K103550 · Fosham Yoboshi Medical Equipment Co., Ltd. · EIA · Jan 4, 2011 · Dental
Device Facts
Record ID
K103550
Device Name
YOBOSHI DENTAL UNIT
Applicant
Fosham Yoboshi Medical Equipment Co., Ltd.
Product Code
EIA · Dental
Decision Date
Jan 4, 2011
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.6640
Device Class
Class 1
Attributes
3rd-Party Reviewed
Indications for Use
The Dental Unit with Chair is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair
Device Story
Yoboshi Dental Unit (models A8000, A8000-I, A8000-II) serves as a powered base for dental instruments; includes patient chair, ceramic spittoon, air-controlled instrument arm, and cold light. Driven by low-voltage DC motor with air spring balance for stability and noise reduction. Features include NSK high-speed and low-speed handpieces, electric pedal switch, and adjustable headrest/backrest. Used in dental clinics by dentists and assistants. Provides stable platform and power for dental procedures; enhances patient comfort via seamless leather cushion; facilitates cleaning and disinfection. Optional video system available for specific models.
Clinical Evidence
Bench testing only. Compliance with ISO 7494-1:2004, ISO 7494-2:2003, ISO 9168:1991, ISO 13294:1997, and ISO 6875:1995. Electrical safety and EMC testing per IEC 60601-1 and IEC 60601-1-2. Biocompatibility testing per ISO 10993-5 & -10.
Technological Characteristics
Dental unit with DC motor, air spring balance, and ceramic spittoon. Materials include seamless leather. Complies with ISO 7494-1/2 (dental units), ISO 9168 (hose connectors), ISO 13294 (air motors), and ISO 6875 (patient chairs). Electrical safety per IEC 60601-1; EMC per IEC 60601-1-2. Biocompatibility per ISO 10993. Software validation performed per FDA guidance.
Indications for Use
Indicated for use in dental clinics/offices by trained dentists, dental technicians, and assistants to provide power and a base for dental devices and accessories.
Regulatory Classification
Identification
A dental operative unit and accessories is an AC-powered device that is intended to supply power to and serve as a base for other dental devices, such as a dental handpiece, a dental operating light, an air or water syringe unit, and oral cavity evacuator, a suction operative unit, and other dental devices and accessories. The device may be attached to a dental chair.
{0}------------------------------------------------
K103550
Yoboshi Dental Unit- 510(K): Sec. 5
# 510(K) SUMMARY
## JAN - 4 2011
This summary of 510(K) safety and effectiveness information is being submitted in accordance with the requirements of SMDA and 21 CFR 807.92
#### 1.0 Submitter's Information
## Establishment Registration Name:
Foshan Yoboshi Medical Equipment Co., Ltd.
4 Simple Workshop, East city road, (Fuwan) hecheng city street, Gaoming, Foshan, Guangdong China 528500
Contact Person of applicant Mr. Jianjun Zhong - Management Representative ' 4 Simple Workshop, East city road, (Fuwan) hecheng city street, Gaoming, Foshan, Guangdong China 528500
TEL: +86-757-2885 3333 FAX: +86-757-2890 1866 Email:
## Contact Person of the Submission:
Ms. Sabrina Wei
MEDLAB (Shenzhen) Information Service Co., LTD
Room 2706, Block A, ZhongFang JinYuan Buiding, Xinwen Road Shenzhen, Guangdong, P.R. China, 518034
TEL: +86-755-83089699 FAX: +86-755-83089760
Email: sabrinawei(@hotmail.com; ; please CC lingbensuo@gmail.com,
#### 2.0 Device Information
Type of 510(k) submission: Traditional Device Common Name: · Dental Unit with Chair Trade Name: Yoboshi Dental Unit Model: A8000, A8000-I, A8000-II Classification name: · Dental operative unit and accessories
{1}------------------------------------------------
| Review Panel: | Dental |
|--------------------|----------|
| Product Code: | EIA |
| Regulation Class: | I |
| Regulation Number: | 872.6640 |
#### 3.0 Predicate Device Information
| Sponsor: | North West Medical Instrument (Group) Co., Ltd |
|----------------|------------------------------------------------|
| Device: | Dental Unit with Chair, Model: S2300 |
| 510(K) Number: | K080438 |
#### 4.0 Device description
Yoboshi dental units with chairs are driven by imported low-voltage DC motor with imported air spring auxiliary balance to keep a safe and stable operation of equipment and low noise. With two pieces of NSK high speed H.P and one piece of NSK lowspeed H.P, it is easy and credible for working. The single-form seamless leather cushion provides comfort for the patient to sit and for the doctor to clean and disinfect more easily. It is applicable for the dental clinic. The unit is composed of integral ceramic spittoon, air-controlled balanced instrument-arm, newlydesigned cold light.
