← Product Code [HWC](/productcode/HWC) · K081510

# TIGER CANNULATED SCREW SYSTEM (K081510)

_Trilliant Surgical, Ltd. · HWC · Aug 4, 2008 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K081510

## Device Facts

- **Applicant:** Trilliant Surgical, Ltd.
- **Product Code:** [HWC](/productcode/HWC.md)
- **Decision Date:** Aug 4, 2008
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The Tiger Cannulated Screw Fixati on System implants (screws) are intended for fixation of fractures, non-unions, arthrodeses and osteotomies of the small bones In the hand and foot.

## Device Story

Tiger Cannulated Screw System consists of titanium alloy bone screws (2.0mm, 2.4mm, 3.0mm, 4.0mm diameters) and associated surgical instruments (drill bits, countersinks, drivers, depth gauge, screw remover, K-wires). Used by surgeons in clinical settings for bone fixation following trauma or osteotomy in the hand and foot. Facilitates bone stabilization; aids healing process.

## Clinical Evidence

No clinical data; bench testing only.

## Technological Characteristics

Titanium alloy (Ti-6Al-4V) per ASTM F136. Cannulated bone screw design. Diameters: 2.0mm, 2.4mm, 3.0mm, 4.0mm. Manual surgical instrumentation.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

## 510(k) Summary for the Tiger Cannulated Screw System

In accordance with 21 CFR 807.92 of the Federal Code of Regulations the following 510(k) summary is submitted for the Tiger Cannulated Screw System.

Date Prepared: May 27, 2008

AUG - 4 2008

| 1. Submitter:                                                 | Contact Person:                                                                                                 | A |
|---------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------|---|
| Trilliant Surgical Ltd<br>1630 W.13th St<br>Houston, TX 77008 | J.D. Webb<br>The OrthoMedix Group, Inc.<br>1001 Oakwood Blvd<br>Round Rock, TX 78681<br>Telephone: 512-388-0199 |   |

| 2. Trade name:       | Tiger Cannulated Screw System                                 |
|----------------------|---------------------------------------------------------------|
| Common Name:         | Bone screw                                                    |
| Classification Name: | Screw, Fixation, Bone<br>Class II per 21 CFR section 888.3040 |
|                      | HWC                                                           |

#### 3. Predicate or legally marketed devices which are substantially equivalent:

The Tiger Cannulated Screw System is substantially equivalent to similar previously cleared cannulated screws.

### 4. Description of the device:

The Tiger Cannulated Screw System is comprised of screws used for bone fixation of the hand and foot following trauma or osteotomy. The system features 2.0mm diameter, 2.4mm diameter, 3.0mm diameter and 4.0mm diameter cannulated screws. System instruments include 2.0mm/2.4mm drill bit, countersink, driver, 3.0mm/4.0mm drill bit, countersink, driver, screw driver handle, depth gauge, screw remover and K-wires to facilitate the placement of screws.

### Materials:

The screws will be manufactured from titanium alloy (Ti-6Al-4V) per ASTM F136.

### Function:

The Tiger Cannulated Screw Fixation System is comprised of screws used for bone fixation of the hand and foot following trauma or osteotomy.

### 5. Intended Use:

The Tiger Cannulated Screw Fixati on System implants (screws) are intended for fixation of fractures, non-unions, arthrodeses and osteotomies of the small bones In the hand and foot.

#### Comparison of the technological characteristics of the device to predicate and legally marketed 6. devices:

Due to the similarity of materials and design to both pre-enactment and post-enactment devices, Trilliant Surgical believes that the Tiger Cannulated Screw Fixation System does not raise any new safety or effectiveness issues and does not require any nonclinical testing.

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes forming its body and wing. The eagle faces to the right. Encircling the eagle is the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Trillian Surgical Ltd. % The OrthoMedix Group, Inc. Mr. J.D. Webb 1001 Oakwood Boulevard Round Rock, Texas 78681

AUG - 4 2008

Re: K081510

Trade/Device Name: Tiger Cannulated Screw Fixation System Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: II Product Code: HWC Dated: May 27, 2008 Received: May 29, 2008

Dear Mr. Webb:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{2}------------------------------------------------

Page 2 - Mr. J.D. Webb

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket, Surveillance at (240) 276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at (240) 276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at toll-free number (800) 638-2041 or (240) 276-3150 or the Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

Mark M. Millman

- Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure

{3}------------------------------------------------

# Indications for Use

510(k) Number (if known): _K0815 | را | ر

Device Name: _________________________________________________________________________________________________________________________________________________________________

Indications for Use:

The Tiger Cannulated Screw Fixation System implants (screws) are intended for fixation of fractures, non-unions, arthrodeses and osteotomies of the small bones In the hand and foot.

Prescription Use _ X (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use _ (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Mark A. Wilkerson

Division of General, Restorative, and Neurological Devices

0815 510(k) Number

---

**Source:** [https://fda-staging.innolitics.com/device/K081510](https://fda-staging.innolitics.com/device/K081510)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
