# JET-X BAR SYSTEM CLAMPS AND POSTS REPROCESSING (K100795)

_Smith & Nephew, Inc. · KTT · Sep 2, 2010 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K100795

## Device Facts

- **Applicant:** Smith & Nephew, Inc.
- **Product Code:** [KTT](/productcode/KTT.md)
- **Decision Date:** Sep 2, 2010
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3030
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic, Pediatric

## Indications for Use

Jet-X External Fixation System components are intended to be used on adults or pediatric patients as required and are intended to be used for post-traumatic joint contracture which has resulted in loss of range of motion; fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction; open and closed fracture fixation; pseudoarthrosis of long bones; correction of bony or soft tissue deformities; correction of segmental bony or soft tissue defects; joint arthrodesis; infected fractures or nonunions; mini external fixator systems are indicated for the management of comminuted intra-articular fractures of the distal radius.

## Device Story

Jet-X Bar System Clamps and Posts are orthopedic external fixation accessories used for bone fracture management and reconstructive/corrective surgery. Devices are manufactured from stainless steel, aluminum, and titanium alloys. They function as mechanical components to provide rigidity and stability when used with pins, wires, and bars. This notification specifically covers the reprocessing of these components. The devices are used by surgeons in clinical settings to stabilize bone segments or joints. The output is a stable mechanical construct that facilitates bone healing or deformity correction. No software or algorithms are involved.

## Clinical Evidence

No clinical data was required to support the safety and effectiveness of the subject devices. Evidence is based on bench testing, including construct fatigue testing to investigate the effects of reprocessing on bar clamps and bar-to-pin clamps, as well as validation of steam sterilization and cleaning processes.

## Technological Characteristics

Constructed from stainless steel, aluminum, and titanium alloys. Mechanical design provides rigidity and stability for external fixation. Components include various clamps (Freedom, Mini Freedom, Quick, Mini Quick, Ankle) and posts. Sterilization is achieved via validated steam sterilization processes. No software, electronics, or energy sources are utilized.

## Regulatory Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- External Fixation Accessories ([K031181](/device/K031181.md))
- Jet-X Bar Clamps and Pin Clamps - Non-magnetic/MR Safe ([K042312](/device/K042312.md))
- Jet-X Bar System Clamps, Bars and Posts - MR Conditional ([K072212](/device/K072212.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

100795

AKy of. Sec
plan

We are smith&nephew

| Submitted by:                                | Smith & Nephew, Inc.<br>Orthopaedic Division<br>1450 East Brooks Road<br>Memphis, Tennessee 38116         | 0 2 2018 |
|----------------------------------------------|-----------------------------------------------------------------------------------------------------------|----------|
| Date of Summary:                             | July 19, 2010                                                                                             |          |
| Contact Person and Address:                  | Shereen Myers, Regulatory Affairs Specialist<br>F (901) 566-7075 ·<br>T (901) 399-6325                    |          |
| Name of Device:<br>Common Name:              | Smith & Nephew, Inc. Jet-X Bar System Clamps and Posts -<br>Reprocessing<br>External Fixation Accessories |          |
| Device Classification Name and<br>Reference: | Single/multiple component metallic bone fixation appliances<br>and accessories, 21 CFR 888.3030, Class II |          |
| Device Class:<br>Panel Code:                 | Class II<br>Orthopaedics/87                                                                               |          |
| Product Code:                                | KTT                                                                                                       |          |

### Device Description

Subject of this Traditional 510(k) premarket notification is the Reprocessed Jet-X Clamps. The subject reprocessed Jet-X clamps are specially designed components used in the management of bone fractures and reconstructive, as well as corrective, orthopedic surgery. The devices have been manufactured from stainless steel, aluminum and titanium alloys and have been designed to allow for the appropriate amount of rigidity and stability. Components of this premarket notification include:

- Freedom Clamp, Bar to Pin Clamps .
- Freedom Clamp, Bar to Bar Clamps .
- Freedom Clamp, Bar to Ring Clamps ●
- Mini Freedom Clamp, Bar to Pin Clamps .
- Ouick Clamp, Bar to Pin Clamps .
- Mini Quick Clamp, Bar to Pin Clamps .
- Pin Clamps, 4 and 6 holes .
- Freedom Post .
- Freedom Ankle Clamp .
- Mini Double Pin Clamp with Ball Joint .

These devices are used with existing components such as pins, wires, bars and other external fixation devices cleared in previous premarket notifications.