The models include A8000, A8000-I, A8000-II. All of these types follow the same design principle and intended use, and comply with ISO7494-1:2004, ISO7494-2:2003. The hose connectors of these types comply with ISO9168:1991. The air-motors of these types comply with ISO13294: 1997. Dental patient chair complies with ISO 6875:1995.
All of these types of applicant devices consist of similar components with similar function and different appearance, these components include:
- Electric pedal switch ●
- Control key for mouth lamp
- Wash cuspidor
- Gargle water control
- Pedal switch
- Handrail
- Backrest
- Headrest
- Cuspidor
- Rising pipe
- Lamp arm
- Operation light
- Seat cushion for child
#### Intended Use 5.0
The Dental Unit with Chair is intended to supply power to and serve as a base for
{2}------------------------------------------------
dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair
#### 6.0 Effectiveness and Safety Considerations
### Effectiveness:
The Dental Unit with Chair complies with ISO7494-1:2004, ISO7494-2:2003, ISO9168: 1991, ISO 6875:1995 and ISO13294: 1997.
### Safety Considerations:
The applicant devices comply with IEC60601-1, Medical electrical equipment - Part 1: General requirements for safety and IEC60601-1-2, Medical electrical equipment - Part 1-2: General requirements for safety -Collateral standard: Electromagnetic compatibility - Requirements and tests.
For all hose connectors and air motors, the applicant devices comply with ISO 9168: 1991 and ISO 13294: 1997.
For dental patient chair, the applicant devices comply with ISO 6875:1995.
In regard to biocompatibility evaluation, the applicant devices comply with ISO 111381-1: 2006 for BI material, ISO 11737-1: 2006 for disposable anesthesia channel; ISO 10993-5 & -10 for Single-use anesthesia tube.
The Software Validation is in compliance with FDA Guidance for the Content of Pre-Market Submissions for Software Contained in Medical Devices.
#### Comparison to predicate device and conclusion 7.0
### Comparison Analysis
The applicant device has same classification information, same indications and intended use, similar product design, similar technical specification, biological specification and safety specification. The video system of the applicant device is optional for Model A8000 & A8000-I, and it is substantially equivalent to the predicate device in other parts.
### Conclusion:
The applicant device is Substantially Equivalent (SE) to the predicate device which is US legally marketed device. Therefore, the applicant device is determined as safe and effectiveness.
Compare with predicate device, they are very similar in design principle, intended use, functions, material and the adopting applicable standards. The differences between applicant device and predicate device do not raise any new questions of safety or effectiveness.
{3}------------------------------------------------
## DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes representing the department's mission of providing essential human services. The eagle is positioned to the right of the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA", which is arranged in a circular fashion around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MID 20993-0002
Fosham Yoboshi Medical Equipment Company, Limited C/O Mr. Mark Job Responsible Third Party Official Regulatory Technology Services, LLC 1394 25th Street, NW Buffalo, Minnesota 55313
JAN - 4 2011
Re: K103550
Trade/Device Name: Yoboshi Dental Unit with Chair Regulation Number: 21 CFR 872.6640 Regulation Name: Dental Operative Unit and Accessories Regulatory Class: I Product Code: EIA Dated: December 21, 2010 Received: December 22, 2010
Dear Mr. Job:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2- Mr. Job
Enclosure
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ ucm 1 1 5809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Susan Russer
Anthony D. Watson, B.S., M.S., M.B.A. Director
Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
{5}------------------------------------------------
# Statement of Indications for Use
510(k) Number (if known):
K103556
Device Name: Model:
Yoboshi Dental Unit with Chair A8000, A8000-I, A8000-II
JAN - 4 2011
Indications for Use:
The Dental Unit with Chair is intended to supply power to and serve as a base for dental devices and accessories. It is intended for use in the dental clinic/office environment and used by trained dentists and/or dental technicians and assistants. This product is attached with a dental chair
Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) is use Stidfer
> Division Sign-Off) iivision of Anesthesiology, General Hospital nfection Control, Dental Devices
آران وجود اللود والموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الموقع الم 510(k) Number:
Concurrence of CDRH, Office of Device Evaluation (ODE)
Page_1_of_1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.