REAL-TIME PCR INTERNAL CONTROL 2B SET

K083430 · Nanogen, Inc. · OLD · Jan 15, 2009 · Clinical Chemistry

Device Facts

Record IDK083430
Device NameREAL-TIME PCR INTERNAL CONTROL 2B SET
ApplicantNanogen, Inc.
Product CodeOLD · Clinical Chemistry
Decision DateJan 15, 2009
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1660
Device ClassClass 1

Indications for Use

The Real-Time PCR Internal Control 2B Set consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control 2B Set can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes.

Device Story

Real-Time PCR Internal Control 2B Set provides reagents for monitoring extraction and amplification processes in real-time PCR assays. Components include IC2 Template (nonsense DNA fragment in pUC19 plasmid vector), IC2-B Primers, and IC2-B Probe (fluorescently labeled). Used in laboratory settings; operators are laboratory personnel. The control is added to the PCR process to detect systemic variation. If the control fails to amplify or detect as expected, it indicates potential issues with the extraction or amplification steps of the assay. Benefits include quality assurance for PCR-based diagnostic workflows.

Clinical Evidence

No clinical data; bench testing only.

Technological Characteristics

Reagents in 1X TE buffer. IC2 Template: DNA fragment in pUC19 plasmid. IC2-B Probe: MGB moiety, fluorescent dye (523 nm excitation/554 nm emission), and quencher. Intended for real-time PCR amplification. Unassayed control material.

Indications for Use

Indicated for use as an unassayed internal extraction and amplification process control in any real-time PCR assay to detect systemic variation during the extraction and amplification process.

Regulatory Classification

Identification

A quality control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (assayed and unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (assayed and unassayed) for blood gases, electrolytes, enzymes, multianalytes (all kinds), single (specified) analytes, or urinalysis controls.

Submission Summary (Full Text)

{0} 1 # 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: K083430 B. Purpose for Submission: Nanogen's Real-Time PCR internal control material falls under CFR 862.1660 Quality Control Material (assayed and unassayed) and is Class I exempt. However, since it operates using a different fundamental scientific technology than a legally marketed device, it trips the limitations of exemptions in CFR 862.9b and requires premarket notification. C. Measurand: Internal control template D. Type of Test: PCR E. Applicant: Nanogen, Inc. F. Proprietary and Established Names: Real-Time PCR Internal Control 2B Set G. Regulatory Information: 1. Regulation section: 21CFR 862.1660 Quality Control Material (assayed and unassayed) 2. Classification: Class I exempt 3. Product code: OLD-Internal control, not assay specific 4. Panel: {1} (75) Clinical Chemistry ## H. Intended Use: 1. Intended use(s): The Real-Time PCR Internal Control 2B Set consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control 2B Set can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor other real-time PCR processes. 2. Indication(s) for use: Same as intended use 3. Special conditions for use statement(s): In Vitro diagnostic use only 4. Special instrument requirements: NA ## I. Device Description: The Real-Time PCR Internal Control 2B Set contains the IC2 Template, the IC2-B Primers, and the IC2-B Probe. The IC2-B Primers and Probe are optional, and can be used to amplify and detect the IC2 Template. Alternatively, other primers and probe may be used if targeted toward the IC2 Template. Laboratories should dilute the IC2 Template as well as primers and probe that are to be used for the amplification and determine empirically the optimal concentrations of all control reagents for your assay. The IC2 Template consists of a nonsense, non-specific target DNA fragment cloned into the plasmid vector pUC19 in a 1X TE buffer solution. The target DNA fragment of the IC2 Template is as follows: 5' - CTGCACGGACCAGTTACTTTACGGACCACGTACCGCATTGGTACAAGA TCTCCGGTAGAAAAAATGAG - 3' The IC2-B Primers consists of two primers in a 1X TE buffer solution. The sequences of the primers are as follows: {2} 3 5' – CTGCACGGACCAGTTACTTTACG – 3' 5' – CTCATTTTTTCTACCGGAGATCTTGT – 3' The IC2-B Probe consists of one probe in a 1X TE buffer solution. The IC2-B Probe is labeled with a proprietary dye and has an excitation wavelength maxima of 523 nm and an emission wavelength maxima of 554 nm. The sequence of the probe is as follows: 5' – MGB Moiety – Fluorescent Dye – AATGCGCTACGTGGTCC – Quencher – 3' J. Substantial Equivalence Information: 1. Predicate device name(s): VITROS Chemistry Products HCY Performance Verifiers I, II & III 2. Predicate K number(s): K061588 3. Comparison with predicate: | Similarities | | | | --- | --- | --- | | Item | Device | Predicate | | Type of Material | Quality control material | Quality control material | | Purpose | Monitors performance and process | Monitors performance and process | | Differences | | | | --- | --- | --- | | Item | Device | Predicate | | Intended Use | The Real-Time PCR Internal Control 2B Set consists of reagents intended for use as an unassayed internal extraction and amplification process control in any real-time polymerase chain reaction (PCR) assay. The Internal Control 2B Set can be used to detect systemic variation that may arise during the extraction and amplification process associated with real-time PCR assays. The set is not intended to monitor | CITROS Chemistry Products HCY Performance Verifiers are assayed controls used to monitor performance of VITROS HCY Reagents on VITROS 5,1 Chemistry Systems | {3} | Differences | | | | --- | --- | --- | | Item | Device | Predicate | | | other real-time PCR processes. | | | Product Type | Unassayed control | Assayed control | | Assay Method | Real-time PCR | Homogeneous Enzymatic | | Matrix | DNA fragment cloned into a plasmid vector in a buffer solution | Prepared human serum with preservatives added | K. Standard/Guidance Document Referenced (if applicable): Guidance for Industry and FDA Staff Assayed and Unassayed Quality Control Material, http://www.fda.gov/cdrh/oivd/guidance/2231.pdf. L. Test Principle: NA M. Performance Characteristics (if/when applicable): 1. Analytical performance: a. Precision/Reproducibility: NA b. Linearity/assay reportable range: NA c. Traceability, Stability, Expected values (controls, calibrators, or methods): Provided stability studies to justify expiration dating. d. Detection limit: NA e. Analytical specificity: NA f. Assay cut-off: NA {4} 2. Comparison studies: a. Method comparison with predicate device: NA b. Matrix comparison: NA 3. Clinical studies: a. Clinical Sensitivity: NA b. Clinical specificity: NA c. Other clinical supportive data (when a. and b. are not applicable): NA 4. Clinical cut-off: NA 5. Expected values/Reference range: NA N. Proposed Labeling: The labeling is sufficient and it satisfies the requirements of 21 CFR Part 809.10. O. Conclusion: 1. The submitted information in this premarket notification is complete and supports a substantial equivalence decision. 5
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...