K081118 · Noras Mri Products GmbH · MOS · May 2, 2008 · Radiology
Device Facts
Record ID
K081118
Device Name
NORAS MR-BI320-PA 1.5T
Applicant
Noras Mri Products GmbH
Product Code
MOS · Radiology
Decision Date
May 2, 2008
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 892.1000
Device Class
Class 2
Attributes
3rd-Party Reviewed
Indications for Use
The intended use of the Noras MR-BI320-PA 1.5T is, in conjunction with a Magnetic Resonance Scanner, the MR examination of the female breast. It is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images of the internal structures of the female breast. When interpreted by a trained physician, these images provide information that can be useful in determining diagnosis. The included Breast Biopsy Unit Bl160-2 permits MR guided breast biopsy, wire localization of lesions that can be performed by a trained physician.
Device Story
Patient rest system with integrated immobilization/biopsy unit and 4-channel phased array receive-only coil; used in conjunction with 1.5T MRI scanners. Patient lies in prone position on coil/rest; coil captures MR signals from breast tissue. Biopsy unit allows physician-guided needle placement or wire localization of lesions under MR control. Output consists of MR images interpreted by physicians to aid diagnosis. Designed for clinical use in radiology settings; provides improved access to medial, cranial, lateral, and axillary breast regions compared to previous models. Supports vacuum biopsy system interfaces.
Clinical Evidence
Bench testing only. Performance validated using NEMA MS 6-2001 standards for image quality and safety. Testing conducted on Siemens Avanto 1.5T system, representing the most critical engine for the 1.5T series. Conformance to IEC 60601-1 (general safety) and IEC 60601-2-33 (MRI safety) confirmed.
Technological Characteristics
4-channel phased array receive-only breast coil; factory pre-tuned. Patient rest with integrated immobilization and biopsy unit. Compatible with Siemens 1.5T MRI systems (Avanto, Espree, Tim Symphony, Sonata, Symphony). Complies with NEMA MS 6-2001, IEC 60601-1, and IEC 60601-2-33 standards.
Indications for Use
Indicated for female patients undergoing MR examination of the breast for diagnostic imaging and MR-guided biopsy or wire localization of lesions. To be used by trained physicians.
Regulatory Classification
Identification
A magnetic resonance diagnostic device is intended for general diagnostic use to present images which reflect the spatial distribution and/or magnetic resonance spectra which reflect frequency and distribution of nuclei exhibiting nuclear magnetic resonance. Other physical parameters derived from the images and/or spectra may also be produced. The device includes hydrogen-1 (proton) imaging, sodium-23 imaging, hydrogen-1 spectroscopy, phosphorus-31 spectroscopy, and chemical shift imaging (preserving simultaneous frequency and spatial information).
Special Controls
*Classification.* Class II (special controls). A magnetic resonance imaging disposable kit intended for use with a magnetic resonance diagnostic device only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.
Predicate Devices
MRI Devices Corporation Breast Array Coil Model OBC-63 ME (K002602)
Noras Immobilization and Biopsy Unit Model BI160 (K010570)
Noras Immobilization and Biopsy Unit Model BI160-PA (K052987)
Submission Summary (Full Text)
