K102536 · Convatec, Inc. · EZQ · Dec 1, 2010 · Gastroenterology, Urology
Device Facts
Record ID
K102536
Device Name
VITALA CONTINENCE CONTROL DEVICE
Applicant
Convatec, Inc.
Product Code
EZQ · Gastroenterology, Urology
Decision Date
Dec 1, 2010
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 876.5900
Device Class
Class 1
Attributes
Therapeutic
Indications for Use
The VITALA™ Continence Control Device is a single-use device intended to prevent the release of stool from an end colostomy while allowing any flatus from the stoma to be deodorized and released. To be used only with a 1 ¾ in. (45 mm) or 2 ¼ in. (57 mm) ConvaTec NATURA® skin barrier. Not intended for use with ConvaTec Moldable Technology™ skin barriers.
Device Story
Pouchless ostomy device; self-inflating Air Seal with soft foam insert; contacts stoma; retains stool; deodorizes/vents flatus. Used by patients with end colostomies; self-care. Attaches to ConvaTec Natura® skin barrier (45mm or 57mm). Device expands to conform to stoma shape; re-inflates if stoma retracts. Includes expandable container for stool collection during removal. Single-use. Wear time up to 12 hours daily. Benefits patient by restoring continence and managing stoma output without traditional pouching systems.
Clinical Evidence
Two non-randomized, open-label, multi-center studies. Study 1 (n=78): assessed 12-hour wear; 86.9% of subjects rated continence restoration as good/very good; AE rate 0.01/patient/day; no harmful changes to microflora or stoma vascularity (SO2). Study 2 (n=27): assessed 12-hour wear with convex products; 64% rated continence restoration as good/very good; AE rate 0.02/patient/day; no adverse impact on stoma vascularity or oxygen saturation. Evidence supports safety and effectiveness for 12-hour wear and convex product compatibility.
Technological Characteristics
Non-invasive ostomy accessory. Materials: soft foam insert, polypropylene deflation shield. Principle: self-inflating air seal with low-pressure stoma contact. Form factor: pouchless, compatible with 45mm/57mm Natura® skin barriers. Single-use. No electronic components or software.
Indications for Use
Indicated for individuals with end colostomies (at least 12 weeks post-surgery) with formed or semi-formed effluent. Contraindicated for patients with history of chronic liquid stool, stoma protrusion >2 cm (supine), or those requiring ConvaTec Moldable Technology™ skin barriers.
{0}------------------------------------------------
# 102536 ા of 5
# DEC 1 2010
## 510(k) SUMMARY
| Subject Device: | VITALA™ Continence Control Device |
|---------------------------------|-----------------------------------------------------------------------------------------------------|
| Date Prepared: | November 29, 2010 |
| Applicant: | ConvaTec Inc.<br>200 Headquarters Park Drive<br>Skillman, New Jersey 08558 |
| Contact: | Charles Ryan<br>Associate Director, US Regulatory Affairs<br>Tel: 908-904-2541<br>Fax: 908-904-2235 |
| Device Trade Name: | Vitala™ Continence Control Device |
| Classification Name: | Ostomy Pouch and Accessory (ref. 21 CFR 876.5900;<br>Product Code EZQ) |
| Device Class: | Class I |
| Predicate Device Trade Name: | Vitala™ Continence Control Device |
| Classification Name: | Ostomy Pouch and Accessory (ref. 21 CFR 876.5900; Product Code EZQ) |
| Device Class: | Class I |
| 510(k) Substantial Equivalence: | K083785 – determined substantially equivalent on<br>April 2, 2010 |
# DEVICE DESCRIPTION
The Vitala™ Continence Control Device is a pouchless ostomy device consisting of a self-inflating Air Seal which contacts a stoma and is held against the stoma with a low pressure, allowing flatus to be deodorized and vented while retaining stool. The Air Seal contains a soft foam insert that expands to fill the Air Seal, causing the Air Seal to expand with it. As it expands, the Air Seal gently contacts the stoma and conforms to the
{1}------------------------------------------------
K102536
pg 2 of 5
shape of the stoma, and is held against the stoma with a low pressure. The Air Seal will re-inflate to remain in contact with the stoma if the stoma retracts or moves away from the Air Seal.
The Vitala™ Continence Control Device also includes an expandable container to collect stool during removal of the device. This single use device is designed to be used only with a 1 ½" (45mm) or 2 ¼" (57mm) ConvaTec Natura® skin barrier, and will accommodate a range of stoma diameters.
