DEL MAR MONOAXIAL PEDICLE SCREW SYSTEM

K110679 · Phygen, LLC · NKB · Aug 2, 2011 · Orthopedic

Device Facts

Record IDK110679
Device NameDEL MAR MONOAXIAL PEDICLE SCREW SYSTEM
ApplicantPhygen, LLC
Product CodeNKB · Orthopedic
Decision DateAug 2, 2011
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 888.3070
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The DEL MAR® Monoaxial Pedicle Screw System is intended to be used in skeletally mature patients as an adjunct to fusion using autograft or allograft in posterior, non-cervical fixation for the following conditions: Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion.

Device Story

The Del Mar® Pedicle Screw System is a spinal fixation implant used for correction, immobilization, and stabilization of thoracic, lumbar, and sacral spinal segments. The system consists of monoaxial screws (30-100mm length; 5-9mm diameter) and connecting rods (5.5mm diameter) that are rigidly locked into patient-specific configurations. Additional components include deformity connectors and single-piece set screws. The device is used by surgeons in clinical settings to facilitate spinal fusion. By providing rigid stabilization, the system supports the fusion process, potentially reducing pain and correcting spinal deformities in patients with degenerative or traumatic conditions.

Clinical Evidence

No clinical data. Bench testing only. Mechanical performance evaluated via static compression bending, static torsion, dynamic compression bending (ASTM F1717-10), and static/axial torque gripping capacity (ASTM F1798-97). Results confirmed equivalence to predicate devices.

Technological Characteristics

Materials: Medical grade titanium alloy (ASTM F136) and Cobalt Chrome alloy (ASTM F1058). Components: Monoaxial screws, rods, deformity connectors, set screws. Mechanical fixation via rigid locking mechanism. Testing standards: ASTM F1717-10, ASTM F1798-97 (2008).

Indications for Use

Indicated for skeletally mature patients requiring posterior, non-cervical spinal fixation as an adjunct to fusion (autograft/allograft) for degenerative disc disease, spondylolisthesis, trauma (fracture/dislocation), spinal stenosis, spinal curvatures (scoliosis, kyphosis, lordosis), tumor, pseudarthrosis, or failed previous fusion.

Regulatory Classification

Identification

(1) Rigid pedicle screw systems are comprised of multiple components, made from a variety of materials that allow the surgeon to build an implant system to fit the patient's anatomical and physiological requirements. Such a spinal implant assembly consists of a combination of screws, longitudinal members (e.g., plates, rods including dual diameter rods, plate/rod combinations), transverse or cross connectors, and interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors).(2) Semi-rigid systems are defined as systems that contain one or more of the following features (including but not limited to): Non-uniform longitudinal elements, or features that allow more motion or flexibility compared to rigid systems.