{0}------------------------------------------------
Section 9 510(k) summary
K081118
MAY - 2 2008
# SECTION 9
# 510(K) SUMMARY
Noras 510(k) Premarket Notification April 04, 2008 MR-BI320-PA 1.5T
{1}------------------------------------------------
#### MR-BI320-PA 1.5T
# Date of Summary Preparation: April 4, 2008
# This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR §807.92.
### 1. General Information
#### Importer/Distributor
#### Name and Address
Siemens Medical Solutions, Inc. 51 Valley Stream Parkway Malvern, PA 19355
#### Establishment Registration Number
2240869
#### Manufacturing Site
#### Name and Address
Noras MRI products GmbH
Leibnizstrasse 4
97204 Höchberg
Germany
#### Establishment Registration Number
Establishment Registration 3004929307
Owner/Operator 9071737
{2}------------------------------------------------
### 2. Contact Person
Martin Hempel Noras Röntgen- und Medizintechnik GmbH Leibnizstr. 4 97204 Höchberg, Germany
Telephone: (+49) 931/29927-29
Fax: (+49) 931/29927-20
Email Address: martin.hempel@noras.de
#### 3. Device Name and Classification
| Trade Name: | Noras Patient Rest MR BI320 1.5T |
|-----------------------|--------------------------------------|
| Common Name: | MR-BI320-PA 1.5T |
| Classification Name: | Magnetic Resonance Diagnostic Device |
| Classification Panel: | Radiology |
| CFR Number: | 21 CFR § 892.1000 |
| Device Class: | II |
| Product Code: | 90MOS and LNH |
#### 4. Device Description
The MR-BI320-PA 1.5T is a patient rest with a immobilization- and biopsy unit and a 4-channel phased array receive only coil.
The coil is factory pre-tuned to the fixed load and no further tuning or matching is required for the patient.
The coil is divided into two spherical parts. Each half contains a 2 channel receive only arrav.
The upper coil is connected with a cable and a plug with the insertion coil. The insertion plate coil is connected to the scanner with a cable connection.
The insertion plate coil is designed to enable insertion of immobilization and biopsy system and is inserted into the patient rest.
The upper coil (patient pad coil) serves as a positioning pad for the patient at the same time.
{3}------------------------------------------------
ﻡ ﺍ
#### 5. Intended Use
The intended use of the Noras MR-BI320-PA 1.5T is, in conjunction with a Magnetic sa a discussion in the MR examination of the female breast. It is indicated for use images of the imaging device to produce transverse, sagittal, coronal and obligue images of the internal structures of the female breast. When interpreted by a trained physician, these images provide information that can be useful in determining diagnosis.
The included Breast Biopsy Unit Bl160-2 permits MR guided breast biopsy and wire localization of lesions that can be performed by a trained physician.
#### 6. Substantial Equivalence
Noras believes that, within the meaning of the Safe Medical Devices Act of 1990, the 4channel phased array Breast Coil 1.5T of the MR-BI320-PA 1.5T is substantially equivalent to the following coil;
| Coil Name | Premarket Notification | Clearance Date |
|-----------------------------------------------------------------|------------------------|--------------------|
| MRI Devices Corporation<br>(Now Known as Invivo<br>Corporation) | K002602 | September 08, 2000 |
| Breast Array Coil<br>Model OBC-63 ME | | |
The immobilization and biopsy unit BI160-2 is a redesigned model due to the dimensions of the patient rest of the following Noras Immobilization and Biopsy units.
| Immobilization and Biopsy<br>Unit | Premarket Notification | Clearance Date |
|-----------------------------------------------------------|------------------------|------------------|
| Noras Immobilization and<br>Biopsy Unit<br>Model BI160 | K010570 | April 09, 2001 |
| Noras Immobilization and<br>Biopsy Unit<br>Model BI160-PA | K052987 | November 08,2005 |
{4}------------------------------------------------
The immobilization and biopsy unit BI320-DC is a redesigned model of the predicate devices mentioned before to achieve a cranial access to both breast at one time,
| Immobilization and Biopsy<br>Unit | Pemarket Notification | Clearance Date |
|-----------------------------------------------------------|-----------------------|------------------|
| Noras Immobilization and<br>Biopsy Unit<br>Model BI160 | K010570 | April 09, 2001 |
| Noras Immobilization and<br>Biopsy Unit<br>Model BI160-PA | K052987 | November 08,2005 |
# 7. Summary of Technological Characteristics of the Principal Device as Compared with the predicate Devices
The MRI (now Invivo) 4 channel OBC (Open Breast Coil) has been designed to examine the female breast. The patient lies in prone position on top of the coil, which is designed as a patient rest. Cushions complete the set for a comfortable patient positioning. In combination with the Noras BI160 the immobilization of the breast it is achieved to avoid moving artifacts during the scan. A biopsy can be taken by using the post and piller or grid localization system to guide the needle under MR control to the lesion.