The Vitala™ Continence Control Device is indicated for individuals with end colostomies. The device is not intended for use until the abdomen and peristomal area have fully healed from bowel surgery (typically 6-12 weeks post surgery), or for use with a stoma protrusion greater than 2 cm (when lying down). The device should also not be used in individuals with end colostomies with a history of chronic liquid stool. ConvaTec Moldable Technology™ skin barriers should not be used with the Vitala™ device.
This 510(k) notification concerns modification of the labeling for the Vitala™ Continence Control Device to allow an expanded wear time of up to 12 hours per day for the device as well as expanded compatibility with ConvaTec Natura® convex products. Otherwise, the design, materials, and manufacture of the device remain unchanged from its description in 510(k) Premarket Notification K083785, except that its deflation shield is now made from polypropylene.
### INDICATIONS FOR USE
The VITALA™ Continence Control Device is a single-use device intended to prevent the release of stool from an end colostomy while allowing any flatus from the stoma to be deodorized and released.
To be used only with a 1 ¾ in. (45 mm) or 2 ¼ in. (57 mm) ConvaTec NATURA® skin barrier. Not intended for use with ConvaTec Moldable Technology™ skin barriers.
### CLINICAL SUMMARY .
ConvaTec has performed two clinical studies to assess the safety and effectiveness of the Vitala™ Continence Control Device with an extended wear time of up to 12 hours per day as well as its compatibility with ConvaTec Natura® convex products.
### Clinical Study #1
A non-randomized, open-label, multi-center, multi-national (conducted in the USA and Europe) clinical study was initiated on April 17, 2009 and completed on January 16, 2010.
The planned methodology was to enroll 75 subjects with an end colostomy of at least 12 weeks duration with formed or semi-formed effluent, who had the ability to wear a size 45mm or 57mm ConvaTec Natura® skin barrier flange, and a
{2}------------------------------------------------
K102536
pg 3 of 5
stoma that protruded no more than 2cm at rest (supine/on the back), as well as the ability to do complete self-care.
The primary objective of this clinical study was to assess safety during 12 hours of Vitala™ device wear by measuring the frequency of adverse events (AEs) related to stoma (including gastro-intestinal (GI), stomal and surrounding skin events), microbiology profile and stomal vascularity.
Seventy-eight subjects were enrolled in this study across study centers in the USA and Europe. Thirty-three subjects (42.3%) either withdrew or were discontinued from the study while 45 subjects (57.7%) completed the study per protocol. A total of 66 subjects wore the Vitala™ device.
Subjects in general rated the Vitala™ device as good or very good in its ability to restore continence (86.9%).
Overall, the rate of AEs during the Usual Stage (where subjects used their usual pouch system) and the Vitala™ Stage was identified at 0.01 per patient per day. Nausea/vomiting/diarrhea were the most commonly reported AEs (16 subjects) followed by abdominal pain (7 subjects) and constipation (5 subjects). Most AEs were mild or moderate in nature; however, there were 27 severe or very severe AEs. of which two were possibly related to the Vitala™ device.
Microbiology results showed that baseline evaluations established the presence of normal microflora and common microbial intestinal toxins. No obvious or harmful changes to the normal flora were noted when samples obtained during the Vitala™ Stage were compared to baseline samples. No aberrant flora were noted in the samples collected for GI events.
Stoma vascularity results showed that there was no significant difference in mean oxygen saturation (SO2) values. There was also no evidence of the systematic development of hypoxic regions in subjects who completed the study.
Overall, results from this study indicate that the Vitala™ device is safe and effective at restoring continence when worn up to 12 hours daily.
#### Clinical Study #2
A non-randomized, open-label, multi-center clinical study was conducted in the USA. The study was initiated on February 3, 2010 and completed on April 6, 2010, with primary objective to assess the safety of the Vitala™ Continence Control Device with 45mm and 57mm sizes of ConvaTec Natura® convex products during 12 hours of daily wear. Approximately 15 subjects who had been using some form of convex products and 10 subjects who did not normally use convexity were to be enrolled in this study.
