SPIDER SURGICAL INSTRUMENTS, MODELS 90004, 90005, 90007, 90009, 90010, 90012, 90013, 90015

K091697 · Transenterix, Inc. · GCJ · Sep 28, 2009 · Gastroenterology, Urology

Device Facts

Record IDK091697
Device NameSPIDER SURGICAL INSTRUMENTS, MODELS 90004, 90005, 90007, 90009, 90010, 90012, 90013, 90015
ApplicantTransenterix, Inc.
Product CodeGCJ · Gastroenterology, Urology
Decision DateSep 28, 2009
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1500
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The SPIDER™ Surgical Instruments are intended for use in minimally invasive surgical procedures for grasping, mobilizing, dissecting, retracting, cutting, cauterizing, ligating, suction/irrigation and other manipulation of tissues and vessels during a laparoscopic procedure under direct and/or endoscopic visualization.

Device Story

SPIDER™ Surgical Instruments are a set of rigid and flexible laparoscopic tools designed for use with the SPIDER™ Single Port Device or other laparoscopic access systems. The set includes graspers, dissecting forceps, scissors, clip appliers, suction/irrigation probes, and monopolar electrocautery instruments. Rigid instruments are reusable and require autoclaving; flexible instruments are single-use and ethylene oxide sterilized. Operated by surgeons in an OR setting, these instruments are advanced through cannulas to the surgical site to perform standard laparoscopic tasks. The devices provide mechanical or electrosurgical tissue manipulation under direct or endoscopic visualization. They function similarly to conventional laparoscopic instruments, allowing surgeons to perform standard surgical maneuvers. Benefits include facilitating access and manipulation within the surgical space during minimally invasive procedures.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Manual laparoscopic surgical instruments. Materials include standard medical-grade components suitable for abdominal surgery. Designed for single-port access with extended reach capabilities. Sterilization via standard methods for reusable surgical instruments. No software or electronic components.

Indications for Use

Indicated for use in minimally invasive laparoscopic surgical procedures for tissue and vessel manipulation, including grasping, mobilizing, dissecting, retracting, cutting, cauterizing, ligating, and suction/irrigation.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls: 1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following: 1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures. 2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use. 3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use. 2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes. 3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches 4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error. 5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program. (6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms. (7) Labeling must include: (i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified; (ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA; (iii) Identification of compatible devices; (iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification; (v) Reprocessing instructions for reusable components; (vi) A shelf life for any sterile components; (vii) A description of the device-specific use training program; (viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and (ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance. (8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include: (i) Device motion accuracy and repeatability; (ii) System testing; (iii) Instrument reliability; (iv) Crosstalk; (v) Table motion control; (vi) Thermal effects on tissue; (vii) User-device interface performance; (viii) Workspace access testing; and (ix) Performance testing with compatible devices. (9) Software verification, validation, and hazard analysis must be performed. (10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed. (11) Performance data must demonstrate the sterility of all patient-contacting device components. (12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life. (13) Performance data must validate the reprocessing instructions for the reusable components of the device. (14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible. (15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic. (16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information: (i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and (ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.

Submission Summary (Full Text)

