BONART ART-L5 LED CORDLESS CURING LIGHT

K082971 · Bonart Co., Ltd. · EBZ · Nov 13, 2008 · Dental

Device Facts

Record IDK082971
Device NameBONART ART-L5 LED CORDLESS CURING LIGHT
ApplicantBonart Co., Ltd.
Product CodeEBZ · Dental
Decision DateNov 13, 2008
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.6070
Device ClassClass 2
AttributesTherapeutic

Indications for Use

ART-L5 LED Cordless Curing Light System is used in light polymerization of dental composite and curing dental restorative thru source of illuminations.

Device Story

The Bonart ART-L5 is a cordless LED curing light used by dental professionals to polymerize light-cured dental restorative materials. The device utilizes an LED light source to emit specific wavelengths required for curing composites. It is a handheld, battery-operated unit designed for use in dental clinics. By providing a portable source of illumination, it allows clinicians to harden dental resins during restorative procedures, facilitating efficient dental treatments.

Clinical Evidence

Bench testing only.

Technological Characteristics

Handheld cordless form factor; LED light source for polymerization; battery-powered; intended for dental restorative applications; Class II device (Product Code EBZ).

Indications for Use

Indicated for light polymerization of dental composite and curing of dental restorative materials in a clinical dental setting.

Regulatory Classification

Identification

An ultraviolet activator for polymerization is a device that produces ultraviolet radiation intended to polymerize (set) resinous dental pit and fissure sealants or restorative materials by transmission of light through a rod.

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal features a stylized eagle with its wings spread, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. The eagle is depicted in black, and the text is also in black against a white background. The overall design is simple and conveys a sense of official authority. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Bonart Company, Limited C/o Mr. Eric L. Ong Sales and Operations Manager Bonart Medical Technology, Incorporated 398 South Lemon Creek Drive, Suite L Walnut, California 91789 Re: K082971 Trade/Device Name: BONART ART-L5 LED CORDLESS CURING LIGITT Regulation Number: 872.6070 Regulation Name: Ultraviolet Activator for Polymerization Regulatory Class: II Product Code: EBZ Dated: October 2, 2008 Received: October 6, 2008 NOV 1 3 2008 Dear Mr. Ong: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the cnclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. lf your device is classified (sec above) into cither class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Snegite Y. Michael Daro. Chiu S. Lin, Ph. D Division Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health {2}------------------------------------------------ ## Indications for Use 510(k) Number (if known): To be assigned by FDA Device Name: Bonart- ART-L5 LED Cordless Curing Light System Indications For Use: ART-L5 LED Cordless Curing Light System is used in light polymerization of dental composite and curing dental restorative thru source of illuminations. Prescription Use 2 (Part21 CFR 801 SubpartD) AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Susan Runner ision of Anesthesiology, General Hospital, ction Control, Dental Devices 510(k) Number. K88297 Page 1 of Original 510(k) Submission Bonart Co., Ltd. FDA Reg. No.9710363 Device Name/Model: BONART ART-L5 LED CORDLESS CURING LIGHT 7
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...