K071735 · Symbios Medical Products, LLC · MEB · Jul 19, 2007 · General Hospital
Device Facts
Record ID
K071735
Device Name
MODIFICATION TO DISPOSABLE INFUSION PUMP KIT
Applicant
Symbios Medical Products, LLC
Product Code
MEB · General Hospital
Decision Date
Jul 19, 2007
Decision
SESE
Submission Type
Special
Regulation
21 CFR 880.5725
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Symbios Disposable Infusion Pump Kit is a disposable, self-contained infusion system utilizing an inflatable elastomeric reservoir to mechanically provide percutaneous infusion of prescribed solutions at a pre-set rate for post-operative pain management.
Device Story
Disposable infusion pump kit; provides temporary percutaneous infusion of prescribed solutions. System components: elastomeric pump, catheter needle/introducer, infusion catheter, accessories. Principle of operation: inflatable elastomeric reservoir mechanically pressurizes fluid; drives fluid through tubing to small restrictor; provides continuous infusion at pre-set rate. Used in general hospital setting or home; operated by healthcare professionals or patients. Output: continuous infusion of medication for post-operative pain management. Benefits: enables outpatient pain management following arthroscopic surgery; reduces need for hospital stay. Device supplied empty; no specific drug references in labeling.
Clinical Evidence
No clinical data. Bench testing only. Performance verified for 150 ml fill volume and flow rate accuracy (± 15%).
Technological Characteristics
Elastomeric pump; synthetic rubber latex-free membrane; PVC tubing; stainless steel needle; Teflon or polyethylene introducer catheter. Flow control via fixed orifice. Sterilization: EtO per ANSI/AMMI/ISO 11135-1994. Packaging: Tyvek/polymylar pouches.
Indications for Use
Indicated for post-operative pain management in patients requiring percutaneous infusion of prescribed solutions. Not for delivery of blood, blood products, lipids, or fat emulsions.
Regulatory Classification
Identification
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
{0}------------------------------------------------
# JUL 1 9 2007
# 510(k) SUMMARY
Submitters Name: Michael James, Director of Quality Symbios Medical Products, LLC 7301 Georgetown Road, Suite 150 Indianapolis, IN 46268 Office: 317-225-4447 Mobile: 812-521-7074 Fax: 317-225-4451
Contact Person: Same as submitter. Facility Registration Number: 3005203102 Date Summary Prepared: May 1, 2007
#### IDENTIFICATION OF MODIFIED DEVICE
Trade Name: Disposable Infusion Pump Kit Common Name: Disposable Infusion Pump Kit Panel: General Hospital
#### Classification Name and Reference:
Pump
Pump, Infusion, Elastomeric, External (21 CFR 880.5725) Device Classification for the subject and/or predicate devices: Class II Device Panel Code: 80 Device Product Code: MEB
Catheter Needle/Introducer Catheter, Accessories (21 CFR 878.4200) Device Classification for the predicate devices: Class | Exempt Device Panel Code: 79 Device Product Code: KGZ
Infusion Catheter
Catheter, Conduction, Anesthetic (21 CFR 868.5120) Device Classification for the subject and/or predicate devices: Class II Device Panel Code: 73 Device Product Code: BSO
{1}------------------------------------------------
## IDENTIFICATION OF THE LEGALLY MARKETED DEVICE
Trade Name: Disposable Infusion Pump Kit Common Name: Disposable Infusion Pump Kit 510(k) Number: K051474 Panel: General Hospital
## Classification Name and Reference:
Pump
Pump, Infusion, Elastomeric, External (21 CFR 880.5725) Device Classification for the subject and/or predicate devices: Class II Device Panel Code: 80 Device Product Code: MEB
Catheter Needle/Introducer
Catheter, Accessories (21 CFR 878.4200) Device Classification for the predicate devices: Class I Exempt Device Panel Code: 79 Device Product Code: KGZ
Infusion Catheter
Catheter, Conduction, Anesthetic (21 CFR 868.5120) Device Classification for the subject and/or predicate devices: Class II Device Panel Code: 73 Device Product Code: BSO
## DESCRIPTION OF THE DEVICE
Infusion of liquids into a patient in the general hospital setting as well as at home is frequently required in medical treatment. For example, in orthopedics a disposable device is often indicated after outpatient arthroscopic surgery in order to infuse local anesthetics for several days following the patient's return home. The infusion catheter is usually removed when the patient returns to the physician's office for a follow-up visit.
The Symbios Disposable Infusion Pump Kit is a convenience kit that includes the components necessary to provide temporary infusion of a liquid into a patient. The components of the system are an elastomeric pump, a catheter needle/introducer, an infusion catheter and accessories. The pump is a disposable, self-contained, infusion system utilizing an inflatable elastomeric reservoir to mechanically pressurize a fluid and drive it through tubing to a small restrictor to provide infusion at a pre-set rate.
The device is provided empty and no specific drug references are made in the labeling. The device is not intended for delivery of blood, blood products, lipids or fat emulsions.
