K092433 · Forth Photonics Hellas SA · HEX · Mar 10, 2011 · Obstetrics/Gynecology
Device Facts
Record ID
K092433
Device Name
DYSIS
Applicant
Forth Photonics Hellas SA
Product Code
HEX · Obstetrics/Gynecology
Decision Date
Mar 10, 2011
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 884.1630
Device Class
Class 2
Attributes
Real-World Evidence
Real-World Evidence
Submission
Device
Sponsor
RWD Sources
RWE Use Summary
Key Tags
K092433 · Mar 10, 2011
DYSIS
Forth Photonics Hellas SA
Retrospective patient clinical data
Retrospective patient data was used to evaluate the performance specifications of the device's Pseudo-Color Imaging (PCI) feature, specifically regarding image registration, acetic acid timing, and PCI value ranges.
Image registration, acetic acid timing errors, and range of PCI values
Indications for Use
DySIS with Pseudo-Color Imaging (PCI) is a digital colposcope designed to image the cervix and lower genital tract under illumination and magnification. Colposcopy is indicated for women with an abnormal Pap smear in order to affirm normality or detect abnormal appearances consistent with neoplasia, often with directed biopsy. The PCI feature is an adjunctive tool for displaying areas of acetowhitening. It is a tool that should NOT be used as a substitute for a thorough colposcopic evaluation.
Device Story
DySIS is a digital colposcope for magnified imaging of the cervix and lower genital tract. It uses LED illumination and a CCD camera to capture high-resolution images and video. The device features Pseudo-Color Imaging (PCI), which processes digital images to create color-coded maps of acetowhitening intensity, duration, and extent. Operated by clinicians in a clinical setting, the device displays images on a color monitor and touch screen. The clinician performs a standard colposcopic exam first, identifying biopsy sites; the PCI feature serves as an adjunctive tool to potentially identify additional sites. The device includes a database for storing patient data and examination records. It does not automate acetowhitening evaluation; clinicians must not cancel biopsy sites based on PCI output. The system benefits patients by providing enhanced visualization and documentation of the colposcopic examination.
Clinical Evidence
No clinical studies were conducted. Evidence is based on bench testing, including thermal output measurements, timing tolerance for acetic acid application, color calibration, and image alignment algorithm validation. Retrospective patient data analysis confirmed the device meets performance specifications for image registration and PCI value ranges but did not demonstrate clinical superiority over conventional colposcopy.
Technological Characteristics
Digital colposcope with LED illumination and CCD sensor. Features include color touch screen, image/video capture, and database storage. Employs an image alignment algorithm to compensate for patient movement. Connectivity includes digital storage and printing. No specific material standards cited.
Indications for Use
Indicated for women with abnormal Pap smears to evaluate the cervix and lower genital tract for neoplasia, often requiring directed biopsy.
Regulatory Classification
Identification
A colposcope is a device designed to permit direct viewing of the tissues of the vagina and cervix by a telescopic system located outside the vagina. It is used to diagnose abnormalities and select areas for biopsy. This generic type of device may include a light source, cables, and component parts.
Special Controls
*Classification.* Class II (special controls). The device, when it is a standard colposcope (or colpomicroscope) that uses only a white light source, does not use filters other than a green filter, does not include image analysis software, and is not smartphone-based, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.
CooperSurgical Digital Colposcopy System (K972630)
Goldway SLC-2000 Digital Video Colposcope Imaging System (K021153)
Submission Summary (Full Text)
{0}------------------------------------------------
# 510(k) summary
# MAR 1 0 2011
Ko92433 pa
#### 1. Submitter Identification
| Submitter | Forth Photonics, Ltd<br>Alba Innovation Centre<br>Livingston, Scotland UK |
|----------------|---------------------------------------------------------------------------|
| Contact Person | Joshua Freeman |
| Phone | +1 781 329 2993 |
| Fax | +1 781 329 2968 |
| Date Prepared | 02/04/2011 |
#### 2. Device Identification
| Name of Device | DySIS |
|------------------------|----------------------------|
| Trade/Proprietary Name | DySIS |
| Common or Usual Name | Digital Colposcope |
| Classification | Colposcope (21CFR884.1630) |
| Product Code | 85HEX |
## 3. Predicate Devices
| Manufacturer | Model | Trade Name | 510(k) |
|-----------------|------------|----------------------------------------------------|---------|
| Welch-Allyn | 88000/8900 | Video Colposcope | K955635 |
| Cooper Surgical | | CooperSurgical Digital Colposcopy System | K972630 |
| Goldway | SLC-2000 | Goldway Digital Video Colposcope Imaging<br>System | K021153 |
The indications for use for Forth Photonics DySIS digital colposcope are substantially equivalent to the indications for use of the predicate devices.