## Technological Characteristics

rechnological Charlotteners that the Jet-X Bar System is capable of withstanding A revew of the mechanical add thinks. Including after reprocessing. The following mechanical testing of the Jet-X clamps and posts was performed:

- Construct fatigue testing investigate reprocessing of the bar clamp .
- Construct fatigue testing to investigate reprocessing of the bar to pin clamps .
- Fatigue testing to investigate reprocessing of the bar to pin clamps .
- Validation of steam sterilization process of Jet-X Bar System devices .
- validation of or otbarn evening process of Jet-X Bar System devices

\$\rho.lf_2^{\frac{\pi}{\pi}}\$

{1}------------------------------------------------

A review of this testing has demonstrated that there are no new issues related to the safety and effectiveness of the subject devices. In addition, the principle of operation of these reprocessed devices very similar to that of the predicates. There are no changes in intended use, performance specifications or method of operation. The reprocessed devices utilize similar designs, the same materials and technological characteristics when compared to the predicate devices. Clinical data was not needed to support the safety and effectiveness of the subject devices.

#### Intended Use

Jet-X External Fixation System components are intended to be used on adults or pediatric patients as required and are intended to be used for post-traumatic joint contracture which has resulted in loss of range of motion; fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction; open and closed fracture fixation; pseudoarthrosis of long bones; correction of bony or soft tissue deformities; correction of segmental bony or soft tissue defects; joint arthrodesis; infected fractures or nonunions; mini external fixator systems are indicated for the management of comminuted intra-articular fractures of the distal radius.

#### Substantial Equivalence Information

The substantial equivalence of the Jet-X Bar System Clamps and Posts for Reprocessing is based on its similarities in indications for use, design features, operational principles, and material composition to the following cleared premarket notifications:

| Manufacturer        | Description                                                  | Submission Number | Clearance Date |
|---------------------|--------------------------------------------------------------|-------------------|----------------|
| Smith & Nephew, Inc | External Fixation Accessories                                | K031181           | 06/14/2003     |
| Smith & Nephew, Inc | Jet-X Bar Clamps and Pin<br>Clamps - Non-magnetic/MR<br>Safe | K042312           | 09/24/2004     |
| Smith & Nephew, Inc | Jet-X Bar System Clamps, Bars<br>and Posts - MR Conditional  | K072212           | 03/07/2008     |

#### Conclusion

Conclusion.
As previously noted, this Traditional 510(k) Premarket Notification is being submitted to request As previously holo read of Jet-X Bar System Clamps and Posts. Based on the similarities to the ecoduries to the Riprocessing see of the mechanical testing performed, the devices are substantially equivalent to above predicate external fixation systems.

552
p. 2 of 2

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with its wings spread, and the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circle around the eagle. The logo is black and white and appears to be a simple, clean design. The eagle is facing to the left.

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002

Smith and Nephew, Inc. % Ms. Shereen Myers Regulatory Affairs Specialist 1450 Brooks Road Memphis, Tennessee 38116

SEP 0 2 2013

Re: K100795

Trade/Device Name: Jet-X Bar System Clamps and Posts - Reprocessing Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: II Product Code: KTT Dated: August 25, 2010 Received: August 26, 2010

Dear Ms. Myers:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical

{3}------------------------------------------------

## Page 2 - Ms. Shereen Myers

device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours

Mark N. Melkers Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

# Premarket Notification Indications for Use Statement

02 2010

510(k) Number (if known): _/00

Jet-X Bar System Clamps and Posts - Reprocessing Device Name:

Indications for Use:

Jet-X External Fixation System components are intended to be used on adults or pediatric patients as required and are intended to be used for post-traumatic joint contracture which has resulted in loss of range of motion; fractures and disease which generally may result in joint contractures or loss of range of motion and fractures requiring distraction; open and closed fracture fixation; pseudoarthrosis of long bones; correction of bony or soft tissue deformities; correction of segmental bony or soft tissue defects; joint arthrodesis; infected fractures or nonunions; mini external fixator systems are indicated for the management of comminuted intraarticular fractures of the distal radius.

AND/OR Prescription Use _X__ (Part 21 CFR 801.109) .

Over-the-Counter Use (Optional Format 1-2-96)

(PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Oarlare Buelur for JRF
(Division Sign Off)

(Division Sign-Off)
Division of Surgical, Orthopedic,
and Restorative Devices

510(k) Number K100795

v.lofl

Ai

---

**Source:** [https://fda-staging.innolitics.com/device/K100795](https://fda-staging.innolitics.com/device/K100795)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com