← Product Code [EZL](/productcode/EZL) · K091699

# AMSURE HYDROPHILIC LATEX FOLEY CATHETER (K091699)

_Amsino International, Inc. · EZL · Aug 10, 2009 · Gastroenterology, Urology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K091699

## Device Facts

- **Applicant:** Amsino International, Inc.
- **Product Code:** [EZL](/productcode/EZL.md)
- **Decision Date:** Aug 10, 2009
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 876.5130
- **Device Class:** Class 2
- **Review Panel:** Gastroenterology, Urology
- **Attributes:** Therapeutic, Pediatric

## Indications for Use

The AMSURE® HYDROPHILIC LATEX FOLEY CATHETER, is intended for use in the drainage of fluids from, and to the urinary tract/bladder.

## Device Story

AMSURE Hydrophilic Latex Foley Catheter is a retention-type urological catheter; dual-lumen drainage tube with two opposing distal drainage eyes; one lumen for fluid drainage, one for balloon inflation/deflation. Features connecting funnel and luer-activated valve. Constructed from silicone-coated natural latex with a lubricious/hydrophilic coating to facilitate insertion. Available in various French sizes (12Fr-28Fr) and balloon capacities (5cc, 30cc). Device is disposable, sterile (Ethylene Oxide), and intended for single use. Used in clinical settings for urinary tract/bladder fluid management. Healthcare providers insert the catheter to facilitate drainage; output is the physical removal or delivery of fluids to/from the bladder. Benefits include ease of insertion due to hydrophilic coating and effective fluid management.

## Clinical Evidence

Bench testing only. Biocompatibility requirements met. Verification and validation activities performed per 21 CFR 820.30; results demonstrated that predetermined criteria were met.

## Technological Characteristics

Dual-lumen retention catheter; silicone-coated natural latex; lubricious/hydrophilic coating; French sizes 12Fr-28Fr; balloon capacities 5cc and 30cc; Ethylene Oxide sterilization.

## Regulatory Identification

A urological catheter and accessories is a flexible tubular device that is inserted through the urethra and used to pass fluids to or from the urinary tract. This generic type of device includes radiopaque urological catheters, ureteral catheters, urethral catheters, coudé catheters, balloon retention type catheters, straight catheters, upper urinary tract catheters, double lumen female urethrographic catheters, disposable ureteral catheters, male urethrographic catheters, and urological catheter accessories including ureteral catheter stylets, ureteral catheter adapters, ureteral catheter holders, ureteral catheter stylets, ureteral catheterization trays, and the gastro-urological irrigation tray (for urological use).

## Predicate Devices

- AMSURE FOLEY CATHETER (k030120)
- BARDEX I.C. Latex Foley Catheter (k040658)
- BARDEX LUBRI-Sil All Silicon Lubricious Coated Foley Catheters (k070508)
- BARDEX LUBRI-Sil Foley Catheters (k984084)

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

510k SUMMARY

K091699

Page 1 of 4

This summary of safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92

Submitter and Contact Person:

AMSINO International, Inc AUG 1 0 2009 855 Towne Center Drive Pomona, CA 91767 Jesus T. Farinas Manager, Quality Assurance & Regulatory Affairs

Establishment Number

2085175

Name of the Device: Classification Name:

Proprietary Name:

Urological Catheter/Catheter, Retention Type, Balloon AMSURE® HYDROPHILIC LATEX FOLEY CATHETER

510k Number Regulation Number: 876.5130 Class: ll Classification Product Code: 78 EZL

Predicate Devices: AMSURE FOLEY CATHETER (k030120) BARDEX I.C. Latex Foley Catheter (k040658) BARDEX LUBRI-Sil All Silicon Lubricious Coated Foley Catheters (k070508) BARDEX LUBRI-Sil Foley Catheters (k984084)

Intended use of the Device:

The AMSURE "HYDROPHILIC LATEX FOLEY CATHETER, is intended for use in the drainage of fluids from, and to the urinary tract/bladder.

{1}------------------------------------------------

## Device Description:

The AMSURE Hydrophilic Latex Foley Catheter is a retention type urological catheter made of silicone coated natural Latex material modified with the addition of a lubricious/hydrophilic coating to facilitate the insertion of the catheter. It consists of a double lumen drainage tube with 2 opposing drainage eyes at the distal end. One lumen drains fluid to and from the urinary tract, while the second lumen is for inflation and deflation of the balloon. On the opposing end of the shaft are a connecting funnel and a luer activated valve. This product is available in a combination of French sizes, balloon capacities and lengths to accommodate pediatric and adult male and female applications. The device will be offered in French sizes from 12Fr to 28Fr, balloon size of 5 cc and 16-28 Fr in balloon size of 30cc. The device is disposable, sterile (Ethylene Oxide sterilization) and for single use only. The coating has been tested for its safety and efficacy.