# 4. Executive Summary
DySIS is a digital colposcope intended to provide magnified viewing of the vagina, cervix and external genitalia. DySIS is used to diagnose abnormalities and select areas for biopsy. DySIS acquires, displays and documents high-resolution still and sequentially
{1}------------------------------------------------
K09 2433 page 2 of 5
captured images and videos and provides color-coded mapping of the acetowhitening effect to facilitate assessment and documentation.
#### 5. Device Description
DySIS offers non-patient contact, fully digital and high-resolution imaging of the cervix. The field of view is illuminated by an LED; a CCD camera coupled with the imaging optics provides crisp magnified color images. The images can be viewed on a color monitor and on the color touch screen that provides the means to control the device operation.
DySIS offers digital tools to fully document the colposcopic examination:
- Capturing of images for review, storage and printing, video recording .
- Advanced magnification and imaging .
- Operator's annotation of suspicious sites .
- Color-coded mapping of acetowhitening intensity and duration .
- Database that allows storing and retrieving identification and examination data .
## 6. Indications for Use statement
DySIS with Pseudo-Color Imaging (PCI) is a digital colposcope designed to image the cervix and lower genital tract under illumination and magnification. Colposcopy is indicated for women with an abnormal Pap smear in order to affirm normality or detect abnormal appearances consistent with neoplasia, often with directed biopsy. The PCI feature is an adjunctive tool for displaying areas of acetowhitening. It is a tool that should NOT be used as a substitute for a thorough colposcopic evaluation.
## 7. Comparison to predicate devices
The CooperSurgical, Welch-Allyn and Goldway colposcopes permit magnified viewing of the tissues of the vagina, the cervix and external genitalia to identify atypical sites and select sites to biopsy. The Welch-Allyn and Goldway colposcopes feature viewing exclusively via a monitor, whereas the CooperSurgical colposcope also allows direct viewing. These systems also provide documentation capabilities, such as still image and/or video capture (all three) and reporting of the colposcopic predictions
{2}------------------------------------------------
K092433 page 3 of 5
(CooperSurgical and Goldway) and annotation/measurement tools (CooperSurgical). Further, DySIS offers optional color-coded mapping of acetowhitening by processing digital images, in a way similar to that of other medical devices. The DySIS color-coded mapping feature does not interfere with the view of the cervix during the colposcopic exam. It provides the colposcopist with an alternative representation and enhancement of the images captured during the acetowhitening effect. Specifically, the pseudocolor map depicts the extent, intensity and duration of the acetowhitening effect; however, it is not intended to automate the acetowhitening evaluation.
Use of the PCI feature is NOT a substitute for the conventional colposcopic view. When using the DySIS with Pseudo-Color Imaging (PCI) the clinician must ALWAYS first conduct a thorough colposcopic exam and identify and select areas for biopsy. The clinician may then use the Pseudo-Color Imaging (PCI) feature to (possibly) identify one or more additional biopsy sites, but may NEVER cancel any of the biopsy sites initially identified with the conventional colposcopic view.
DySIS is a fully digital colposcope, integrating a high-resolution CCD sensor, LED illumination and additional options to improve ergonomics and documentation of the colposcopic examination.
The provided technical improvements do not raise any questions of safety or effectiveness.
