K113748 · Imris, Inc. · HBL · Mar 23, 2012 · Neurology
Device Facts
Record ID
K113748
Device Name
IMRIS MR/X-RAY HEAD FIXATION DEVICE (HFD)
Applicant
Imris, Inc.
Product Code
HBL · Neurology
Decision Date
Mar 23, 2012
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 882.4460
Device Class
Class 2
Indications for Use
The IMRIS MR/X-ray Head Fixation Device System is an MR safe mechanical support system which is used in head, neck and spine surgery when rigid fixation is required for cranial stabilization. The MR/X-ray HFD is indicated for use during utilization of imaging modalities such as intraoperative MRI, CT imaging, and C-Arm X-ray angiography.
Device Story
Mechanical support system for rigid cranial stabilization during surgery; immobilizes head in prone, supine, or lateral positions. Comprises table adaptor, linkage system, and 3-pin skull clamp. Used in operating rooms or angiography suites; operated by surgical staff. Compatible with intraoperative MRI, CT, and C-Arm X-ray imaging. Provides stable positioning to facilitate surgical access and imaging; benefits patient by maintaining precise alignment during complex neurosurgical procedures.
Clinical Evidence
Bench testing only. No clinical data provided. Testing included usability, workflow, loading, third-party accessory compatibility, MRI compatibility (artifacts and heating), radiolucency, and reliability.
Indicated for patients undergoing head, neck, or spine surgery requiring rigid cranial stabilization. Used during intraoperative MRI, CT imaging, and C-Arm X-ray angiography. No specific age or gender contraindications listed.
Regulatory Classification
Identification
A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures.
{0}------------------------------------------------
IMRIS
510(k) Summary for MR/X-ray HFD
# 510(k) SUMMARY FOR MR/X-ray HFD
MAR 2 3 2012
KII37
(As required by 21 CFR 807.92)
#### 1. GENERAL INFORMATION
IMRIS Inc.
Address:
Establishment:
Registration Number:
Contact Person:
3003807210 Mr. Sanjay Shah QA and Regulatory Engineer Email: sshah@imris.com Phone: 1-204-480-7070 Fax: 1-204-480-7071
100-1370 Sony Place
Winnipeg, Manitoba Canada, R3T 1N5
| Date of Summary Preparation: | March 6, 2012 |
|-------------------------------|-----------------------------------------|
| Device Name / Trade name | IMRIS MR/X-ray Head Fixation Device |
| Classification Name: | Neurosurgical head holder (skull clamp) |
| Classification Panel: | Neurology |
| Classification (CFR section): | 21 CFR 882.4460 |
| Class: | Class II |
| Product Code: | HBL |
# 2. PREDICATE DEVICES
The MR/X-ray HFD system is substantially equivalent to the following predicate medical devices.
| NAME OF THE DEVICE | 510(K)<br>NUMBER | DATE OF<br>CLEARANCE | MANUFACTURER |
|-----------------------------------------------------------|------------------|----------------------|-------------------------------------|
| IMRIS Head Fixation Device (HFD100) | K103493 | Nov 29, 2010 | IMRIS Inc. |
| MAYFIELD® MR/X-Ray Skull Clamp | K081401 | Oct 8, 2008 | Integra LifeSciences<br>corporation |
| DORO® Radiolucent/MRI Compatible<br>Cranial stabilization | K063494 | May 21, 2007 | Pro med instruments<br>GmbH |
{1}------------------------------------------------
#### 3. DEVICE DESCRIPTION
The IMRIS MR/X-ray Head Fixation Device System (HFD) is an MR safe mechanical support system intended to be used in head, neck and spine surgery when rigid fixation is recruined for cranial stabilization. The IMRIS MR/X-ray HFD has been designed for use with intra-perative MR imaging, Xray Fluoroscopy and CT imaging modality.
The IMRIS MR/X-ray HFD and its accessories are designed to immobilize the head during surgical procedures and support patient in the prone, supine or lateral positions. The IMRIS MR/A Province ട് പ്രേം കേ ray HFD system can be used with either the operating room table or the angigraphy room table. The table adaptor is used to mount IMRIS MR/X-ray HFD on the table. The linkage system is used to mont the Skull Clamp to the table Adapter. The skull clamp (including 3 skull pins) is used to hold head and neck in a particular position during surgical procedures.