{2}------------------------------------------------
## INTENDED USE OF THE DEVICE
(Same for both the modified and unmodified predicate device)
The Symbios Disposable Infusion Pump Kit is a disposable, self-contained infusion system utilizing an inflatable elastomeric reservoir to mechanically provide percutaneous infusion of prescribed solutions at a pre-set rate for post-operative pain management.
## NEW DEVICE IN COMPARISON WITH PREDICATE DEVICE
Minor modifications have been made to the Disposable Infusion Pump Kit cleared in 510(k) Number K051474.
- 1. The fill volume has been increased from 100 ml to 150 ml. The design (dimensions, materials, assembly methods) of the pump remains unchanged. Note - The design of the predicate device was capable of a 150 ml fill volume, but only tested and verified to 100 ml. Diagrams of the modified and predicate pump assemblies are shown in Attachment 2.
- 2. The catheter needle/introducer included in the kit has been extended to include needle/introducers that are as long as 10 inches in length, and up to 14 gauge (GA) in diameter. The increased size is needed for patients with larger bodies. The needle material remains stainless steel, while the introducer catheter material could be either Teflon or polyethylene.
| | Modified Device | Predicate Device |
|--------------------|------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------|
| 510(k) Number | New | K051474 |
| Manufacturer | Symbios Medical Products, LLC | Symbios Medical Products, LLC |
| Type | Elastomeric Pump | Elastomeric Pump |
| Fluid Reservoir | Sold empty and capable of being<br>filled via a fill port | Sold empty and capable of being<br>filled via a fill port |
| Reservoir Material | Synthetic rubber, latex-free<br>elastomeric membrane | Synthetic rubber, latex-free<br>elastomeric membrane |
| Pressure Source | Strain energy of elastomeric<br>membrane | Strain energy of elastomeric<br>membrane |
| Fill Volume | 150 ml | 100 ml |
| Flow Rate | 2.0 ml/hr | 2.0 ml/hr |
| Flow Profile | Continuous | Continuous |
| Accuracy | ± 15% | ± 15% |
| Power Requirement | None | None |
| Tubing | Integrated | Integrated |
| Tubing Material | PVC | PVC |
| Flow Control | Consistent flow rate throughout the<br>entire course of therapy is achieved<br>by orifice size (no change) | Consistent flow rate throughout the<br>entire course of therapy is achieved<br>by orifice size |
| Safety Features | Fixed Flow rate tubing prevents fluid<br>runaway conditions. Each | Fixed Flow rate tubing prevents fluid |
| | administration set is supplied with a<br>clamp to stop the infusion if<br>necessary. (no change) | runaway conditions. Each<br>administration set is supplied with a<br>clamp to stop the infusion if<br>necessary. (no change) |
## Pump
{3}------------------------------------------------
## Catheter Needle/Introducer
| | Modified Device | Predicate Device |
|--------------------------------|------------------------|-------------------|
| FDA Status | Exempt (878.4200) | Exempt (878.4200) |
| Sponsor/Manufacturer | Martech | Martech |
| Material - Needle | Stainless Steel | Stainless steel |
| Material - Introducer Catheter | Teflon or Polyethylene | Teflon |
| Needle Size | Up to 14 GA | 16 GA |
| Needle Length | Up to 10" | 2.75" |
### STERILITY INFORMATION
EtO sterilization with the following parameters:
Sterility Assurance Level: 10-6
Sterility Validation Method: ANSI/AMMI/ISO 11135-1994
The maximum levels of residuals allowable:
| Ethylene Oxide (EtO) | <25ppm |
|-----------------------|---------|
| Ethylene Chlorohydrin | <25ppm |
| Ethylene Glycol | <250ppm |
Packaging Description: The kit will be packaged in a sealed Tyvek/polymylar pouch, and then placed with the Directions for Use inside another larger sealed Tyvek/polymylar pouch.
Labeling: All packages will display a statement that the device has been sterilized by EtO
{4}------------------------------------------------
Image /page/4/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized eagle with three lines forming its body and wings. The text "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" is arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUL 1 9 2007
Mr. Michael James Director of Quality Symbios Medical Products, LLC 7301 Georgetown Road, Suite 150 Indianapolis, Indiana 46268
Re: K071735
Trade/Device Name: Disposable Infusion Pump Kit Regulation Number: 21 CFR 880.5725 Regulation Name: Infusion Pump, Introduction/drainage Catheter, Anesthesia Conduction Catheter Regulatory Class: II Product Code: MEB, KGZ, BSO Dated: June 25, 2007 Received: June 27, 2007
Dear Mr. James:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
Page 2 -Mr. James
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801). please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
Carls
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
# ATTACHMENT 1
## Indications for Use
K071735 510(k) Number: _ _ _ _ _ _
Device Name: Disposable Infusion Pump Kit
Indications for Use:
The Disposable Infusion Pump is a disposable, self-contained infusion system utilizing an inflatable elastomeric reservoir to mechanically provide percutaneous infusion of prescribed solutions at a preset rate for post-operative pain management.
X ____________________________________________________________________________________________________________________________________________________________________________ Prescription Use (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) のお気になる。
Concurrence of CDRH, Office of Device Evaluation (ODE)
Cunt ca
(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: K421235
Page 1 of
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.