← Product Code [DQA](/productcode/DQA) · K102350

# PULSE OXIMETER (K102350)

_Nonin Medical, Inc. · DQA · Dec 22, 2010 · Cardiovascular · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K102350

## Device Facts

- **Applicant:** Nonin Medical, Inc.
- **Product Code:** [DQA](/productcode/DQA.md)
- **Decision Date:** Dec 22, 2010
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 870.2700
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular
- **Attributes:** Pediatric

## Indications for Use

Nonin's Model 3150 WristOx2 Pulse Oximeter is a small wrist-worn device indicated for use in measuring, displaying, and storing functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patients. It is intended for spot-checking and / or data collection and recording of patients who are well or poorly perfused. The intended use environments are sleep and pulmonary rehab labs, surgical recovery, critical care, emergency room, long-term care, home use and mobile units.

## Device Story

Wrist-worn pulse oximeter; collects SpO2 and pulse rate via external sensor. Features motion artifact detection; internal memory for data storage; Bluetooth wireless or wired connectivity. Used in clinical settings (hospitals, sleep labs, rehab, ER) and home environments. Operated by clinicians or patients. Data transmitted to telemedicine systems or nVISION Data Management Software for review. Assists healthcare providers in monitoring patient oxygenation status; supports clinical decision-making through long/short-term data collection.

## Clinical Evidence

Bench and clinical testing performed to demonstrate compliance with ISO 9919:2005 (SpO2 accuracy), IEC 60601-1:1998, and ISO 10993-1:2003 (biocompatibility).

## Technological Characteristics

Wrist-worn pulse oximeter; Bluetooth 2.0 wireless communication; STLC2500C HCI transceiver; LPC2138FHN64/01 ARM7 microcontroller; t.Blue Bluetooth Stack. Automatic transmit power switching (Class 1/Class 2). Wired and wireless connectivity. Biocompatible materials per ISO 10993-1.

## Regulatory Identification

An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. It may be used alone or in conjunction with a fiberoptic oximeter catheter.

## Predicate Devices

- Nonin's Model 3100 WristOx ([K102350](/device/K102350.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K102350

DEC 2 2 2010

## 510(k) Summary

Submitter: Nonin Medical, Inc. Contact Person: Lori M. Mitchell Clinical/Regulatory Specialist Nonin Medical. Inc. 13700 1st Ave. North Plymouth, MN 55441-5443 Date Prepared: August 18, 2010 Trade Name: Model 3150 WristOx2 Classification Name: and Number: Class II, 21 CFR 870.2700 Product Code: DQA Predicate Device(s): This submission demonstrates that the modified Model 3150 WristOx, is substantially equivalent to Nonin's Model 3100 WristOx® based on clinical, performance and safety testing. Validation test results do not raise new questions of safety and effectiveness when compared to the legally marketed devices. Device Description: Model 3150 is a wrist-worn device with memory for patient data collection and Bluetooth wireless communication capability. The device is a simple-touse pulse oximeter for both long and short term measurements. The device can be integrated into a telemedicine system, interfaced to other health data collection systems through the wireless connection, or used with Nonin's nVISION® Data Management Software K033307. The basic functions of the Model 3150 with an external sensor will be: ■ Measurement of SpO2 and pulse rate, . Motion artifact detection, . Collection and storage of data, and Communication via a wired connection and / or Bluetooth wireless connection. Technical Summary of the Bluetooth Module

{1}------------------------------------------------

| Bluetooth 2.0 is an embedded module communicating over the Serial Port. It utilizes a STLC2500C HCI Bluetooth transceiver and a LPC2138FHN64/01 ARM7 microcontroller running the t.Blue Bluetooth Stack. The module has on-board connectors that allow it to communicate to an oximeter device microcontroller either via hardware or software asynchronous serial communication interface.              The module is designed to automatically switch the output transmit power between Bluetooth Class 1 (16 dBm) and Bluetooth Class 2 (4 dBm), conserving battery life and reducing unnecessary RF emissions. |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended Use:                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      | Nonin's Model 3150 WristOx2 Pulse Oximeter is a small wrist-worn device indicated for use in measuring, displaying, and storing functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patients. It is intended for spot-checking and / or data collection and recording of patients who are well or poorly perfused. The intended use environments are sleep and pulmonary rehab labs, surgical recovery, critical care, emergency room, long-term care, home use and mobile units. |
| Functional and<br>Safety Testing:                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  | Nonin's Model 3150 WristOx2 pulse oximeter has successfully undergone both bench and clinical testing in order to demonstrate that it meets the requirements of ISO 9919:2005 Clause 50 Accuracy of Operating Data, Clause 102 section 102.2 Labeling, and IEC 60601-1:1998 (ISO 10993-1:2003) Clause 48 Biocompatibility.                                                                                                                                                                                                     |
| Conclusion:                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | This submission demonstrates that the modified Model 3150 WristOx2 is substantially equivalent to Nonin's Model 3100 WristOx® based on clinical, performance and safety testing. Validation test results do not raise new questions of safety and effectiveness when compared to the legally marketed devices.                                                                                                                                                                                                                 |

and the comments of the comments of

:

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" arranged around the perimeter. Inside the circle is a stylized image of an eagle with its wings spread, symbolizing the department's mission to protect the health of all Americans.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002

Ms. Lori M. Mitchell Nonin Medical, Incorporated 13700 15t Avenue North Plymouth, Minnesota 55441-5443

DEC. 2 2 20:0

Re: K102350

> Trade/Device Name: Model 3150 WristOx2 Pulse Oximeter Regulation Number: 21 CFR 870.2700 Regulation Name: Oximeter Regulatory Class: II Product Code: DQA Dated: December 14, 2010 Received: December 15, 2010

Dear Ms. Mitchell:

.. ...

・・

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

Page 2- Ms. Mitchell

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to

http://www.fda.gov/AboutFDA/CentersQffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely vours.

Wh for

nthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

DEC 2 2 2010

| 510(k) Number (if known) | K102350                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Name              | Model 3150 WristOx2 Pulse oximeter                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
| Indications for Use      | The Nonin Model 3100 WristOx <sup>TM</sup> Pulse Oximeter is a small, wrist-worn device indicated for use is measuring, displaying and storing functional oxygen saturation of arterial hemoglobin (Sp02) and pulse rate. It may be used for spot-checking and/or data collection and recording of adult and pediatric patients during both no motion and motion conditions, and for patients who are well or poorly perfused. The intended use environments are hospitals, medical facilities, ambulatory, subacute, sleep study environments, and mobile units. |

Prescription Use (Part 21 CFR 801 Subpart D)

.;

Over-The-Counter Use _________________________________________________________________________________________________________________________________________________________ (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of GDRH, Office of Device Evaluation (ODE)

(Division Sign-Off) Division of Anesthesiology, General Hospltal Infection Control, Dental Devices

510(k) Number: acl 02 B o 0

---

**Source:** [https://fda-staging.innolitics.com/device/K102350](https://fda-staging.innolitics.com/device/K102350)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com