### 4. INDICATION FOR USE
The IMRIS MR/X-ray Head Fixation Device System is an MR safe mechanical support system which is used in head, neck and spine surgery when rigid fixation is required for cranial stabilization. The MRXray HFD is indicated for use during utilization of imaging modalities such as intraoperativer. MI, CT imaging, and C-Arm X-ray angiography.
| | 5. COMPARISON TO PREDICATE DEVICES | |
|--|------------------------------------|--|
|--|------------------------------------|--|
| Manufacturer | Integra LifeSciences<br>Corporation | Pro med instruments<br>GmbH | IMRIS Inc. | IMRIS Inc. | |
|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------|
| FDA 510(k) # | K081401 | K063494 | K103493 | Subject Device | |
| Trade/Device Name | MAYFIELD® MR/X-Ray<br>Skull Clamp | DORO®<br>Radiolucent/MRI<br>Compatible Cranial<br>Stabilization and<br>Halo Systems and<br>accessories | HFD100 | MR/X-RAY HFD | |
| Product Code | HBL | HBL | HBL | HBL | |
| FDA Classification | 21 CFR 882.4460 | 21 CFR 882.4460 | 21 CFR 882.4460 | 21 CFR 882.4460 | |
| Indication for use | The MAYFIELD® MR/X-<br>Ray Skull clamp is<br>placed on the patient's<br>skull to hold their head<br>and neck securely in a<br>particular position when<br>rigid fixation is desired.<br>The clamp is indicated<br>for use in open and<br>percutaneous<br>craniotomies as well as<br>spinal surgery when rigid<br>fixation is necessary. In<br>addition, the clamp is<br>indicated for use during<br>utilization of imaging<br>modalities such as<br>intraoperative CT and<br>MR imaging, C-Arm X-<br>ray, and digital<br>subtraction techniques. | The Radiolucent<br>MRI Compatible<br>Skull Clamp<br>Headrest System<br>with Skull Pins<br>The DORO®<br>Radiolucent / MRI<br>Compatible Skull<br>Clamp Headrest<br>System with Skull<br>Pins are components<br>of a mechanical<br>support system<br>which is used in<br>head and neck<br>surgery when rigid<br>skeletal fixation is<br>required for cranial<br>stabilization and<br>when intra-operative<br>CT or MR Imaging is<br>used.<br>The Radiolucent /<br>MRI Compatible<br>Horseshoe Headrest<br>System<br>The DORO® | The IMRIS Head<br>Fixation Device<br>System is an MR<br>compatible<br>mechanical support<br>system which is<br>used in head, neck<br>and spine surgery<br>when rigid fixation<br>is required for<br>cranial stabilization. | The IMRIS MR/X-<br>ray Head Fixation<br>Device System is<br>an MR safe<br>mechanical support<br>system which is<br>used in head, neck<br>and spine surgery<br>when rigid fixation<br>is required for<br>cranial stabilization.<br>The MR/X-ray HFD<br>is indicated for use<br>during utilization of<br>imaging modalities<br>such as<br>intraoperative MRI,<br>CT imaging, and C-<br>Arm X-ray<br>angiography. | |
| | | Radiolucent / MRI<br>Compatible<br>Horseshoe Headrest<br>System are<br>components<br>of a mechanical<br>support system<br>which is used in<br>head and neck<br>surgery when non-<br>invasive<br>head support is<br>required and when<br>intra-operative CT or<br>MR Imaging is used. | | | |
| CHARACTERIS<br>TIC | Integra<br>LifeSciences<br>Corporation<br>MAYFIELD®<br>MR/X-Ray Skull<br>Clamp<br>(K081401) | Pro med<br>instruments<br>GmbH<br>DORO®<br>Radiolucent/MRI<br>Compatible<br>Cranial<br>Stabilization and<br>Halo Systems<br>and accessories<br>(K063494) | IMRIS Inc.<br>IMRIS HFD100<br>(K103493) | IMRIS Inc.<br>IMRIS MR/X-<br>RAY HFD<br>(Current<br>submission) | COMPARISION |
| Skull Clamp | 3-Pin Skull.<br>clamp | 3-Pin Skull<br>clamp | 3-Pin Skull<br>clamp | 3-Pin Skull<br>clamp | Same |
