CHITOGAUZE,2 IN X 2 IN,8 PLY, 4 IN X 4 IN 8 PLY, 4 IN X 8 IN, 8PLY, 1 IN X 4 IN, 8PLY, CHITOGAUZE, PACKAGING STRIP, 1/2

K092357 · Hem Con Medical Technologies, Inc. · QSY · Aug 25, 2009 · SU

Device Facts

Record IDK092357
Device NameCHITOGAUZE,2 IN X 2 IN,8 PLY, 4 IN X 4 IN 8 PLY, 4 IN X 8 IN, 8PLY, 1 IN X 4 IN, 8PLY, CHITOGAUZE, PACKAGING STRIP, 1/2
ApplicantHem Con Medical Technologies, Inc.
Product CodeQSY · SU
Decision DateAug 25, 2009
DecisionSESE
Submission TypeSpecial
Device ClassClass U
AttributesTherapeutic

Indications for Use

ChitoGauze™ is intended to be a hemostatic wound dressing.

Device Story

ChitoGauze is a hemostatic wound dressing composed of polyester/rayon non-woven gauze coated with chitosan. Chitosan provides hemostatic properties to enhance bleeding control. The device is z-folded, packaged in a peelable foil pouch, and terminally sterilized via gamma irradiation. It is intended for external application to wounds. The device is used by clinicians or patients to stop bleeding; it functions by physical contact with the wound site to promote hemostasis. This specific submission expanded the available dimensional sizes of the previously cleared dressing.

Clinical Evidence

No clinical data was required. Bench testing included biocompatibility per ISO 10993 and antimicrobial effectiveness testing demonstrating log reductions >4.0 for various Gram-positive and Gram-negative microorganisms.

Technological Characteristics

Polyester/rayon non-woven gauze coated with chitosan. Sterilized via gamma irradiation (ISO 11137:2006) to a sterility assurance level (SAL) of 10^-6. Device is a passive, non-electronic, non-implantable wound dressing.

Indications for Use

Indicated for prescription use for external, temporary control of severely bleeding wounds; indicated for over-the-counter use for temporary external control of bleeding of minor wounds, minor cuts, and minor abrasions.

