BISQUE ZIRCONIA BLANKS, MODEL R610191, R610210, R610211, R610205
Applicant
Refractron Technologies Corp.
Product Code
EIH · Dental
Decision Date
Sep 10, 2009
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.6660
Device Class
Class 2
Indications for Use
Refractron Technologies Corporation Bisque Zirconia Blanks (Type BYZ), are indicated for use as a substructure for ceramic dental restorations. Prescription Use Only: All blanks are sold by or on the order of a dental professional. They are not for use by the general public or over the counter (OTC).
Device Story
High-purity, bisque-fired zirconia machining blanks; used as dental ceramic substructures. Dental lab technicians process blanks via CAD/CAM machining or copying techniques; metal chuck glued to blank for machine mounting. Porous blanks require post-machining sintering to achieve full density/strength; dense blanks require no heat treatment. Final restorations used by dentists for patient-specific dental appliances. Device provides material for custom dental restorations; benefits include precise machining of intricate shapes for patient-specific dental needs.
Clinical Evidence
No clinical data. Bench testing only.
Technological Characteristics
High-purity zirconia powder; bisque-fired machining blanks. Available in porous or dense forms. Dimensions vary (rectangular, disk, square). Processing via CAD/CAM or copying. Sintering required for porous variants. No software or electronic components.
Indications for Use
Indicated for use as a substructure for ceramic dental restorations in patients requiring dental appliances. Prescription use only.
Regulatory Classification
Identification
Porcelain powder for clinical use is a device consisting of a mixture of kaolin, felspar, quartz, or other substances intended for use in the production of artificial teeth in fixed or removable dentures, of jacket crowns, facings, and veneers. The device is used in prosthetic dentistry by heating the powder mixture to a high temperature in an oven to produce a hard prosthesis with a glass-like finish.
Predicate Devices
Zircar Zirconia, Inc. Bisque Zirconia Blanks (K081850)
Submission Summary (Full Text)
{0}------------------------------------------------
SEP 1 0 2009
K09/852
,
Refractron Technology Corporation (Pre-market Notification)
Page 14
# Appendix A (Summary of Safety And Effectiveness)
#### Submitter:
John Gagliardi, President (contact person) and official correspondent for RTC) MidWest Process Innovation, LLC 7736 Woodside Court Maineville, OH 45039 513-573-0085 (Telephone and fax) or 513-573-0519 (Telephone and fax) JGAGL777@One.Net
Trade Name: Refractron Technologies Corporation Bisque Zirconia Blanks
Common Name: Refractron Technology Corporation Bisque Zirconia Blanks
Classification Name: Porcelain Powder for Clinical Use
#### Summary of Safety and Effectiveness:
The Refractron Bisque Zirconia Blank is substantially equivalent in function and intended use to the Zircar Zirconia, Inc. Bisque Zirconia Blanks - K081850. This predicate device is presently on the market.
By definition, a device is substantially equivalent to a predicate device when the device has the same intended use and the same technological characteristics as the previously cleared predicate device. As such, it has been shown in this pre-market notification submission, that the differences between the Refractron Porcelain Powder Blanks and the Zirconia Blanks do not raise any questions regarding their safety and effectiveness. They are, as explained below, the same product
The Refractron Porcelain Powder Blanks, as designed and manufactured, are as exactly safe and effective as the predicate device and therefore are determined to be substantially equivalent to the referred predicate device. They are in fact, one-in-the same.
Note: Zircar Zirconia Blanks (the predicate device designated for this Pre-Market Notification submitted by Refractron Technologies Corporation, Newark, NY are actually, on a day-to-day basis, produced for Zircar Zirconia, Inc., PO Box 287, Florida, NY 10921-0287, i.e. the actual Bisque Zirconia Blanks so mentioned in K081850 are a product manufactured by Refractron Technologies Corporation for Zircania, Inc. Zircar Zirconia, Inc. has only one supplier for these blanks. i.e. Refractron Technologies Corporation.
Refractron Porcelain Powder Blanks are high purity, bisque fired zirconia machining blanks. The powders pressed to form these blanks are of a uniform size and well dispersed, ensuring no agglomerates. The resultant fine-grained, bisque body allows intricate shapes to be machined with specified tolerances. Refractron Technologies Corporation Blanks (exactly Zircar Zirconia, Inc. Blanks) are dental ceramic blanks designed for the manufacturing of substructures for ceramic dental appliances. The dental appliance is machined either by CAD/CAM machining or using the copying technique. Products are either porous or dense. Porous blanks can then be sintered to full density and strength. Dense blanks do not need a final heat treatment and are therefore ready for veneering immediately after machining. All appliances are for the sole use of the particular patient only. At the dental lab (Refractron's customer that processes the blanks) a metal chuck is glued on the end of the blank that holds it in the CAD/CAM machine which is used to machine the final dental restoration. At the completion of the machining steps, the dental restoration is fired, i.e. sintered, in the oven to harden the ZrQ2.
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows a circular seal with text around the perimeter and a symbol in the center. The text around the perimeter reads "HEALTH & HUMAN SERVICES USA". The symbol in the center is a stylized eagle with three lines representing its wings.
SEP 1 0 2009
Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center - WO66-G609 Silver Spring, MD 20993-0002
Refractron Technologies, Incorporated C/O Mr. John Gagliardi President MidWest Process Innovation, L.L.C. 7736 Woodside Court Maineville, Ohio 45039
Re: K091852
> Trade/Device Name: Bisque Zirconia Blanks RG10191, RG10210, RG10211, and RG10205
Regulation Number: 21 CFR 872.6660 Regulation Name: Porcelain Powder for Clinical Use Regulatory Class: II Product Code: EIH Dated: June 19, 2009 Received: June 23, 2009
Dear Mr. Gagliardi:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III. (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
## Page 2 - Mr. Gagliardi
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please contact the CDRH/Office of Surveillance and Biometrics/Division of Postmarket Surveillance at 240-276-3464. For more information regarding the reporting of adverse events, please go to http://www.fda.gov/cdrh/mdr/.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours
Susan Tanner
Susan Runner, D.D.S., M.A. Acting Division Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Refractron Technologies Corporation Pre-market Notification
Page 5
1071
### INDICATIONS FOR USE
510(k) Number (if known): Not known at this time.
Classification Name: Porcelain Powder For Clinical Use
Device Name: Refractron Technologies Corporation Bisque Zirconia Blanks
Indications for Use: Refractron Technologies Corporation Bisque Zirconia Blanks (Type BYZ), are indicated for use as a substructure for ceramic dental restorations.
Sizes: Various sizes and shapes, e.g. rectangular, disk-shaped, square, etc. and similar to the sizes mentioned in K081850
Prescription Use Only: All blanks are sold by or on the order of a dental X professional. They are not for use by the general public or over the counter (OTC).
Per Part 21 CFR 801, Subpart D
(Please Do Not write below this line-continue on another page as needed)
Concurrence of CDRH, Office of Device Evaluation (ODE)
of Page
(Division Sign-off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices
**510(k) Number:** K091852
K091852 Susan Fox
(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: K
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.