← Product Code [MOS](/productcode/MOS) · K100113

# VANGUARD BREAST MRI AUXILIARY TABLE WITH 16 CHANNEL COIL ARRAY FOR GE 3T MRI SYSTEM, MODEL 4000451-51 (K100113)

_Sentinelle Medical, Inc. · MOS · Apr 22, 2010 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K100113

## Device Facts

- **Applicant:** Sentinelle Medical, Inc.
- **Product Code:** [MOS](/productcode/MOS.md)
- **Decision Date:** Apr 22, 2010
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 892.1000
- **Device Class:** Class 2
- **Review Panel:** Radiology

## Indications for Use

The Sentinelle Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE 1.5T/3T MRI Systems is an open, receive only breast coil designed to provide magnetic resonance images of breast anatomy when used in conjunction with a Magnetic Resonance Scanner. These images can be interpreted by a trained physician. When used with a sterile plate, the device permits access to the breast anatomy for biopsy and localization procedures that can be performed by a trained physician.

## Device Story

Vanguard Breast MRI Auxiliary Table/Tabletop is a receive-only phased array coil system for 1.5T/3T GE MRI scanners. Device supports patient, immobilizes breast via compression plates, and provides access for interventional guidance (e.g., biopsy). Input: RF emissions from nuclei excited by MRI scanner. Transformation: Passive collection of RF signals via 8 or 16-channel phased array coil elements. Output: Enhanced signal-to-noise ratio (SNR) and image resolution for MRI reconstruction. Used in clinical imaging settings by radiologists/physicians. Compression system includes interchangeable fenestrated plates for needle access. Benefits: Improved image detail and faster acquisition via parallel imaging; facilitates minimally invasive breast interventions.

## Clinical Evidence

No clinical data provided. Substantial equivalence is based on bench testing and technological comparison to the predicate device.

## Technological Characteristics

Receive-only phased array MRI coil; 8 or 16-channel configurations. Rigid, fluid-resistant, fire-retardant housing. Includes table base/tabletop, compression frames, and fenestrated plates. Compatible with GE 1.5T/3T MRI systems. Passive RF signal collection. No active software algorithms; hardware-based signal acquisition.

## Regulatory Identification

A magnetic resonance diagnostic device is intended for general diagnostic use to present images which reflect the spatial distribution and/or magnetic resonance spectra which reflect frequency and distribution of nuclei exhibiting nuclear magnetic resonance. Other physical parameters derived from the images and/or spectra may also be produced. The device includes hydrogen-1 (proton) imaging, sodium-23 imaging, hydrogen-1 spectroscopy, phosphorus-31 spectroscopy, and chemical shift imaging (preserving simultaneous frequency and spatial information).

## Special Controls

*Classification.* Class II (special controls). A magnetic resonance imaging disposable kit intended for use with a magnetic resonance diagnostic device only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

## Predicate Devices

- Vanguard Breast MRI Auxiliary Table/Tabletop ([K060873](/device/K060873.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

KI00113

Image /page/0/Picture/1 description: The image shows the logo for Sentinelle Medical. The logo consists of a geometric shape on the left and the words "sentinelle MEDICAL" on the right. The word "sentinelle" is in a larger font than the word "MEDICAL".

510(k) Premarket Notification Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16Ch Coil Array for 1.5T/3T MRI Systems Submitter: Sentinelle Medical Inc. March 25, 2010

### 7. 510(k) Summary

## APR 2 2 2010

# 510(k) Summary of Safety and Effectiveness for: Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE 1.5T/3T MRI Systems

#### I. Manufacturer

Sentinelle Medical Inc. 555 Richmond Street West, Suite 800, Toronto, ON Canada M5V 3B1

### II. Contact Person

Joan Medley Director, Regulatory and Quality Tel: (647) 258-3607 Fax: (416) 594-9696

#### III. Product Name/Classification Name

| Product Name:        | Vanguard Breast 8/16 Channel, 1.5T/3T MRI Systems |
|----------------------|---------------------------------------------------|
| Common Name:         | Vanguard Breast MRI System                        |
| Classification Name: | Magnetic Resonance Imaging Accessory              |
|                      | Class II as described in CFR 21 892.1075          |
| Product Code:        | MOS                                               |

#### IV. Date Prepared March 25, 2010

#### V. Device Description

The Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE

1.5T/3T MRI Systems is a receive-only MRI imaging coil and interventional system for the breast anatomy. The system consists of a table base and/or a tabletop supports the patient, the imaging coils and means for modest compression/immobilization of the breast, as well as a means of enabling interventional device guidance. The table base (optional) is used to support and transport the tabletop.

The tabletop, like other breast coils provides an aperture to admit the breasts. A corresponding aperture in the table base maximizes physician access to the breast(s) when the tabletop is at the home position. This table aperture is useful for guidance of interventional devices (such as biopsy needles), especially when it is desired to perform a biopsy from a medial approach.

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image contains the logo for Sentinelle Medical. The logo consists of a geometric shape on the left and the words "sentinelle MEDICAL" on the right. The word "sentinelle" is in a larger font than the word "MEDICAL". The geometric shape is a complex design of intersecting lines.

510(k) Premarket Notification Vanguard Breast MRI Auxiliary Table/Tabletop with &16Ch Coil Array for 1.5T/3T MRI Systems Submitter: Sentinelle Medical Inc. March 25, 2010

The tabletop's compression system facilitates immobilization of the breast for imaging and interventional procedures and serves to hold the individual imaging coils in proximity to the breast(s).