| MRI system<br>Compatibility | MRI compatible | MRI compatible | MRI compatible | MRI safe | Same |
| Used with<br>Imaging Modality | Intraoperative<br>CT and MR<br>imaging, C-Arm<br>X-ray, and digital<br>subtraction | Intra-operative<br>CT or MR | Intraoperative<br>MRI | Intraoperative<br>MRI, CT<br>imaging, and C-<br>Arm X-ray<br>angiography. | Same as Integra<br>and Pro med |
| Material | Composite<br>materials | NOVOTEX<br>laminated fabric<br>with phenolic<br>resin<br>(GRP) colored<br>with BASANTOL<br>black X82 liquid<br>and POM<br>(Delrin), PEEK<br>and Polyurethan | Titanium, Teflon<br>coated<br>fiberglass<br>phenolic<br>composites and<br>Acetol (POM) | PEEK, Teflon,<br>Cast Acrylic | Different |
| Mounting | Two pin<br>mounting<br>mechanism On<br>Standard OR<br>Table | Two pin<br>mounting<br>mechanism On<br>Standard OR<br>Table | Two pin<br>mounting<br>mechanism On<br>IMRIS design<br>OR table or<br>Angio table | Two pin<br>mounting<br>mechanism On<br>IMRIS design<br>OR table or<br>Angio table | Same as<br>HFD100 |
| Support load | 20kg | 12.5kg | 20kg | 20kg | Same |
| Pin force | 80lb | 80lb | 80lb | 80lb | Same |
| Application | General<br>neurosurgical<br>procedures<br>Intra-operative<br>neurosurgical<br>procedures | General<br>neurosurgical<br>procedures<br>Intra-operative<br>neurosurgical<br>procedures | General<br>neurosurgical<br>procedures<br>Intra-operative<br>neurosurgical<br>procedures | General<br>neurosurgical<br>procedures<br>Intra-operative<br>neurosurgical<br>procedures | General<br>neurosurgical<br>procedures<br>Intra-operative<br>neurosurgical<br>procedures |
| CHARACTERIS<br>TIC | Integra<br>LifeSciences<br>Corporation<br>MAYFIELD®<br>MR/X-Ray Skull<br>Clamp<br>(K081401) | Pro med<br>instruments<br>GmbH<br>DORO®<br>Radiolucent/MRI<br>Compatible<br>Cranial<br>Stabilization and<br>Halo Systems | IMRIS Inc.<br>IMRIS HFD100<br>(K103493) | IMRIS Inc.<br>IMRIS MR/X-<br>RAY HFD<br>(Current<br>submission) | COMPARISION |
| | | and accessories<br>(K063494) | | | |
| Sterile Pins | MAYFIELD@<br>Radiolucent<br>Skull Pins A-<br>2020 | DORO®<br>Radiolucent<br>Disposable<br>Single-Use Skull<br>Pins of Yttried | | MAYFIELD@<br>Radiolucent<br>Skull Pins A-<br>2020 | Same<br>(Exactly the<br>same as Integra<br>LifeSciences<br>Corporation<br>Pins) |
| | (FDA 510(k) #<br>K021604) | Zirconium<br>or Titanium are<br>X-ray and MRI<br>compatible. MR-<br>Safe | | | |
| | MAYFIELD®<br>Titanium<br>Disposable Child<br>Skull Pin A1119 | | MAYFIELD®<br>Titanium<br>Disposable Child<br>Skull Pin A1119 | MAYFIELD®<br>Titanium<br>Disposable Child<br>Skull Pin A1119 | |
| | (FDA 510(k) #<br>K072208) | | | | |
| | MAYFIELD®<br>Titanium<br>Disposable Adult<br>Skull Pin A1120 | | MAYFIELD®<br>Titanium<br>Disposable Adult<br>Skull Pin A1120 | MAYFIELD®<br>Titanium<br>Disposable Adult<br>Skull Pin A1120 | |
| | (FDA 510(k) #<br>K072208) | | | | |
| | MAYFIELD®<br>Adult Skull Pin,<br>Titanium A1121 | | MAYFIELD®<br>Adult Skull Pin,<br>Titanium A1121 | MAYFIELD®<br>Adult Skull Pin,<br>Titanium A1121 | |
| | (FDA 510(k) #<br>K072208) | | | | |
| | MAYFIELD®<br>Child Skull Pin,<br>Titanium A1122 | | MAYFIELD®<br>Child Skull Pin,<br>Titanium A1122 | MAYFIELD®<br>Child Skull Pin,<br>Titanium A1122 | |
| | (FDA 510(k) #<br>K072208) | | | | |
{2}------------------------------------------------
# IMRIS
# 510(k) Summary for MR/X-ray HFD
{3}------------------------------------------------
#### 6. SUMMARY OF THE TECHNOLOGICAL CHARACTERISTICS OF THE DEVICE COMPARED TO THE PREDICATE DEVICE: (807.92 (A) (6))
{4}------------------------------------------------
IMRIS
.