# 8. Non-Clinical Tests Supporting Substantial Equivalence
DySIS has undergone extensive testing to show substantial equivalence to existing colposcopes. The following tests have been performed:
a) LED temperature: Thermal output was measured on a piece of white paper placed at working distance. The temperature at the middle of the paper was measured with two instruments. The paper did not experience any significant increase in temperature after one hour of continuous exposure.
b) Timing Tolerance: This experiment tested the effect of two delay scenarios. The first, imaging delay, occurs when there is a delay between the time of acetic acid delivery and the start of imaging. The second, acetic acid delay, occurs when imaging is
{3}------------------------------------------------
started before acetic acid delivery. In both cases, differences from AUC values where no delay occurred were small and not statistically significant.
c) Acetic acid concentration: This experiment tested the difference in acetowhitening between 3% and 5% acetic acid solutions. As expected the 5% solution exhibited a more extreme aceto-whitening effect. Overall, the experiment indicated that the DySIS map is capable of accurately depicting the aceto-whitening effect regardless of whether a 3% or 5% acetic acid solution is used.
d) Color Calibration: This tested the effects of moving the calibration test card closer or further than the standard focusing distance of 30 cm. An operator was asked to focus from a random distance between +3 mm from focusing distance. The results indicated that Pixel Value (a function of reflected LED brightness) fell within the desired tolerance band of ±2 from points within this range.
Image Alignment: In order to test the effectiveness of the alignment e) algorithm, which is used to account for small movements during the exam, one cervical image was sequentially distorted ten times. The distortions totaled a 20% change from the original, which is equivalent to 7 mm of actual movement. The algorithm was able to compensate to 0.4 mm, well within the acceptable level.
## 9, Clinical Tests Supporting Substantial Equivalence
No clinical studies were conducted to demonstrate improved clinical performance using the PCI feature.
Test results using patient data indicate that the device meets performance specifications related to image registration, acetic acid timing errors, and range of PCI values.
Importantly, the study using retrospective patient data did not demonstrate that the PCI feature is superior to conventional colposcopy in helping the clinician target sites with suspected CIN for biopsy. Therefore, use of the PCI feature is not a substitute for conventional colposcopy. Consequently, the device is designed so that the clinician must perform a standard colposcopy and identify sites for biopsy before he/she can view the PCI image.
{4}------------------------------------------------
K092433 page 5 of 5
The device labeling clearly states that before viewing the PCI image, the clinician should ALWAYS perform colposcopy and commit to biopsy sites on the basis of the colposcopic evaluation. Labeling also states that colposcopically-directed biopsy sites should NEVER be cancelled on the basis of the PCI image
#### 10. Conclusion
The Forth Photonics DySIS digital colposcope has equivalent indications for use and principles of operation to the referenced predicate devices. The additional features of the DySIS digital colposcope over the predicate devices do not raise any questions of safety and effectiveness. Thus, the DySIS digital colposcope is substantially equivalent to legally marketed colposcopes.
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle.
Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002
Forth Photonics Hellas SA % Ms. Amy Aulwes Vice President Health Policy Associates, Inc. 690 Canton Street. Suite 302 WESTWOOD MA 02090
Re: K092433
Trade Name: DySIS Digital Colposcope Regulation Number: 21 CFR §884.1630 Regulations Name: Colposcope . Regulatory Class: II Product Code: HEX Dated: January 4, 2010 Received: January 5, 2010
MAR 1 0 2719
Dear Ms. Aulwes:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The J general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related
{6}------------------------------------------------
Page 2
adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Hubert Lemmer MD
Herbert P. Lerner, M.D., Director (Acting) Division of Reproductive, Gastro-Renal and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
# Indications for Use
510(k) Number (if known): K092433
#### Device Name: DySIS Digital Colposcope
Indications for Use:
DySIS with Pseudo-Color Imaging (PCI) is a digital colposcope designed to image the cervix and lower genital tract under illumination and magnification. Colposcopy is indicated for women with an abnormal Pap smear in order to affirm normality or detect abnormal appearances consistent with neoplasia, often with directed biopsy.
The PCI feature is an adjunctive tool for displaying areas of acetowhitening. It is a tool that should NOT be used as a substitute for a thorough colposcopic evaluation.
Prescription Use _ X (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Norma J. Perry
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.