Compression plates provided with the system are held in compression frames which may be positioned in the left-right and anterior-posterior directions and fixed in place to gently immobilize one or both breasts for interventional procedures.

When performing a stereotactic interventional procedure (such as biopsy or wire localization), one or more compression plates may be interchanged for a sterile, single use, disposable fenestrated plate cleared under FDA 510(k) number: K060873. The fenestrated plate has apertures that permit the physician to access the breast for intervention, while minimizing tissue motion.

When performing biopsy and/or imaging of a single breast, the system may be used with two compression plates immobilizing that breast. The contralateral breast support prevents the contralateral breast from interfering with medial-approach interventions.

When imaging both breasts, a medial coil element is used between the breasts in conjunction with two lateral coils. The tabletop's receive-only coil system acts to passively collect RF emissions from the nuclei excited by the MRI. The function of the tabletop is substantially equivalent to predicate devices used for breast MRI maging and intervention, including our legally marketed device 510(K) Number: K060873.

The Vanguard phased array coil set consists of 8 or 16 RF coil elements in a phased array design. The 16 channel coil array may be interchanged with a 10 or 2-channel coil array. The coil elements and electronics are enclosed in a rigid housing that is resistant to fluid ingress and is fire retardant. The coils are positioned close to the patient's breast during imaging. This receive-only coil is designed to give an improved signal-to-noise ratio, image resolution and image acquisition over that of a standard body coil.

The Sentinelle Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE 1.5T/3T MRI Systems will consist of the following new models:

D Description: Sentinelle Vanguard Breast MRI Auxiliary Tabletop, 3T, 16 Channels

- o Model: 4000451
- Compatibility: General Electric Discovery MR750 3T 0

D Description: Sentinelle Vanguard Breast MRI Auxiliary Tabletop, 1.5T, 16 Channels

- Model: 4000636 0
Sentinelle Medical Inc.

{2}------------------------------------------------

Image /page/2/Picture/0 description: The image shows handwritten text on a white background. The text "K100113" is on the first line, and "Page 3/3" is on the second line. The text appears to be written in a casual, cursive style.

Image /page/2/Picture/1 description: The image shows the logo for Sentinelle Medical. The logo consists of a geometric shape on the left and the words "sentinelle MEDICAL" on the right. The word "sentinelle" is in a larger font than the word "MEDICAL". The geometric shape is a complex design with multiple intersecting lines.

- Compatibility: General Electric Discovery MR450 1.5T and General Electric Optima o MR450w 1.5T
- D Description: Sentinelle Vanguard Breast MRI Auxiliary Tabletop, 3T, 8 Channels
	- Model: 4000700 o
	- Compatibility: General Electric Signa HDxt 3T o
- D Description: Sentinelle Vanguard Breast MRI Auxiliary Table/Tabletop, 1.5T, 8 Channels
	- Model: 4000198 O
	- Compatibility: General Electric Signa 1.5T Systems O

The various coil layout configurations (8/4/2 or 16/10/2) can be found in Appendix VIII.1.

A full description of the system in form and function and the accompanying technical drawings were provided in the Traditional 510(K) cleared in April 2006 under FDA 510(K) Number: K060873.

A representative copy of the Operator's Guide (User Manual) which details the proposed labeling (operating instructions, cautions, warnings, and indications for use) can be found in Appendix V.1.

# VI. Intended Use

The Sentinelle Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE 1.5T/3T MRI Systems is an open, receive only breast coil designed to provide magnetic resonance images of breast anatomy when used in conjunction with a Magnetic Resonance Scanner. These images can be interpreted by a trained physician. When used with a sterile plate, the device permits access to the breast anatomy for biopsy and localization procedures that can be performed by a trained physician.

*Note: The intended use of this modified device, as described in its labeling has not changed as a result of the modifications.

The benefits of the Vanguard 16Ch, receive-only coil includes:

- An increase in the Signal-to-Noise Ratio (improving image detail) .
- . A decrease in imaging acquisition time resulting from enhanced parallel imaging capability

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or bird-like figure with three stylized wing or feather shapes.

#### DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002

Ms. Joan Medley Director, Regulatory and Quality Sentinelle Medical, Inc. 555 Richmend Street West Suite 800, P.O. Box 301 Toronto, Ontario, M5V 3B1 CANADA

APR 2 2 2010

Re: K100113

Trade/Device Name: Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 channel coil array for GE 1.5T/3T MR Systems Regulation Number: 21 CFR 892.1000 Regulation Name: Magnetic resonance diagnostic device Regulatory Class: II Product Code: MOS Dated: March 25, 2010 Received: March 26, 2010

Dear Ms. Medley:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of

{4}------------------------------------------------

medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, perceits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation (21 CLT and Safety at (301) 796 5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office

of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its tolli the (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Donald J. Trump

Donald J. St.Pierre Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

# Indications for Use

### 510(k) Number (if known): k100113

### Device Name: _Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 channel coil array for GE 1.5T/3T MR Systems

Indications for Use:

The Sentinelle Vanguard Breast MRI Auxiliary Table/Tabletop with 8/16 Channel Coil Array for GE 1.5T/3T MRI Systems is designed to provide magnetic resonance images of breast anatomy when used in conjunction with a Magnetic Resonance Scanner. These images can be interpreted by a trained physician. When used with a sterile fenestrated plate, this device permits access to the breast anatomy for biopsy and localization procedures that can be performed by a trained physician.

Prescription Use (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD)

Robert L. Becker

(Division Sign Off) Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety

510(k) Number K100113

Page 1 of

---

**Source:** [https://fda-staging.innolitics.com/device/K100113](https://fda-staging.innolitics.com/device/K100113)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
