The VISTEO digital system is used to provide instant digital images of human oral tissue and teeth without the use of a conventional x-ray film. It is used for diagnosis purpose, by dental practitioners. This is achieved by using the conventional x-ray tube, and placing an electronic sensor in the patient's mouth instead of conventional film. The sensor, upon radiation exposure, automatically captures the images into a computer. The computer, which is not provided by OWANDY, controls all aspects of image acquisition and image display, storage and printing. Additional software (after, and not part of, image capture software) is available on the market. They allow for enhancements such as zoom, controls, image inversion, and pseudo color renditions. The main advantages of this digital imaging system are : - high definition ensuring high-value diagnostics - interface allowing image processing in the PC In no case, it has to be used directly by the patient. So, it is used exclusively in a healthcare specific environment.
Device Story
VISTEO is a digital dental imaging system; replaces conventional X-ray film. Components: hermetically sealed CMOS sensor, 1-meter cable, USB/data box. Operation: sensor placed in patient's mouth; dental X-ray tube emits radiation; sensor captures charge pattern; electronic signals digitized; data transmitted via USB to external computer. Used in clinical environments by dental practitioners. Output: digital images displayed on computer for diagnostic evaluation. Benefits: instant image acquisition, high-definition diagnostics, digital storage/processing. System requires external computer and software for image acquisition, display, and storage.
Clinical Evidence
Bench testing only. No clinical data provided.
Technological Characteristics
Solid-state CMOS imaging sensor; hermetically sealed shell; USB/data box interface; wired connection (1m cable); two sizes (D001: 38.9x24.9x7.4mm; D002: 42.9x30.9x7.4mm); single-use disposable sheath; standard USB connectivity to external PC.
Indications for Use
Indicated for dental radiographic imaging of human oral tissue and teeth in patients requiring routine dental radiography. Used by dental professionals in clinical environments. Not for patient self-use.
Regulatory Classification
Identification
An extraoral source x-ray system is an AC-powered device that produces x-rays and is intended for dental radiographic examination and diagnosis of diseases of the teeth, jaw, and oral structures. The x-ray source (a tube) is located outside the mouth. This generic type of device may include patient and equipment supports and component parts.
{0}------------------------------------------------
VISTEO 510(k)
# 510(K) SUMMARY
## Premarket Notification for VISTEO Device
### K093105
Submitter OWANDY 6 Allee Kepler 77420 Champs sur Marne France Tel : +33 1 64 11 18 18 Fax : +33 1 64 11 18 10
Application correspondent
Jay Mansour 845 Aronson Lake Court Roswell GA 30075 Tel : 678-908-8180 Fax: 678-623-3765
#### Device name
Proprietary name: VISTEO Classification name : Extra oral source X-Ray System accessory Common name : Digital dental imaging device
#### Predicate devices
Manufacturer/Applicant = OWANDY UNIVERSAL-X : K053172
#### Device description
The VISTEO system consists of the following components: the sensor and its cable, a USB/data box, with sensor adapter. The sensor body is made hermitically sealed shell which encapsulates a black and white CMOS chip. The sensor attaches the USB/data box (processing unit) via a 1 meter removable cable.
The sensor, when exposed to radiation, captures image in the form of a charge pattern on its surface (CMOS). The resulting electronic signals are digitised and sent to a computer for image presentation.
According to the 2 different models, there are two possible sizes:
D001 model (size 1): the outer dimensions are approximately 1.5 x 1.0 x 0.3 inches (38,9 x 24,9 x 7,4mm) with rounded edges.
D002 model (size 2): the outer dimensions are approximately 1.7 x 1.2 x 0.3 inches (42.9 x 30.9 x 7,4mm) with rounded edges.
The USB/data box relays the data from to the computer for display. The data box is a 5.4 x 1.8 x 0.7 inches (13.8x 1.8 x 0.7 cm) box with an USB cable connection.
Positioner accessories : 2 bite blocks (bitewing and endo) + 1 aiming ring
OCT 1 8 2010
{1}------------------------------------------------
### OWANDY
#### VISTEO 510(k)
#### Intended use
The VISTEO digital system is used to provide instant digital images of human oral tissue and teeth without the use of a conventional x-ray film. It is used for diagnosis purpose, by dental practitioners.
This is achieved by using the conventional x-ray tube, and placing an electronic sensor in the patient's mouth instead of conventional film.
The sensor, upon radiation exposure, automatically captures the images into a computer.
The computer, which is not provided by OWANDY, controls all aspects of image acquisition and image display, storage and printing.
Additional software (after, and not part of, image capture software) is available on the market. They allow for enhancements such as zoom, controls, image inversion, and pseudo color renditions.
The main advantages of this digital imaging system are :
- high definition ensuring high-value diagnostics
- interface allowing image processing in the PC
In no case, it has to be used directly by the patient. So, it is used exclusively in a healthcare specific environment.
#### Substantial equivalence and technological characteristics
The VISTEO device is substantially equivalent to the UNIVERSAL-X predicate device , legally marketed in the United States (K053172) by OWANDY in 2006.
The VISTEO and the predicate devices are intended to be used with Dental X-ray source, Dental Image Management Application Software and standard computer hardware for the capture, evaluation and storage of high quality digital dental X-ray mages using existing X-ray equipments.
The system and its predicates all consists of a X-ray sensitive solid state imaging array (CCD technology for the predicate, CMOS technology for the VISTEO) installed in the Dental X-ray device in place of the traditional photographic film, connected via cable to digitizing and control electronics which, in turn, interface to a computer via a standard interface. The proposed and predicate devices are intended for patients receiving routine dental radiography, in a clinical environment by dental professionals.
{2}------------------------------------------------
### DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002
OWANDY % Mr. Jay Mansour, MSQA, BE, RAC, LA President Mansour Consulting 845 Aronson Lake Court ROSWELL GA 30075
Re: K093105
OCT 1 8 2010
Trade/Device Name: Visteo Regulation Number: 21 CFR 872.1800 Regulation Name: Extraoral source x-ray system Regulatory Class: II Product Code: EHD Dated: August 23, 2010 Received: August 26, 2010
#### Dear Mr. Mansour:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of
{3}------------------------------------------------
medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
signature
David G. Brown, Ph.D. Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
## Indications for Use Form
OCT 1 8 2010
510(k) Number (if known): K093105
VISTED Device Name:
Indications for Use:
The VISTEO digital system is designed to collect instant images of human oral tissue and teeth without the use of a conventional x-ray film.
It is used with a conventional X-ray tube and a Computer for dental radiographic imaging.
The VISTEO is covered with a single use disposable sheath and positioned in the oral cavity opposite the tooth the dentists wishes to X-Ray.
The dental X-ray tube (which is not part of VISTEO) is pointed at the sensor and activated.
The emitted radiation from the X-ray tube is detected by the sensor and transmitted as a data stream to the computer system that the device is connected to
In no case, it has to be used directly by the patient. So, it is used exclusively in a healthcare specific environment.
Prescription Use ============================================================================================================================================================= (21 CFR 801 Subpart Ci
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD)
Division Sign-Off
Office of In Vitro Diagnostic Device Evaluation and Safety
510[k] K092105
Page 1 of
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.