510(k) Summary for MR/X-ray HFD
KIIST
.
{5}------------------------------------------------
K113748
## 7. SUMMARY OF NON-CLINICAL DATA
#### Biocompatibility of Pins:
The skull pins used in the MR/X-ray HFD are invasive. The biocompatibility of pins has been verified by Integra LifeSciences Corporation in K021604 and K072208.
There is no change made by IMRIS. Pins initially included are provided by Integra Life Sciences with their labeling. IMRIS does not relabel the pins. Pins are purchased from Integra LifeSciences Corporation directly.
#### Design Verification and Validation Test (Bench Testing)
The MR/X-ray HFD system passed the following tests and meets product specifications.
The tests include Usability requirements and workflow, Loading test, Third party accessories compatibility test, MRI compatibility test (MR image artifacts test, MR heating test), Radiolucency and Reliability test.
#### 8. CONCLUSION
0
The MR/X-ray HFD has the same intended use and indications for use as the predicate devices. Performance data demonstrate safety and effectiveness of the MR/X-ray HFD with the new characteristics.
The IMRIS MR/X-ray HFD verification/validation results and performance/safety standard results show that the device is safe and effective and substantially equivalent to the currently available predicate devices, IMRIS HFD100, Integra LifeSciences MAYFIELD® MR/X-Ray Skull Clamp and Pro med instruments DORO® Radiolucent/MRI Compatible Cranial stabilization.
{6}------------------------------------------------
Image /page/6/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three tail feathers, representing the department's commitment to health, human services, and well-being. The eagle is encircled by the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" in a circular arrangement.
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002
Mr. Sanjay Shah QA and Regulatory Engineer IMRIS Inc. 100-1370 Sony Place R3T 1N5 WINIPEG, MANITOBA CANADA
MAR 2 3 2012
Re: K113748
Trade/Device Name: IMRIS MR/X-ray Head Fixation Device Regulation Number: 21 CFR 882.4460 Regulation Name: Neurosurgical head holder (skull clamp) Regulatory Class: II Product Code: HBL Dated: March 14, 2012 Received: March 15, 2012
#### Dear Mr. Shah:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR). Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of
{7}------------------------------------------------
#### Page 2
medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely Yours,
Janine M. Morris
Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health
Enclosure
{8}------------------------------------------------
# Indications for Use
510(k) Number (if known): K113748
Device Name: IMRIS MR/X-ray Head Fixation Device
Indications for Use:
The IMRIS MR/X-ray Head Fixation Device System is an MR safe mechanical support system which is used in head, neck and spine surgery when rigid fixation is required for cranial stabilization. The MR/X-ray HFD is indicated for use during utilization of imaging modalities such as intraoperative MRI, CT imaging, and C-Arm X-ray angiography.
Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD)
***_****_*. (Division Sign-Off)
Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety
510(k) Number K113748
IMRIS 510(k) Premarket Notification IMRIS MR/X-ray HFD
Page 1 of 1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.