The Noras BI160-PA is a patient rest, including a immobilization and biopsy unit without an integrated coil. To get MR Images it is mandatory to use the loop coils of the MRT System manufacturer. The approach of this new product was, to give the physician a more comfortable access to the region of interest in the female breast (medial, cranial and lateral). and even the higher, alary near positions.
The Noras MR-BI320-PA 1.5T comes along with a 4 channel breast coil for 1.5T Siemens MRT systems (Avanto, Espree, Tim Symphony, Sonata and Symphony). The dedicated 4 channel 1.5T breast coil enables a MR guided biopsy under comparable picture quality as the MRI OBC coil (see Appendix C Test Protocols, due to Standard NEMA MS 6-2001) and the advantages on the intervention side of the Noras BI160-PA.
Today it becomes more and more common to use vacuum biopsy systems to get the tissue samples out of the region of interest for examination in the laboratory. Therefore different interfaces or adapters have been developed for the Noras biopsy units. These accessories are equal to the standard parts, with the exception of the hole diameters.
{5}------------------------------------------------
# 8. General Safety and Effectiveness Concerns
The complete system MR-BI320-PA 1.5T will conform the harmonized standard of IEC 60601-1 3rd edition, Medical electrical equipment - General requirements for basic safety and essential performance.
The MR-BI320-PA 1.5T coil will conform to the FDA recognized NEMA Standards for the measurement of performance and safety parameters and the IEC standards for safety issues with the Magnetic Resonance Imaging Devices, IEC 60601-2-33: 2002. This will assure that the performance of this device can be considered safe and effective when used with the currently available MAGNETOM 1.5T systems.
All tests are performed on the Siemens Avanto. This is the most critical engine for safety and performance of the Siemens 1.5T series. Passing these tests gives the Siemens approval for the complete 1.5T series.
# 9. Conclusion as to Substantial Equivalence
Noras believes that, within the definition of the Safe Medical Devices Act of 1990, the Noras 4-channel phased array Breast coil 1.5T with its patient rest and immobilization and biopsy units is substantially equivalent to the predicate devices list and milli
Signature
Hubert Noras President
April 4, 2008
{6}------------------------------------------------
Image /page/6/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three stripes forming its body and wing. The eagle is positioned to the right of a circular seal that contains the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAY - 2 2008
Noras MRI Products GmbH % Mr. Stefan Preiss Responsible Third Party Official TÜV SÜD Am erica 1775 Old Hwy 8 NW, Ste 104 NEW BRIGHTON MN 55112-1891
Re: K081118
Trade/Device Name: Noras MR-BI320-PA 1.5T Regulation Number: 21 CFR 892.1000 Regulation Name: Magnetic resonance diagnostic device Regulatory Class: II Product Code: MOS Dated: April 16, 2008 Received: April 21, 2008
#### Dear Mr. Preiss:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and ' adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register,
{7}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of this Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter.
| | 21 CFR 876.xxxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
|--|-----------------|----------------------------------|--------------|
| | 21 CFR 884.xxxx | (Obstetrics/Gynecology) | 240-276-0115 |
| | 21 CFR 892.xxxx | (Radiology) | 240-276-0120 |
| | Other | | 240-276-0100 |
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrb/industry/support/index.html.
Sincerely yours,
Nancy C. Brogdon
Nancy C. Brogdon Director, Division of Reproductive. Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{8}------------------------------------------------
### Indications for Use
510(k) Number (if known):
Device Name: __Noras MR-BI320-PA 1.5T
Indications for Use:
The intended use of the Noras MR-BI320-PA 1.5T is, in conjunction with a Magnetic Resonance Scanner, the MR examination of the female breast. It is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images of the internal structures of the female breast. When interpreted by a trained physician, these images provide information that can be useful in determining diagnosis.
The included Breast Biopsy Unit Bl160-2 permits MR guided breast biopsy, wire localization of lesions that can be performed by a trained physician.
Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nomithmthn
Division of Reproductive, Abdominal and Radiological Devices 510(k) Number
(Posted November 13, 2003)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.