LTD" in a standard, bold font. The logo appears to be for a medical company.
The Sublative RF applicator is indicated for Dermatological procedures requiring ablation and resurfacing of the skin, and for the treatment of facial wrinkles.
The Sublime applicator is indicated for non invasive wrinkles treatment.
*Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6. 9, and 12 months after the completion of a treatment regimen
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEEDED).
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Division Sign-off), Division of General, Restorative and Neurological Devices 510(k) Number
Neihroplen Sir mxm
(Division Sign-Division of Surgical, Orthopedic, and Restorative Devices
510(k) Number K113868
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.