← Product Code [MWJ](/productcode/MWJ) · K071733

# DL900 SERIES HOLTER RECORDER (K071733)

_Braemar, Inc. · MWJ · Jul 24, 2007 · Cardiovascular · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K071733

## Device Facts

- **Applicant:** Braemar, Inc.
- **Product Code:** [MWJ](/productcode/MWJ.md)
- **Decision Date:** Jul 24, 2007
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 870.2800
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular

## Indications for Use

The DL900 Series Holter Recorder is intended for patients requiring ambulatory (Holter) monitoring. Such monitoring is most frequently used for the indications below: - Evaluation of symptoms suggesting arrhythmia or myocardial ischemia. 1. - Evaluation of ECG documenting therapeutic interventions in individual patients or 2. groups of patients. - Evaluation of patients for ST segment changes. 3. - 4. Evaluation of a patient's response after resuming occupational or recreational activities (e.g., after M.I. or cardiac surgery.) - Clinical and epidemiological research studies. ನ. - 6. Evaluation of patients with pacemakers. - Reporting of time and frequency domain heart rate variability. 7. - Reporting of QT Interval 8.

## Device Story

DL900 Series Holter Recorder captures ambulatory ECG signals from patients; device records cardiac electrical activity over extended periods. Used in clinical settings or by patients in ambulatory environments; operated by healthcare professionals or patients under physician guidance. Device stores ECG data for subsequent transfer to analysis systems; output allows clinicians to assess cardiac rhythm, ST segment changes, and heart rate variability. Data facilitates diagnosis of arrhythmias, monitoring of therapeutic interventions, and evaluation of pacemaker performance. Benefits include improved detection of transient cardiac events and assessment of patient recovery post-cardiac surgery or myocardial infarction.

## Clinical Evidence

No clinical data provided; substantial equivalence based on technological characteristics and intended use.

## Technological Characteristics

Ambulatory Holter recorder; digital ECG signal acquisition; intended for continuous cardiac monitoring. Device form factor designed for patient wearability. Connectivity involves data transfer to external analysis systems. Software-based recording and storage.

## Regulatory Identification

A medical magnetic tape recorder is a device used to record and play back signals from, for example, physiological amplifiers, signal conditioners, or computers.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized image of three human profiles facing right, stacked on top of each other. The profiles are black and have a flowing, wave-like design at the bottom. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the image.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

JUL 2 4 2007

Braemar, Inc. c/o Mr. Darren Dershem Regulatory Affairs Representative 1285 Corporate Center Drive, Suite 150 Eagan, MN 55121

Re: K071733

> Trade/Device Name: Model DL900 Series Holter Recorder Regulation Number: 21 CFR 870.2800 Regulation Name: Medical magnetic tape recorder Regulatory Class: Class II Product Code: MWJ Dated: June 18, 2007 Received: June 26, 2007

Dear Mr. Dershem:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{1}------------------------------------------------

Page 2 - Mr. Darren Dershem

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Bhimmar for

Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

## Indications for Use

510(k) Number (if known):

Device Name: Braemar DL900 Series Holter Recorder

Indications For Use:

The DL900 Series Holter Recorder is intended for patients requiring ambulatory (Holter) monitoring. Such monitoring is most frequently used for the indications below:

- Evaluation of symptoms suggesting arrhythmia or myocardial ischemia. 1.
- Evaluation of ECG documenting therapeutic interventions in individual patients or 2. groups of patients.
- Evaluation of patients for ST segment changes. 3.
- 4. Evaluation of a patient's response after resuming occupational or recreational activities (e.g., after M.I. or cardiac surgery.)
- Clinical and epidemiological research studies. ನ.
- 6. Evaluation of patients with pacemakers.
- Reporting of time and frequency domain heart rate variability. 7.
- Reporting of QT Interval 8.

Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Blummo

Page 1 of

---

**Source:** [https://fda-staging.innolitics.com/device/K071733](https://fda-staging.innolitics.com/device/K071733)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
