← Product Code [IYE](/productcode/IYE) · K092018

# OMNIPRO INCLINE (K092018)

_Iba Dosimetry GmbH · IYE · Sep 18, 2009 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K092018

## Device Facts

- **Applicant:** Iba Dosimetry GmbH
- **Product Code:** [IYE](/productcode/IYE.md)
- **Decision Date:** Sep 18, 2009
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.5050
- **Device Class:** Class 2
- **Review Panel:** Radiology

## Indications for Use

The OmniPro Incline is a QA beam measuring system intended to be used for the verification of dose distribution in radio therapy. The system is intended to measure proton, photon and electron beams.

## Device Story

OmniPro Incline is a radiation therapy QA tool for measuring and analyzing depth dose distributions of particle beams (up to 33 cm Water Equivalent Thickness). System includes a multi-layer ionization chamber array and an electrometer based on Tera chip technology. It measures single Bragg peaks and modulated distributions for both active and passive delivery systems. Features high spatial/temporal resolution (approx. 2mm WET; sampling down to 10ms). Software manages measurement and analysis, producing data compatible with IBA Dosimetry formats. Used by medical physicists/technicians in clinical radiotherapy environments to verify beam delivery accuracy, ensuring correct dose distribution for patient treatment.

## Clinical Evidence

No clinical data. Bench testing only.

## Technological Characteristics

System comprises multi-layer ionization chambers and a dedicated electrometer utilizing Tera chip technology. Measures proton, photon, and electron beams up to 33 cm WET. Spatial resolution ~2mm WET; temporal sampling down to 10ms. Software-based analysis tool for dose distribution verification. Compatible with IBA Dosimetry data formats.

## Regulatory Identification

A medical charged-particle radiation therapy system is a device that produces by acceleration high energy charged particles (e.g., electrons and protons) intended for use in radiation therapy. This generic type of device may include signal analysis and display equipment, patient and equipment supports, treatment planning computer programs, component parts, and accessories.

## Predicate Devices

- Omni-Pro Accept ([K011763](/device/K011763.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K092018

# 5 510(k) Summary

## 5.1 510(k) owner

IBA Dosimetry GmbH Bahnhofstrasse 5 90592 Schwarzenbruck Germany

Tel: +49 9128 607 0 Fax: +49 9128 607 10

#### 5.2 Contact Person

Martin Arold

#### 5.3 Preparation date

2009-06-09

#### 5.4 Trade Name

OminPro Incline

#### 5.5 Common name

Radiation therapy dose calculation QA tool.

#### 5.6 Classification Name

Accelerator, linear, medical

### 5.7 Predicate Devices

Omni-Pro Accept: K011763

### 5.8 Device Description

The Omni-Pro-Incline software is a workspace tool managing both the measurements and the analysis of depth dose distributions of particles with a range up to 33 cm Water Equivalent Thickness (WET): The software is delivered with a dedicated system of multi layer of ionization chambers and with a decicated electrometer based on the Tera chip technology. Single Bragg peaks as well as modulated distributions can be measured and analyzed with high spatial and temporal resolution (in the order of 2mm WET) with typical sampling time down to 10ms. The data format will be directly compatible with the one of the IBA Dosimetry conventional formats and at least easily exchangeable. The system is suitable for both active and passive delivery

SEP 1 8 2009

{1}------------------------------------------------

Image /page/1/Picture/0 description: The image shows the seal of the Department of Health & Human Services - USA. The seal features the department's name encircling a symbol. The symbol consists of a stylized caduceus, with three lines representing the serpent and staff, above a wavy line.

#### DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002

#### SEP & 8 2009

IBA Dosimetry GmbH % Mr. Chuck Lindley President IBA Dosimetry America 3150 Stage Post Dr., Suite 110 BARTLETT TN 38133

Re: K092018

Trade/Device Name: OmniPro Incline Regulation Number: 21 CFR 892.5050 Regulation Name: Medical charged-particle radiation therapy system Regulatory Class: II Product Code: IYE Dated: July 6, 2009 Received: July 6, 2009

#### Dear Mr. Lindley:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical

{2}------------------------------------------------

Page 2 -

device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to

http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address

http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Janine M. Morris Acting Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

### 4 Indications for Use Statement

510(k) Number (if known): -

Device Name: OmniPro Incline

Indications for Use:

The OmniPro Incline is a QA beam measuring system intended to be used for the verification of dose distribution in radio therapy. The system is intended to measure proton, photon and electron beams.

Prescription Use (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Herle Lume

(Division Sign-Off) Division of Reproductive, Abdominal, and Radiological Devices 510(k) Number

---

**Source:** [https://fda-staging.innolitics.com/device/K092018](https://fda-staging.innolitics.com/device/K092018)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
