The MV intradermic needles are intended to inject fluids intradermally.
Device Story
Device consists of metal cannula with closed blunt tip and lateral opening; joined to female Luer connector hub for attachment to piston syringe. Marketed alone or with pilot needle (sharpened hypodermic needle) to prepare injection site. Used by clinicians to deliver fluids intradermally. Device is single-use and sterile. Blunt tip design facilitates intradermal delivery; lateral opening allows fluid exit while preventing tissue coring. Benefits include precise intradermal fluid administration.
Clinical Evidence
No clinical data. Bench testing performed per ISO 7864 (cleanness, extractable metals, tube dimensions, hub/tube bond strength, lumen evidence) and biocompatibility testing (cytotoxicity, sensitization, intracutaneous reactivity, systemic toxicity, haemocompatibility) per ISO 14971:2007 risk analysis. All results met requirements.
Indicated for intradermal injection of fluids. No specific patient population, age, or gender restrictions provided.
Regulatory Classification
Identification
A hypodermic single lumen needle is a device intended to inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin. The device consists of a metal tube that is sharpened at one end and at the other end joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe or an intravascular administration set.
{0}------------------------------------------------
#### 510(K) NOTIFICATION
K110606
M.V. Intradermic Needle
SEP 2 9 2011
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
# 510 (k) Summary of safety and effectiveness
### SUBMITTER INFORMATION
| A. | Company Name: | M.V. s.r.l. |
|----|-------------------------|-------------------------------------------------------------------------------------------------------|
| B. | Company Address: | Via F.lli Cervi, 7<br>Gonzaga (MN), Italy 46023 |
| | Manufacturing facility: | Via Don G. Dossetti, 5/7<br>Gonzaga (MN), Italy 46023 |
| | US Agent: | Laura Andreatta<br>N. Devon Rd., Columbus, OH 43212,<br>Phone +1-614-246-1141<br>Fax: +1-614-725-0890 |
| C. | Company Phone: | +39 0376 536995 |
| | Company Fax: | +39 0376 530441 |
| | Company e-mail | info@mvsrl.it |
| D. | Contact Person: | Enrico Bisson<br>Studio ingegneria Enrico Bisson |
| E. | Contact Phone: | +39 0498630080 |
| | Contact Fax | +39 0498630080 |
| | Contact E-mail | enrico.bisson@isoplan.org |
| F. | Date Summary Prepared: | February 28, 2011 |
## DEVICE IDENTIFICATION
- A. Device name: M.V. Intradermic Needles
- B. Trade/Proprietary Name: M.V. Intradermic Needles
- ். Hypodermic Single Lumen Needle (21 CFR §880.5570) Classification name:
- FMI D. Product Code:
#### LEGALLY MARKETED DEVICES (PREDICATE DEVICES)
- ARTSANA HYPODERMIC NEEDLES, K051783 -
{1}------------------------------------------------
#### DEVICE DESCRIPTION
The device is comprised of a metal tube. On one end the tip is closed and blunt, while the cannula has an opening laterally at a lower point under the tip. On the other end the device is joined to a female connector (hub) designed to mate with a male connector (nozzle) of a piston syringe.
The MV intradermic needle is marketed alone or combined with a pilot needle. The pilot needle is an hypodermic single lumen needle intended to prepare the site for injection. The tip of the pilot needle is sharpened at one end, while the other end is joined to a hub. The pilot needle can be any traditional legally marketed hypodermic needle.
The MV intradermic needles are single-use devices sold as sterile.
#### INTENDED USE
The MV intradermic needles are intended to inject fluids intradermally.
#### DISCUSSION OF NON CLINICAL TESTS
Following performance tests were performed on the MV Intradermic Needles to test their compliance with Recognized Consensus Standard ISO 7864 Sterile hypodermic needles for single use:
Cleanness
Acidity or alkalinity limits Limits for extractable metals Needle tube - Length requirements Needle tube - Absence of defects Execution - Hub/tube bond strength Execution - Evidence of lumen
None of the data raised any issues of safety and effectiveness. Additionally, a risk analysis was conducted according to Recognized Consensus Standard ISO 14971:2007.
Following biological tests were performed on the sterile finished device to evalute biocompatibility:
Cytotoxicity, Sensitization, Intracutaneous reactivity, Systemic toxicity
Haemocompatibility.
None of the result of the tests arised any issues of biocompatibility.
#### SUBSTANTIAL EQUIVALENCE
The MV Intradermic Needles are same or similar in design, materials and intended use to the predicate devices. In further support of a substantial equivalence determination, Section 10 provides a comparison chart of the submitted device and the predicate devices. Main comparison element are as follows:
Confidential
Page 15 -3
{2}------------------------------------------------
.
| | MV INTRADERMIC NEEDLES | K051783 |
|--------------------------------------|--------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------|
| Intended /<br>Indications<br>For Use | The MN intradermic needles are<br>intended to inject fluids<br>intradermally. | To inject fluids into, or withdraw<br>fluids from, parts of the body<br>below the surface of the skin. |
| Cannula<br>material | AISI 304 Stainless Steel | AISI 304 Stainless Steel |
| Hub material | Polypropylene | Polypropylene |
| Needle<br>diameter | 22G, 25G, 27G, 30G;<br>21G, 23G, 26G, 27G | 21G, 22G, 23G, 25G, 26G, 27G,<br>30G and more |
| Needle length<br>(mm) | 25, 27, 35, 37, 40, 50, 57, 70;<br>13, 25 | 13, 25, 40 and more |
| Tip<br>configuration | closed blunt tip, lateral opening<br>(intradermic needle),<br>triple sharpened, non-coring (pilot<br>needle) | triple sharpened, non-coring |
| Hub | color coded ISO 6009 | color coded ISO 6009 |
| Connection<br>to syringe | Luer taper | Luer taper |
Based on the available information, we conclude that the M.V. Intradermic Needles are substantially equivalent to the existing legally marketed devices under Federal Food, Drug and Cosmetic Act. Therefore, the applicant device is determined as safe and effective.
#### SAMPLE
Sample of the MV Intradermic Needles is included in this submission.
·
・
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows a logo with a stylized bird in flight. The bird is composed of three curved lines that suggest movement and feathers. The logo is encircled by text, which is difficult to read due to the image quality. The overall design is simple and abstract, conveying a sense of freedom and flight.
rood ... d Drig Adminstration 16903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002
M.V. S.R.L. C/O Mr. Enrico Bisson President Studio di Ingegneria Enrico Bisson .Via Marzia 9 Abano Terme, Padova Italy 35031
SEP 2 9 2011
Re: K110606 Trade/Device Name: MV Intradermic Needles Regulation Number: 21 CFR 880.5570 Regulation Name: Hypodermic Single Lumen Needle Regulatory Class: II Product Code: FMI Dated: September 9, 2011 Received: September 16, 2011
Dear Mr. Bisson:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind-you-however; that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
# Page 2- Mr. Bisson
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that vour device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 331-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801). please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm 1 15809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safetv/Reportal/roblem/default.htmlfor the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely vours.
Wh for
Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology. General Hospital Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
## Enclosure
{5}------------------------------------------------
# INDICATIONS FOR USE
510(k) Number (if known):
K110606
Device Name:
MV intradermic needles
Indications for Use:
The MV intradermic needles are intended to inject fluids intradermally.
Prescription Use × (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(Please DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Rhd C. Chyn 9/28/1,
(Division Sign-Off)
Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: K110606
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.