HOLTER IN-LINE SHUNT FILTER, HOLTER CEREBRAL CATHETER RESERVOIR, ACCU-FLO CONNECTORS; ACCU-FLO THREE WAY CONNECTOR; CODM
K102961 · Codman & Shurtleff, Inc. · JXG · Feb 18, 2011 · Neurology
Device Facts
Record ID
K102961
Device Name
HOLTER IN-LINE SHUNT FILTER, HOLTER CEREBRAL CATHETER RESERVOIR, ACCU-FLO CONNECTORS; ACCU-FLO THREE WAY CONNECTOR; CODM
Applicant
Codman & Shurtleff, Inc.
Product Code
JXG · Neurology
Decision Date
Feb 18, 2011
Decision
SESE
Submission Type
Special
Regulation
21 CFR 882.5550
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The hydrocephalus accessories are intended for use with Codman's Hydrocephalus Shunt Systems.
Device Story
Hydrocephalus shunt system accessories include connectors, reservoirs, and an in-line filter. Connectors (stainless steel or plastic) join and fixate silicone rubber tubing; reservoirs (silicone, stainless steel, plastic) provide access to cerebral ventricles or intracranial cavities for diagnostic/therapeutic purposes; in-line filter removes particles from CSF. Used in surgical settings by neurosurgeons during shunt implantation or revision. Devices facilitate fluid diversion to the right atrium or peritoneal cavity. No active electronic components or software; purely mechanical accessories. Benefit: enables reliable shunt system assembly, maintenance of fluid pathways, and access for clinical interventions.
Clinical Evidence
Bench testing only. Evaluation performed per ASTM F 2052, ASTM F 2213, ASTM F 2119, and ASTM F 2182. Results confirm devices are MR Conditional or MR Safe in 3-Tesla MRI systems per ASTM F 2503.
Technological Characteristics
Materials: silicone rubber, stainless steel, plastic. Components: connectors (straight, right-angle, three-way), reservoirs, in-line filter. Mechanical assembly for CSF shunt systems. MR safety evaluated per ASTM F 2052, F 2213, F 2119, F 2182, and F 2503.
Indications for Use
Indicated for patients requiring cerebrospinal fluid (CSF) shunting or drainage for hydrocephalus treatment. Components used for joining/fixation of silicone tubing, accessing cerebral ventricles/intracranial cavities for diagnostic studies or therapeutic drug administration, and filtering particles in shunt systems.
Regulatory Classification
Identification
A central nervous system fluid shunt is a device or combination of devices used to divert fluid from the brain or other part of the central nervous system to an internal delivery site or an external receptacle for the purpose of relieving elevated intracranial pressure or fluid volume (e.g., due to hydrocephalus). Components of a central nervous system shunt include catheters, valved catheters, valves, connectors, and other accessory components intended to facilitate use of the shunt or evaluation of a patient with a shunt.
CODMAN® ACCU-FLO® Connector, Three Way, Plastic (K973774)
CODMAN® ACCU-FLO® Right Angle Connector, Plastic (K973774)
Submission Summary (Full Text)
{0}------------------------------------------------
# 510(k) SUMMARY
i
!
FEB 18 2011
1
| Company Name: | Codman & Shurtleff, Inc. |
|--------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Company Address: | 325 Paramount Drive<br>Raynham, MA 02767-0350 |
| Phone: | (508) 828-3421 |
| Fax: | (508) 828-2777 |
| Contact Person: | Jocelyn Raposo, Senior Regulatory Affairs Specialist |
| Date: | October 4, 2010 |
| Name of the Device: | Central Nervous System Fluid Shunt and Components |
| Propriety / Trade Name: | CODMAN® HOLTER® In-Line Shunt Filter, Hoffman Design<br>CODMAN® HOLTER® Cerebral Catheter-Reservoir, LeRov Design<br>CODMAN® ACCU-FLO® Straight Connector, Stainless Steel<br>CODMAN® MEDOS® Straight Connector<br>CODMAN® HOLTER® Type A Fixation and Joining Connector<br>CODMAN® HOLTER® Type B Fixation and Joining Connector<br>CODMAN® ACCU-FLO® Connector, Three Way, Stainless Steel<br>CODMAN® HOLTER® RICKHAM® Reservoir<br>CODMAN® HOLTER® SALMON™-RICKHAM® Reservoir<br>CODMAN® ACCU-FLO® Right Angle Connector, Stainless Steel<br>CODMAN® MEDOS® Right Angle Connector<br>CODMAN® HOLTER® SELKER Reservoir<br>CODMAN® ACCU-FLO® Straight Connector, Plastic<br>CODMAN® ACCU-FLO® Connector, Three Way, Plastic<br>CODMAN® ACCU-FLO® Right Angle Connector, Plastic |
| Common Name: | Hydrocephalus Shunt System Accessories |
| Classification: | Class II (JXG) per 21 CFR § 882.5550<br>Central Nervous System Fluid Shunt and Components |
| Legally Marketed Device: | Preamendment - CODMAN® HOLTER® In-Line Shunt Filter,<br>Hoffman Design<br>Preamendment - CODMAN® HOLTER® Cerebral Catheter-<br>Reservoir, LeRoy Design<br>Preamendment – CODMAN® ACCU-FLO® Straight Connectors |