{3}------------------------------------------------
K102536
pg. 4 of 5
The planned methodology was to enroll subjects with an end colostomy of at least 12 weeks duration with formed or semi-formed effluent, current users of convex skin barriers or convex inserts (enrollment targeted 15 convex users and 10 nonconvex users), willingness to wear a ConvaTec Natura® convex product in 45mm or 57mm size with a stoma opening size from 13mm up to 50mm, a stoma that protruded no more than 2cm at rest (supine / lying down on the back) and an ability to do complete self-care.
Twenty-seven subjects were enrolled in this study in the USA. Fifteen subjects who were convex users at baseline and 12 subjects who were non-convex users at baseline were enrolled into the study. Twenty-three subjects (85.2%) completed the study while four subjects (14.8%) discontinued from the study.
Subjects in general rated the VitalaTM device as "good" or "very good" in its ability to restore continence (64%).
Overall, the rate of adverse events (AEs) during the Convex Stage (where subjects used ConvaTec Natura® convex products prior to use of the Vitala™ device) was 0.03 and during the Vitala™ Stage it was identified at 0.02 per patient per day. Nausea/vomiting/diarrhea were the most commonly reported AEs (4 subjects) followed by bleed/bruise (trauma) to stoma wound, constipation and loose stool (3 subjects each). Most AEs were mild or moderate in nature and there was only one very severe AE, which was not considered to be related to the study treatment.
Stoma vascularity results provided no evidence of any changes in stoma and peristomal skin oxygen saturation (SO2) or the development of hypoxic regions in the stoma and hyperoxic regions in peristomal skin as a result of wearing the Vitala™ device with convex products.
Safety results showed no Vitala™ device related serious adverse events (SAEs) and no abnormal findings during the VitalaTM Stage. Stoma vascularity results provided no evidence of any changes in stoma and peristomal skin SO2 or the development of hypoxic regions in the stoma and hyperoxic regions in peristomal skin as a result of wearing the Vitala™ device with convex products.
Overall, results from this study indicate that the Vitala™ device is safe and effective at restoring continence when worn up to 12 hours with convex products.
#### OVERALL CONCLUSION
There are no significant differences in the intended use between the subject and predicate Vitala™ Continence Control Devices. The Vitala™ device is non-invasive to the stoma, and has demonstrated substantial equivalence as well as safety and effectiveness through use in clinical studies, microbiology studies, and vascularity testing of the stoma. The design, materials, and manufacture of the device remain unchanged from how it was
{4}------------------------------------------------
K102536
pg 5 of 5
described in 510(k) Premarket Notification K083785, except that its Deflation Shield is now made from polypropylene.
Based on the evidence provided, we propose that Vitala™ Continence Control Device can be used safely and effectively for individuals with end colostomies to prevent the release of stool from an end colostomy, for a wear time of up to twelve hours per day as well as with ConvaTec Natura® convex products.
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002
Mr. Charles Ryan Associate Director, U.S. Regulatory Affairs ConvaTec. Inc. 200 Headquarters Park Drive SKILLMAN NJ 08558 ·
DEC 1 2010
Re: K102536
Trade/Device Name: VITALA Continence Control Device Regulation Number: 21 CFR 8876.5900 Regulation Name: Ostomy pouch and accessories Regulatory Class: I Product Code: EZQ Dated: September 1, 2010 Received: September 3, 2010
Dear Mr. Ryan:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related
{6}------------------------------------------------
#### Page 2
adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Hukert Lemur MD
Herbert P. Lerner, M.D., Director (Acting) Division of Reproductive, Gastro-Renal and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health
## Enclosure
{7}------------------------------------------------
## Indications For Use
510(k) Number (if known): Not Yet Assigned
K102536
DEC 1 2010
Device Name: VITALA™ Continence Control Device
Indications For Use:
The VITALA™ Continence Control Device is a single-use device intended to prevent the release of stool from an end colostomy while allowing any flatus from the stoma to be deodorized and released.
To be used only with a 1 ¾ in. (45 mm) or 2 ¼ in. (57 mm) ConvaTec NATURA® skin barrier. Not intended for use with ConvaTec Moldable Technology™ skin barriers.
Prescription Use (21 CFR 801 Subpart D) AND/OR
Over the Counter Use XX (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
| (Division Sign-Off)<br>Division of Reproductive, Gastro-Renal, and<br>Urological Devices | |
|------------------------------------------------------------------------------------------|---------|
| 510(k) Number | K102536 |
Page 1 of _______ConvaTec Inc.
.
:
:
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.