ENI-EYE SH TORIC (EFROFILCON A) SOFT HYDROPHILIC TORIC CONTACT LENS FOR DAILY WEAR, MULTIFOCAL CONTACT LENS, KERATOCONUS
Device Facts
| Record ID | K110261 |
|---|---|
| Device Name | ENI-EYE SH TORIC (EFROFILCON A) SOFT HYDROPHILIC TORIC CONTACT LENS FOR DAILY WEAR, MULTIFOCAL CONTACT LENS, KERATOCONUS |
| Applicant | Soflex Limited |
| Product Code | LPL · Ophthalmic |
| Decision Date | Jul 28, 2011 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 886.5925 |
| Device Class | Class 2 |
Indications for Use
The Eni-Eye SH Toric (Efrofilcon A) Soft (hydrophilic) Contact Lens for Daily Wear is indicated for daily wear for the correction of refractive astigmatism with non-diseased eyes that may exhibit refractive and/or corneal astigmatism. The lens may be disinfected using a chemical disinfection system. The Eni-Eye Q SH Multi (Efrofilcon A) Soft (hydrophilic) Multifocal Contact Lens for Daily Wear is indicated for daily wear for the correction of refractive ametropia (myopia and hyperopia) and presbyopia in aphakic and/or non aphakic persons with non-diseased eyes. The lenses may be disinfected using a chemical disinfection system. The Eni-Eye Q SH Multi Toric (Efrofilcon A) Soft (hydrophilic) Multifocal Contact Lens for Daily Wear is designed to correct ametropia (myopia and hyperopia), presbiopia, and corneal astigmatism in aphakic and/or non aphakic persons with non-diseased eyes. The lenses may be disinfected using a chemical disinfection system. The ENI-EYE SH Soft K (Efrofilcon A) Soft (hydrophilic) Keratoconus and irregular cornea Contact Lens for Daily Wear is indicated for daily wear for persons requiring keratoconus management and for the correction of refractive ametropia (myopia and hyperopia) in aphakic and non-aphakic persons that may exhibit refractive and/or corneal astigmatism, or post-refractive surgery corneal irregularity such as irreqular astigmatism up to 2.00 D that does not interfere with visual acuity. The lens may be disinfected with a chemical or heat disinfection system. The Eni-Eye SH Soft K Toric (Efrofilcon A) Soft (hydrophilic) Keratoconus and irregular cornea Contact Lens for Daily Wear is indicated for daily wear for persons requiring keratoconus management and for the correction of refractive ametropia (myopia and hyperopia) in aphakic and non-aphakic persons that may exhibit refractive and/or corneal astigmatism, or post-refractive surgery corneal irregularity such as irregular astigmatism up to 2.00DS that does not interfere with visual acuity. The lens may be disinfected with a chemical or heat disinfection system.
Device Story
Soft (hydrophilic) contact lenses made of Efrofilcon A; designed for daily wear. Corrects refractive errors including astigmatism, myopia, hyperopia, presbyopia, and keratoconus. Prescribed by eye care professionals for patients with non-diseased eyes. Lenses placed directly on the cornea to modify light refraction. Disinfection via chemical or heat systems. Benefits include improved visual acuity and management of irregular corneal conditions.
Clinical Evidence
No clinical data provided; substantial equivalence based on technological characteristics and intended use.
Technological Characteristics
Material: Efrofilcon A (hydrophilic polymer). Form factor: Soft contact lens. Disinfection: Chemical or heat systems. Class II device (21 CFR 886.5925).
Indications for Use
Indicated for daily wear in non-diseased eyes for correction of refractive astigmatism, myopia, hyperopia, presbyopia, and keratoconus management. Applicable to aphakic and non-aphakic persons, including those with post-refractive surgery corneal irregularity (up to 2.00 D).
Regulatory Classification
Identification
A soft (hydrophilic) contact lens is a device intended to be worn directly against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as a therapeutic bandage. The device is made of various polymer materials the main polymer molecules of which absorb or attract a certain volume (percentage) of water.