## Fundamental Scientific Technology:

The catheter described in this premarket notification have similar technological features and performance as the predicate device(s). The catheters are manufactured from silicone coated natural latex material and have lubricious, hydrophilic coating that facilitates insertion of the catheter. The device under submission having the same material, manufactured in the same manner and having a lubricious coat function have the same intended use as currently marketed devices raise no new issues of safety and effectiveness and are substantially equivalent.

10

{2}------------------------------------------------

K091699
Pg. 3 of 4

# comparison table of the features of the Subject device to the PREDICATE DEVICE(S)

|                      | Device on<br>submission                                | Predicate device<br>k030120                    | Bardex<br>k040658                                                      | Bardex<br>K070508                              | Bardex<br>k984084                              |
|----------------------|--------------------------------------------------------|------------------------------------------------|------------------------------------------------------------------------|------------------------------------------------|------------------------------------------------|
| Material             | Latex                                                  | Latex                                          | Latex                                                                  | Silicon                                        | Silicon                                        |
| Lumen                | Dual                                                   | Dual                                           | Dual                                                                   | Dual                                           | Dual                                           |
| Lubricious<br>coated | Yes                                                    | No                                             | Yes                                                                    | Yes                                            | Yes                                            |
| Sterile              | Yes-EtO                                                | Yes Gamma                                      | Yes EtO                                                                | Yes EtO                                        | Yes EtO                                        |
| Biocompa<br>tibility | Meet<br>Requirements                                   | Meet<br>Requirements                           | Meet<br>Requirements                                                   | Meet<br>Requirements                           | Meet<br>Requirements                           |
| Intended<br>Use      | Drainage of fluids<br>to/from urinary<br>tract/bladder | Drainage of<br>fluids to/from<br>urinary tract | Drainage<br>and/or<br>collection<br>and/or<br>measurement<br>of urine. | Drainage of<br>fluids to/from<br>urinary tract | Drainage of<br>fluids to/from<br>urinary tract |

{3}------------------------------------------------

K091699
Page 4 of 4

#### DECLARATION OF CONFORMITY

(Special 510k: AMSURE® Hydrophilic Latex Foley Catheter)

I certify as the Vice President for Quality Assurance and Regulatory Affairs of Amsino International, that as required by the risk analysis, all verification and validation activities were performed by the designated individual(s) and the results demonstrate that the predetermined criteria were met. In addition, we certify that the manufacturing facility is in conformance with the design control procedure requirements as specified in 21 CFR 820.30 and the records are available for review.

Gang Chen, VP Quality Assurance and Regulatory Affairs

(Signature) the text in the image is

{4}------------------------------------------------

## DEPARTMENT OF HEALTH & HUMAN SERVICES

Public Health Service

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002

Mr. Jesus Farinas Quality Assurance and Regulatory Affairs Manager Amsino International, Inc. 855 Towne Center Drive POMONA CA 91767

AUG 1 0 2009

Re: K091699

Trade/Device Name: AMSURE® HYDROPHILIC LATEX FOLEY CATHETER Regulation Number: 21 CFR 876.5130 Regulation Name: Urological catheter and accessories Regulatory Class: II Product Code: EZL Dated: July 20, 2009 Received: July 28, 2009

Dear Mr. Farinas:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical

{5}------------------------------------------------

device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/cdrh/mdr/ for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Judy M. Morris

Janine M. Morris Acting Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{6}------------------------------------------------

# INDICATIONS FOR USE

510(k) Number (if known): k091699

RD51033

DEVICE NAME:

INDICATIONS FOR USE:

The AMSURE® HYDROPHILIC LATEX FOLEY CATHETER, is intended for use in the drainage of fluids from, and to the urinary tract/bladder.

Prescription Use X (Part 21 CFR801 Subpart D) AND/OR

Over-the Counter Use (21 CFR 801 Subpart C)

PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED

Concurrence of CDRH, Office of Device Evaluation (ODE)

Signature

Division Sign-Off Division of Reproductive, Abdominal, and Radiological Device 510(k) Number

Page 1 of

---

**Source:** [https://fda-staging.innolitics.com/device/K091699](https://fda-staging.innolitics.com/device/K091699)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
