JNE IMPLANT SYSTEM
Device Facts
| Record ID | K072425 |
|---|---|
| Device Name | JNE IMPLANT SYSTEM |
| Applicant | GC America, Inc. |
| Product Code | DZE · Dental |
| Decision Date | Mar 10, 2008 |
| Decision | SESE |
| Submission Type | Abbreviated |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The JNE Implant System is a titanium alloy screw-type endosseous dental implant and endosseous dental implant abutment, which is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for a prosthetic device, such as an artificial tooth, in order to restore a patient's chewing function.
Device Story
JNE Implant System is a screw-type endosseous dental implant and abutment system. Components are surgically placed into the upper or lower jaw bone by a dental professional to support prosthetic devices like artificial teeth. The system restores patient chewing function. The device is manufactured from Ti-6Al-4V ELI alloy; fixtures feature a sandblasted and acid-etched surface treatment. Abutments connect to fixtures via a tapered-joint interface.
Clinical Evidence
Bench testing only. No clinical data provided.
Technological Characteristics
Material: Ti-6Al-4V ELI alloy. Design: Screw-type fixture with tapered-joint abutment connection. Surface treatment: Sandblast and acid etching. Sterilization: Not specified (facility listed).
Indications for Use
Indicated for patients requiring dental restoration via endosseous implants in the upper or lower jaw arches to support prosthetic devices (artificial teeth) and restore chewing function.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Predicate Devices
- ENDOPORE ENDOSSEOUS DENTAL IMPLANT SYSTEM (K971196)
- ASTRA TECH IMPLANTS - DENTAL SYSTEM (K002513)
- STRAUMANN DENTAL IMPLANT SYSTEM (K033984)