{1}------------------------------------------------
| K944222 | - CODMAN® MEDOS® Straight Connector |
|------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Preamendment | - CODMAN® HOLTER® Type A Fixation and Joining Connector |
| Preamendment | - CODMAN® HOLTER® Type B Fixation and Joining Connector |
| Preamendment | - CODMAN® ACCU-FLO® Connector, Three Way |
| Preamendment | - CODMAN® HOLTER® RICKHAM® Reservoir |
| Preamendment | - CODMAN® HOLTER® SALMON™-RICKHAM® Reservoir |
| Preamendment | - CODMAN® ACCU-FLO® Right Angle Connectors |
| K944222 | - CODMAN® MEDOS® Right Angle Connector |
| Preamendment | - CODMAN® HOLTER® SELKER Reservoir |
| K973774 | - CODMAN® ACCU-FLO® Straight Connector, Plastic |
| K973774 | - CODMAN® ACCU-FLO® Connector, Three Way, Plastic |
| K973774 | - CODMAN® ACCU-FLO® Right Angle Connector, Plastic |
| <b>Device Description:</b> | The hydrocephalus accessories consist of connectors, reservoirs, and a filter. The connectors are made of stainless steel or plastic and are used in the joining and fixation of silicone rubber tubing. The reservoirs are made of silicone, stainless steel, and/or plastic and are used for the purpose of diagnostic studies or therapeutic drug administration. The filter is made of stainless steel and silicone and is used to filter particles. |
| <b>Intended Use:</b> | The hydrocephalus accessories are intended for use with Codman's Hydrocephalus Shunt Systems. |
| <b>Summary of technological characteristics of the proposed to the predicate device:</b> | |
| | No new technological characteristics are being introduced in comparison to the predicate devices. The technological characteristics of the devices remain the same. No changes are being made to the device design, materials, performance, or intended use. |
| <b>Performance Data:</b> | Bench testing was performed according to the following MRI standards: ASTM F 2052, ASTM F 2213, ASTM F 2119, and ASTM F 2182. The test results demonstrate that there is no added risk to the patient when exposed to a 3 Tesla MR system. The devices that are |
made of silicone and plastic were evaluated and determined to be MR Safe since they do not contain metallic or conducting materials. The
.
:
i
…..
2
{2}------------------------------------------------
# K102961
results and evaluation conclude that the devices are MR Conditional or MR Safe in 3-Tesla Magnetic Resonance Imaging (MRI) systems according to ASTM F 2503 and are substantially equivalent to the predicate devices.
i
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for the Department of Health & Human Services (HHS). The logo features a stylized image of an eagle with three lines representing its wings and body. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
Codman & Shurtleff. Inc. c/o Ms. Jocelyn Raposo Senior Regulatory Affairs Specialist 325 Paramount Drive Raynham, MA 02767-0350
#### FEB 1 8 2011
#### Re: K102961
Trade/Device Name: CODMAN® HOLTER® In-Line Shunt Filter, Hoffman Design CODMAN® HOLTER® Cerebral Catheter-Reservoir, LeRoy Design CODMAN® ACCU-FLO® Straight Connector, Stainless Steel CODMAN® MEDOS® Straight Connector CODMAN® HOLTER® Type A Fixation and Joining Connector CODMAN® HOLTER® Type B Fixation and Joining Connector CODMAN® ACCU-FLO® Connector, Three Way, Stainless Steel CODMAN® HOLTER® RICKHAM® Reservoir CODMAN® HOLTER® SALMON™-RICKMAN® Reservoir CODMAN® ACCU-FLO® Right Angle Connector, Stainless Steel CODMAN® MEDOS® Right Angle Connector CODMAN® HOLTER® SELKER Reservoir CODMAN® ACCU-FLO® Straight Connector, Plastic CODMAN® ACCU-FLO® Connector, Three Way, Plastic CODMAN® ACCU-FLO® Right Angle Connector, Plastic
Regulation Number: 21 CFR 882.5550 Regulation Name: Central nervous system fluid shunt and components Regulatory Class: II Product Code: JXG Dated: January 18, 2011 Received: January 19, 2011
#### Dear Ms. Raposo:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of
{4}------------------------------------------------
devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
- Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
Tesia Alexander
Malvina B. Eydelman, M.D. Director Division of Ophthalmic, Neurological, and Ear. Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
{5}------------------------------------------------
માળટવદા 510(k) Number (if known): __
Device Name:
CODMAN® MEDOS® Straight Connector CODMAN® MEDOS® Right Angle Connector
Indications for Use:
The Codman-Medos Connector is for use in the treatment of hydrocephalus as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated.
Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
K102961 510(k) Number
{6}------------------------------------------------
1102961 510(k) Number (if known):
Device Name:
CODMAN® HOLTER® Type A Fixation and Joining Connector
Indications for Use:
The Type A Fixation and Joining Connector is indicated for use in the joining and fixation of 1.2 rite Type P. Pixation and coming with nonabsorbable sutures in a surgical application.
Prescription Use
(Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use _ (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
510(k) Number K102961
{7}------------------------------------------------
K102961 510(k) Number (if known): _
Device Name:
CODMAN® HOLTER® Type B Fixation and Joining Connector
Indications for Use:
The Type B Fixation and Joining Connector is indicated for use in the joining and fixation of 0.8 me rype b fixation and obling to 1.2 mm nominal I.D. silicone rubber tubing, and min fromman f.D. Billions fulls of the version in a surgical applical application.
Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use _ (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
4102961 ^^^^ \(^imber
{8}------------------------------------------------
510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________
Device Name:
CODMAN® HOLTER® SEL.KER Reservoir CODMAN® HOLTER® RICKHAM® Reservoir CODMAN® HOLTER® SAL.MON™-RICKHAM® Reservoir
Indications for Use:
The Ventriculostomy Reservoir Set is indicated for use to gain access to the cerebral ventricles or other intracranial cavities for the purpose of diagnostic studies or therapeutic drug administration with or without a shunting device. When used with the shunting device, the ventriculostomy reservoir is also indicated for use as the proximal fluid pathway.
· Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
4102a61 510(k) Number_
{9}------------------------------------------------
510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________
Device Name:
CODMAN® ACCU-FLO® Connector, Three Way (Stainless Steel and Plastic)
Indications for Use:
The ACCU-FLO Three Way Connector can be utilized as a component in systems designed to The ACCO-FLO Three Way Ochniction our be unities into the right atium of the heart or the shunt cereorospinal had from the lateral vonthologime and fixation of approximately 1.3 mm
peritoneal cavity, providing they are used in the joining aurrical application pentioneal cavily, providing they are about in the John's and surgical application.
Prescription Use
(Part 21 CFR 801 Subpart D) X
AND/OR
Over-The-Counter Use _ (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
510(k) Number K102961
{10}------------------------------------------------
ત્વજવદા 510(k) Number (if known): __
Device Name:
CODMAN® ACCU-FLO® Straight Connectors (Stainless Steel and Plastic) OODMAN® ACCU-FLO® Right Angle Connectors (Stainless Steel and Plastic)
Indications for Use:
The ACCU-FLO Connectors can be utilized as a component in systems designed to shunt The AOOO+ LO Ochhoolors our be anticles into the right atrium of the heart or the peritoneal cerebrospiral not from the joining and fixation of approximately 1.3 mm nominal I.D. silicone rubber tubing with nonabsorbable sutures in a surgical application.
× ´ Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (Part 21 CFR 801 Subpart C)
JOE HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
KID2961 510(k) Number_
{11}------------------------------------------------
મા૦ટવદા 510(k) Number (if known): _
Device Name:
CODMAN® HOLTER® Cerebral Catheter Reservoir, Leroy Design
Indications for Use:
The Cerebral Catheter-Reservoir is indicated for use as a component of a shunting system to The Gerebral Vatheter-1000Non in Indication for see and cavities for the purpose of diagnostic studies, therapeutic drug administration, or the diversion of fluid.
Prescription Use
X
(Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (Part 21 CFR 801 Subpart C)
Joe HUTTER
(Division Sign-Off) Division of Ophthalmic, Neurological and Ear, Nose and Throat Devices
KIDZACI 510(k) Number.
{12}------------------------------------------------
510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________
Device Name:
CODMAN® HOLTER® In-Line Shunt Filter, Hoffman Design
Indications for Use:
The In-Line Shunt Filter is indicated for use to filter particles that are larger than approximately The in Line Gham Mis suspected and when shunting is the procedure of choice in the treatment of hydrocephalus.
Prescription Use
(Part 21 CFR 801 Subpart D) X
AND/OR
Over-The-Counter Use _ (Part 21 CFR 801 Subpart C)
JOE HUTTER
ision Sign-Off) · of Ophthalmic, Neurological and Ear, "Froat Devices
K102961 STUCK , Nomber __
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.