COSMAN G4 RADIOFREQUENCY GENERATOR, MODEL RFG-4

K082051 · Cosman Medical, Inc. · GXD · Oct 16, 2008 · Neurology

Device Facts

Record IDK082051
Device NameCOSMAN G4 RADIOFREQUENCY GENERATOR, MODEL RFG-4
ApplicantCosman Medical, Inc.
Product CodeGXD · Neurology
Decision DateOct 16, 2008
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 882.4400
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Cosman G4 Radiofrequency Generator is indicated for use in procedures to create radiofrequency lesions for the treatment of pain, or for lesioning nerve tissue for functional neurosurgical procedures. The Cosman G4 Radiofrequency Generator is used with separately approved Cosman Radiofrequency Probes.

Device Story

Cosman G4 Radiofrequency Generator is an electrosurgical device used by clinicians to create thermal lesions in nerve tissue. It operates by delivering radiofrequency energy through separately approved Cosman Radiofrequency Probes. The device is intended for pain management and functional neurosurgery. It functions as a power source and control unit for the probes, allowing the physician to monitor and adjust energy delivery to achieve the desired therapeutic lesion. The output is used to modulate or destroy nerve tissue to alleviate pain or address neurological conditions. It is designed for clinical use in surgical or procedural settings.

Clinical Evidence

Bench testing only.

Technological Characteristics

Radiofrequency lesion generator; Class II device (21 CFR 882.4400); utilizes radiofrequency energy for tissue ablation; designed for use with compatible Cosman Radiofrequency Probes.

Indications for Use

Indicated for patients requiring radiofrequency lesioning for pain management or functional neurosurgical nerve tissue lesioning.

Regulatory Classification

Identification

A radiofrequency lesion generator is a device used to produce lesions in the nervous system or other tissue by the direct application of radiofrequency currents to selected sites.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ OCT 1 6 2008 K0 82051 Page 1 of ① ## 510(k) Summary | Device Name: | Cosman G4 Radiofrequency Generator | |---------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------| | Common Name: | G4 | | Manufacturer: | Cosman Medical, Inc.<br>76 Cambridge St., Burlington MA 01803. USA<br>Tel. 781-272-6561. Fax 781-272-6563 | | Contact Name: | Louis Falcone, Director of RA/QA<br>email: Ifalcone@cosmanmedical.com | | Establishment Registration No.: | 3004867882 | | Classification: | 882.4400, Radiofrequency Lesion Generator, Class II<br>Neurology Devices, Product Code: GXD | | Performance Standard: | No applicable performance standards have been issued<br>under section 514 or under section 513(b) of the Food,<br>Drug, and Cosmetic Act. | | Predicate Devices: | Cosman RF Lesion Generator, model RFG-1A<br>(FDA Substantial Equivalence, K050084) | | | NeuroTherm RF Pain Management Generator NT1000<br>(FDA Substantial Equivalence, K052878) | Statement of Intended Use: The Cosman G4 Radiofrequency Generator is indicated for use in procedures to create radiofrequency lesions for the treatment of pain, or for lesioning nerve tissue for functional neurosurgical procedures. The Cosman G4 Radiofrequency Generator is used with separately approved Cosman Radiofrequency Probes. Device Substantial Equivalence: The Cosman G4 Radiofrequency Generator has been compared to previously 510(k) cleared devices with respect to intended use and tachnological characteristics. Performance testing was done to validate the intended use of the Cosminon device. The comparison and performance test results in this 510(k) notification show that the Cosman G4 Radiofrequency Generator is substantially equivalent to the predicated devices and is safe and effective for the intended use. {1}------------------------------------------------ Image /page/1/Picture/13 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle or bird-like figure. The bird is facing to the right and has three stylized wing shapes. OCT 1 6 2008 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Cosman Medical, Inc. % Mr. Louis Falcone Director, RA/QA 76 Cambridge Street Burlington, Massachusetts 01803 Rc: K082051 Trade/Device Name: Cosman G4 Radiofrequency Generator Regulation Number: 21 CFR 882.4400 Regulation Name: Radiofrequency lesion generator. Regulatory Class: II Product Code: GXD Dated: September 08, 2008 Received: September 26, 2008 Dear Mr. Falconc: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {2}------------------------------------------------ Page 2 - Mr. Louis Falcone This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely vours. Mark N. Millerson Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ ## Indications for Use Statement 510(k) Number: (if Known) 0 82051 Device Name: Cosman G4 Radiofrequency Generator Indications for Use Statement: The Cosman G4 Radiofrequency Generator is indicated for use in procedures to create radiofrequency lesions for the treatment of pain, or for lesioning nerve tissue for functional neurosurgical procedures. The Cosman G4 Radiofrequency Generator is used with separately approved Cosman Radiofrequency Probes. Prescription Use X Over-The Counter Use (part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE, CONTINUE ON ANOTHER PAGE IF NEEDED) And/Or Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 Neil R. Oyler Forman (Division Sign-6 Division of General, Restorative, and Neurological Devices **510(k) Number** K082051
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...