Special Controls

*Classification.* (1) Class II (special controls), when intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra; degenerative spondylolisthesis with objective evidence of neurologic impairment; fracture; dislocation; scoliosis; kyphosis; spinal tumor; and failed previous fusion (pseudarthrosis). These pedicle screw spinal systems must comply with the following special controls:(i) Compliance with material standards; (ii) Compliance with mechanical testing standards; (iii) Compliance with biocompatibility standards; and (iv) Labeling that contains these two statements in addition to other appropriate labeling information: “Warning: The safety and effectiveness of pedicle screw spinal systems have been established only for spinal conditions with significant mechanical instability or deformity requiring fusion with instrumentation. These conditions are significant mechanical instability or deformity of the thoracic, lumbar, and sacral spine secondary to severe spondylolisthesis (grades 3 and 4) of the L5-S1 vertebra, degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis). The safety and effectiveness of these devices for any other conditions are unknown.” “Precaution: The implantation of pedicle screw spinal systems should be performed only by experienced spinal surgeons with specific training in the use of this pedicle screw spinal system because this is a technically demanding procedure presenting a risk of serious injury to the patient.” (2) Class II (special controls), when a rigid pedicle screw system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion in the treatment of degenerative disc disease and spondylolisthesis other than either severe spondylolisthesis (grades 3 and 4) at L5-S1 or degenerative spondylolisthesis with objective evidence of neurologic impairment. These pedicle screw systems must comply with the following special controls: (i) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (ii) Non-clinical performance testing must demonstrate the mechanical function and durability of the implant. (iii) Device components must be demonstrated to be biocompatible. (iv) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (v) Labeling must include the following: (A) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (B) Intended use and indications for use, including levels of fixation; (C) Identification of magnetic resonance (MR) compatibility status; (D) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user; and (E) Detailed instructions of each surgical step, including device removal. (3) Class II (special controls), when a semi-rigid system is intended to provide immobilization and stabilization of spinal segments in the thoracic, lumbar, and sacral spine as an adjunct to fusion for any indication. In addition to complying with the special controls in paragraphs (b)(2)(i) through (v) of this section, these pedicle screw systems must comply with the following special controls: (i) Demonstration that clinical performance characteristics of the device support the intended use of the product, including assessment of fusion compared to a clinically acceptable fusion rate. (ii) Semi-rigid systems marketed prior to the effective date of this reclassification must submit an amendment to their previously cleared premarket notification (510(k)) demonstrating compliance with the special controls in paragraphs (b)(2)(i) through (v) and paragraph (b)(3)(i) of this section.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K110679 ## 510(k) Summary AUG - 2 2011 [in accordance with 21 CFR 807.92(c)] ij | Contact: | Mr. Hartmut Loch<br>Vice President<br>Regulatory Affairs & Quality Assurance<br>Phygen, LLC.<br>2301 Dupont Drive, Suite 510<br>Irvine CA 92612<br>Tel: 1-949-752-7885 x 117<br>Fax: 1-949-752-7665 | |--------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Date Prepared: | March 7, 2011 | | Trade name:<br>Common name: | Spinal Fixation System | | Classification<br>name: | Orthosis, Spinal Pedicle Fixation, For Degenerative Disc Disease<br>- § 888.3070 (NKB) – class III<br>Appliance, Fixation, Spinal Interlaminal - § 888.3050 (KWP) - class II<br>Spinal Intervertebral Body Fixation Orthosis § 888.3060 (KWQ) - class II<br>Pedicle Screw Spinal System - § 888.3070 (MNI) - class II<br>Pedicle Screw Spinal System - § 888.3070 (MNH) - class II<br>All Orthopedic Device Panel 87 | | Product Codes: | NKB, KWP, KWQ, MNI, MNH | | Device Description<br>and Characteristics: | The Del Mar® Pedicle Screw System is intended to help provide correction,<br>immobilization and stabilization of spinal segments as an adjunct to fusion of<br>the thoracic, lumbar and/or sacral space. The Del Mar® Pedicle Screw<br>System consists of a variety of rods and screws, which can be rigidly locked<br>into a variety of configurations, with each construct being tailor-made to fit<br>the patient's individual anatomy. Monoaxial screws are supplied in winged<br>and non-winged configurations, in a variety of length, ranging from 30 mm to<br>100 mm and in 5 mm, 6 mm, 7 mm, 8mm and 9 mm diameter sizes. All<br>sizes are able to receive 5.5mm connecting rods only. Pre-bent rods are<br>available in 10 mm increments from 30 to 120 mm in length. | | | Additional components, such as a Single Piece Set Screw, Cobalt Chrome<br>Rods ranging from 400 mm to 600 mm and several types of Deformity<br>Connectors have been added. The Del Mar® Pedicle Screw System implant<br>components are fabricated from medical grade titanium alloy per ASTM<br>F136 and Cobalt Chrome alloy per ASTM F1058. | | Equivalence: | The modified Del Mar® Pedicle Screw System is substantially equivalent to<br>the Del Mar® Pedicle Screw System (K091219 S/E 7/9/2009 and unmodified<br>K051275 S/E 12/9/2005, which is manufactured and marketed by Phygen,<br>LLC. | {1}------------------------------------------------ K110679 The Del Mar® Pedicle Screw System is intended to be used in skeletally . Indications: mature patients as an adjunct to fusion - using - autograft - or - allograft - inposterior, non-cervical fixation for the following conditions: > Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion. The following mechanical tests have been performed per ASTM F1717-10: Performance data: - a. Static Compression Bending Tests - b. Static Torsion Test - c. Dynamic Compression Bending Tests In addition the following tests per ASTM F1798-97 (2008) were performed: - d. Static Axial Gripping Capacity - e. Axial Torque Gripping Capacity The test results were equivalent to the predicate device and/or other similar implants and are sufficient for in vivo loading. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows a logo for the Department of Health & Human Services. The logo features a stylized caduceus symbol, which is a traditional symbol of medicine. The text "DEPARTMENT OF HEALTH & HS" is arranged in a circular fashion around the caduceus symbol. The logo is black and white. Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002 Phygen, LLC % Mr. Hartmut Loch Vice President Regulatory Affairs & Quality Assurance 2301 Dupont Drive, Suite 510 Irvine, California 92612 AUG - 2 2011 Re: K110679 Trade/Device Name: DEL MAR® Monoaxial Pedicle Screw System Regulation Number: 21 CFR 888.3070 Regulation Name: Pedicle screw spinal system Regulatory Class: Class III Product Code: NKB, MNI, MNH, K WP, K WQ Dated: July 18, 2011 Received: July 19, 2011 Dear Mr. Loch: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you; however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 – Mr. Hartmut Loch Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Sincerely vours. Mark N. Melkerson Director Division of Surgical, Orthopedic And Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 510(k) Number (if known): ¡¿ 1 (0679 DEL MAR® Monoaxial Pedicle Screw System Device Name(s): ಿ ಮಾರ್ಥಿಸಿದ Indications for Use: The DEL MAR® Monoaxial Pedicle Screw System is intended to be used in skeletally mature patients as an adjunct to fusion using autograft or allograft in posterior, non-cervical fixation for the following conditions: Degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion. Prescription Use X (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C) please do not write below this line - continue on another page if needed Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Diysion of Surgical, Orthopedic, and Restorative Devices 510(k) Number_________________________________________________________________________________________________________________________________________________________________ Page _ 1_ of __ 1 __
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...