{0} DJA #00292 # 510(k) Summary This summary of safety and effectiveness information is being submitted in accordance with requirements of 21 CFR Part 807.92. Date: June 8, 2009 ## 1. Submitter: Submitted by: TransEnterix, Inc. 3908 Patriot Drive, Suite 170 Durham, NC 27703 TEL: 919-541-9977 FAX: 919-541-9978 Contact: Tammy Carrea Director, Regulatory Affairs and Quality Assurance ## 2. Device: Propriety Name: SPIDER™ Surgical Instruments Common Name: Laparoscopic instrument and accessory Classification Name: Endoscope and accessories Classification: Class II 21 CFR 876.1500 Product Code: GCJ ## 3. Predicate Device: Snowden-Pencer Reusable Laparoscopic Instruments Olympus: FG Series Grasping Forceps and Surgical Scissors Novare: RealHand High Dexterity Instruments Weck: Hem-O-Lok™ Ligating Clip Applier US Surgical Autosuture™ Endo Clip III Clip Applier Cabot Medical: Surgiflex Wave Suction Irrigation Probe ## 4. Description: The SPIDER™ Surgical Instruments are surgical instruments to facilitate laparoscopic surgery. They are intended for use with the SPIDER™ Single Port Device or other laparoscopic access device that facilitates the use of rigid and/or flexible instrumentation. The surgical instruments may be categorized as follows: - Rigid instruments - Flexible instruments - Flexible Electrocautery or energy instruments ### 1. Rigid Surgical Instruments Page 1 of 3 {1} Page 2 of 3 The rigid instrument set includes a rigid grasper for grasping, mobilizing, or retracting tissue. It is a re-usable device that is provided to the user non-sterile with instructions for cleaning and autoclaving. ## 2. Flexible Instruments The flexible instruments are pre-sterilized, single use disposable devices. The devices are ethylene oxide sterilized. The flexible instrument set includes: - Flexible grasping forceps for grasping, mobilizing, or retracting tissue - Flexible dissecting forceps for dissecting tissue - Flexible scissors for cutting tissue - Flexible 5mm clip applicer for ligation - Flexible suction/irrigation probe to deliver sterile irrigation fluids and evacuate blood, tissue debris, and smoke from the surgical site ## 3. Flexible Electrocautery Instruments The flexible electrocautery instruments are pre-sterilized, single use disposable devices. The devices are ethylene oxide sterilized. The electrocautery instrument set includes: - Flexible monopolar electrocautery instruments for cutting and coagulation of tissue ## 5. Indications for Use: The SPIDER™ Surgical Instruments are intended for use in minimally invasive surgical procedures for grasping, mobilizing, dissecting, retracting, cutting, cauterizing, ligating, suction/irrigation and other manipulation of tissues and vessels during a laparoscopic procedure under direct and/or endoscopic visualization. ## 6. Comparison of Technological Characteristics with Predicate: The SPIDER™ Surgical Instruments have the same intended use and function of other currently marketed laparoscopic and endoscopic surgical instruments. Like the predicates the instruments have the same end effecter/jaw/tip designs. The devices achieve the same function using the same modes of action. The rigid and flexible instruments are passed through the TransEnterix cannulas (IDTs) and advanced to the surgical site, exactly in the same manner as other surgical devices are passed through conventional trocars/cannulas used in standard single port or multi-port laparoscopic surgery. The SPIDER™ Flexible Instruments utilize the same or similar design, dimensions, materials of construction, and sterilization as that of the predicates. Similar to the predicate devices the SPIDER™ Flexible Instruments are provided pre-sterilized, are disposable, and are single use devices, the same as other predicate devices. Similar to the predicate devices the SPIDER™ Rigid Grasper is provided non-sterilize and is cleaned and autoclaved between uses the same as the predicate device. {2} DJA 200294 The flexible design and length of the SPIDER™ Flexible Instruments are essentially the same as other predicate devices currently marketed. The design of the devices, in terms of length and flexibility, allows both groups of devices to achieve access to the surgical space through a trocar and perform their intended functions in a similar manner. The slight difference in shaft length does not present any new issues of safety or efficacy. Any technological differences between the SPIDER™ Surgical Instruments and the predicates have been mitigated via testing. Thus the SPIDER™ Surgical Instruments do not introduce any new issues of safety or effectiveness compared to other similar laparoscopic or endoscopic surgical devices currently marketed. ## 7. Performance Data: The SPIDER™ Surgical Instruments have been functionally tested in bench top simulation studies and found to perform their intended functions for laparoscopic surgical procedures. The SPIDER™ Flexible Instruments have been tested for sterility using ethylene oxide to demonstrate the ability to sterilize and produce a sterility assurance level of 1×10⁻⁶. The SPIDER™ Rigid Grasper has been tested for cleaning and autoclave sterilization to assure safety of multiple uses. The SPIDER™ Instruments have been tested for biocompatibility in accordance with ISO 10993-1 based on type and duration of contact to assure that they are non-cytoxic, non-sensitizing and non-irritating. The SPIDER™ Electrocautery Instruments have been tested for compliance to IEC 60601-2-2 and found to be capable of operation up to a maximum voltage of 3500 Volts peak. The SPIDER™ Surgical Instruments have been tested in a pre-clinical swine study to compare their performance to that of standard laparoscopic instruments and to assure their performance and success in laparoscopic procedures. When compared to the predicate devices, the SPIDER™ Surgical Instruments do not incorporate any significant technological differences that affect safety and efficacy, therefore, clinical data was not deemed necessary for evaluation of substantial equivalence. These verification and validation test results are sufficient to demonstrate safety and effectiveness compared to predicate devices used in standard laparoscopic surgical techniques. Any minor technological differences in the design or materials of the SPIDER™ Surgical Instruments have been evaluated and found to present no new issues of safety and effectiveness. ## 8. Conclusion: The conclusion drawn from the test data is that the SPIDER™ Surgical Instruments are as safe and effective as the predicate devices, perform similarly to other legally marketed predicate devices for laparoscopic surgery, and do not raise any new issues of safety or effectiveness. Page 3 of 3
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...