Regulatory Classification

Identification

To temporarily control bleeding and cover external wounds.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logos of the Department of Health & Human Services and the Food and Drug Administration (FDA). The Department of Health & Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the FDA acronym in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text. HemCon Medical Technologies, Inc. c/o Kevin Hawkins Director - Quality & Regulatory 10575 SW Cascade Avenue, Suite 130 Portland, Oregon 97223-4363 July 28, 2023 Re: K092357 Trade/Device Name: ChitoGauze™ Regulatory Class: Unclassified Product Code: QSY Dear Kevin Hawkins: The Food and Drug Administration (FDA) is sending this letter to notify you of an administrative change related to your previous substantial equivalence (SE) determination letter dated August 25, 2009. Specifically, FDA is updating this SE Letter because FDA has better categorized your device technology under product code QSY. Please note that the 510(k) submission was not re-reviewed. For questions regarding this letter please contact Julie Morabito, OHT4: Office of Surgical and Infection Control Devices, 240-402-3839, Julie.Morabito@fda.hhs.gov. > Sincerely. Julie A. Morabito -S Julie Morabito, Ph.D. Assistant Director DHT4B: Division of Infection Control and Plastic Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes representing the department's mission. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" is arranged in a circular fashion around the eagle. Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002 HemCon Medical Technologies, Inc. % Mr. Kevin Hawkins Director - Quality & Regulatory 10575 SW Cascade Avenue, Suite 130 Portland, Oregon 97223 AUG 2 5 2009 Re: K092357 Trade/Device Name: ChitoGauze™ Regulatory Class: Unclassified Product Code: FRO Dated: July 29, 2009 Received: August 5, 2009 Dear Mr. Hawkins: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set {2}------------------------------------------------ # Page 2 - Mr. Kevin Hawkins forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/cdrh/mdr/ for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours. Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ # Indications for Use 510(k) Number (if known): K092357 Device Name: ChitoGauze™ # Indications for Use (Rx): ChitoGauze™ is a hemostatic dressing for the external, temporary control of severely bleeding wounds. : # Indications for Use (OTC): ChitoGauze™ is intended for temporary external use to stop bleeding of minor wounds, minor cuts and minor abrasions. Prescription Use _ × (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use X (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Daniel Krone (Division Sign-Off) Division of Surgical, Orthopedic, and Restorative Devices 510(k) Number K072357 Page 1 of 1 {4}------------------------------------------------ # AUG 2 5 2009 K092357 page 1/3 # Section 6: 510(k) Summary Trade Name: Common Name: Classification Name: Product Code: Predicate Device(s): ChitoGauze™ Wound Dressing Dressing FRO Modification to ChitoGauze™ (K090026) Company Name: Company Address: HemCon Medical Technologies, Inc. 10575 SW Cascade Avenue, Suite 130 Portland, OR 97223 Director - Quality & Regulatory Contact Person: Contact Phone: Contact Fax: Date of Preparation: 29 July 2009 Kevin Hawkins (503)245.1326 (503)245.0459 x114 # Description of the Device: The ChitoGauze dressing is composed of standard polyesterfrayon blend non-woven medical gauze that is coated with chitosan. This submission adds models of various dimensions to the legally marketed four inch by four yard (4" x 4 yds) dressing. ChitoGauze dressings are z-folded and packaged in a peelable foil pouch. The pouched dressing is terminally sterilized with gamma irradiation to a sterility assurance level (SAL) of 10th. The hemostatic properties of chitosan enhance the ability of the medical gauze to control bleeding. ### Intended Use: ChitoGauze™ is intended to be a hemostatic wound dressing. ## Indications for Use (Rx): ChitoGauze is a hemostatic dressing for the external, temporary control of severely bleeding wounds. ### Indications for Use (OTC): ChitoGauze is intended for temporary external use to stop bleeding of minor wounds, minor cuts and minor abrasions. # Technological Characteristics: Changing the dimensional size of the dressing has no effect upon the technological characteristics. {5}------------------------------------------------ K092357 page 2/3 # Non-Clinical Performance Data: ## Biocompatibility Biocompatibility has been demonstrated per ISO 10993. Changing the dimensional size of the dressing has no effect upon the biocompatibility. # Reduction of Microorganisms: An eight-ply version of ChitoGauze™ that represents the smallest product size, was tested for reduction of microorganisms against the following species. The log reduction data demonstrates the level of antibacterial effectiveness. The clinical utility of these results is unknown. | Microorganism | Gram Stain | Log Reduction | |--------------------------------------------|------------|---------------| | Staphylococcus aureus (MRSA) ATCC 33591 | + | >5.0 | | Staphylococcus aureus (MRSA) ATCC BAA-1556 | + | >5.1 | | Staphylococcus epidermidis ATCC 12228 | + | >4.4 | | Pseudomonas aeruginosa ATCC 9027 | - | >5.1 | | Enterococcus faecalis (VRE) ATCC 51299 | + | >5.4 | | Acinetobacter baumanii ATCC 15308 | - | >5.2 | | Citrobacter freundii ATCC 8090 | - | >5.2 | | Enterobacter cloacae ATCC 13047 | - | >4.9 | | Streptococcus mutans ATCC 25175 | + | >4.7 | | Streptococcus pneumoniae ATCC 10015 | + | >5.4 | | Escherichia coli ATCC 8739 | - | >4.9 | | Klebsiella pneumoniae ATCC 4352 | - | >5.2 | | Streptococcus pyogenes ATCC 19615 | + | 5.0 | | Salmonella choleraesius ATCC 10708 | - | >4.6 | | Stenotrophomonas maltophilia ATCC 12714 | - | >5.1 | | Citrobacter koseri ATCC 25408 | - | >4.7 | | Proteus mirabilis ATCC 4630 | - | >5.0 | | Proteus vulgaris ATCC 12454 | - | >4.6 | | Moraxella catarrhalis ATCC 8193 | - | >4.9 | | Clostridium difficile ATCC 9689 | + | >5.0 | | Shigella species ATCC 11126 | - | >4.3 | | Micrococcus luteus ATCC 49732 | + | >5.0 | | Vibrio cholerae ATCC 11558 | - | >4.0 | | Enterobacter aerogenes ATCC 13048 | - | >5.0 | | Enterococcus faecalis (VRE) ATCC 700802 | + | >5.3 | | Serratia marcescens ATCC 13880 | - | >4.5 | # Sterility A sterility validation for ChitoGauze™ was completed following ISO 11137:2006 requirements to demonstrate a 10° SAL using the VDmax 25 method. Changing the dimensional size of the dressing has no effect upon the sterility validation. #### 510(k) HemCon ChitoGauze Size & Model Num {6}------------------------------------------------ K092357 page 3/3 # Clinical Performance Data: No clinical data was required for evaluation of this device. # Conclusion: The modification to ChitoGauze to provide various dimensional sizes is neither a change to the intended use, nor an alteration of the fundamental scientific technology of the device. Special STO(Id) - Hem Con ChitoGauze Sizes & Model Numbers
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...