← Product Code [EIA](/productcode/EIA) · K071485

# TPC ADVANCECAM INTRA ORAL CAMERA SYSTEM, MODEL AIC 888 (K071485)

_Tpc Advanced Technology, Inc. · EIA · Aug 28, 2007 · Dental · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K071485

## Device Facts

- **Applicant:** Tpc Advanced Technology, Inc.
- **Product Code:** [EIA](/productcode/EIA.md)
- **Decision Date:** Aug 28, 2007
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 872.6640
- **Device Class:** Class 1
- **Review Panel:** Dental

## Indications for Use

AdvanceCAM intra oral camera system and accessories is indicated for use to provide the dentist and the patient with a view of the mouth before and after the dental procedure, which assists the dentist in decribing the dental procedure being performed as well as showing the results

## Device Story

AdvanceCAM Intra Oral Camera System captures intraoral images for patient education and procedure documentation; consists of optic units, docking stations, and analog-to-digital converters; wireless and wired configurations available. Used in dental clinics by dentists; provides real-time visual feedback to patients and practitioners. Facilitates communication regarding dental procedures and treatment outcomes. System components include optic units (AIC 888, AIC 899), docking stations (AIC 810, AIC 650, AIC 600, AIC 805, AIC 825), wireless docking stations (AIC 665, AIC 815, AIC 835), analog-to-digital converters (AIC 700, AIC 720, AIC 750), wireless analog-to-digital converter (AIC 705), and wireless transmitter (AIC 900).

## Clinical Evidence

No clinical data provided; device relies on technological equivalence to existing dental intraoral camera systems.

## Technological Characteristics

Intraoral camera system comprising optic units, docking stations, and analog-to-digital converters. Includes wireless and wired transmission capabilities. Designed for dental operative environments. Class I device under 21 CFR 872.6640.

## Regulatory Identification

A dental operative unit and accessories is an AC-powered device that is intended to supply power to and serve as a base for other dental devices, such as a dental handpiece, a dental operating light, an air or water syringe unit, and oral cavity evacuator, a suction operative unit, and other dental devices and accessories. The device may be attached to a dental chair.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/0/Picture/1 description: The image is a black and white logo for the U.S. Department of Health and Human Services. The logo features a stylized caduceus symbol, which is a staff with two snakes coiled around it. The symbol is surrounded by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement. The text is written in a simple, sans-serif font.

Public Health Service

JAN - 8 2008

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Mr. Scott Beckley Vice President TPC Advanced Technology, Incorporated 18525 East Gale Avenue City of Industry, California 91748

Re: K071485

Trade/Device Name: AdvanceCAM Intra Oral Camera System and Accessories Regulation Number: 21 CFR 872.6640 Regulation Name: Dental Operative Unit and Accessories Regulatory Class: I Product Code: EIA Dated: April 17, 2007 Received: May 30, 2007

Dear Mr. Beckley:

This letter corrects our substantially equivalent letter of August 28, 2007.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{1}------------------------------------------------

## Page 2 - Mr. Beckley

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

Sutta Y. Michin Davis

Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

Page 3 – Mr. Beckley

AdvanceCAM Intra Oral Camera System and accessories found to be substantially equivalent:

| MODEL   | DESCRIPTION                          |
|---------|--------------------------------------|
| AIC 888 | Optic unit                           |
| AIC 810 | Docking station                      |
| AIC 700 | Analog to digital converter          |
| AIC 705 | Wireless analog to digital converter |
| AIC 720 | Analog to digital converter          |
| AIC 750 | Analog to digital converter          |
| AIC 650 | Docking station                      |
| AIC 665 | Wireless docking station             |
| AIC 600 | Docking station                      |
| AIC 900 | Wireless transmitter                 |
| AIC 805 | Docking station                      |
| AIC 815 | Wireless docking station             |
| AIC 899 | Optic unit                           |
| AIC 835 | Wireless docking station             |
| AIC 825 | Docking station                      |

:

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows a logo with the letters "TPC" in a stylized font. Below the letters, the words "UNITED TECH" are written in a smaller, blockier font. The logo appears to be for a technology company, given the "TECH" abbreviation. The background is dark, which makes the logo stand out.

18525 E. Gale Ave. City of Industry, CA 91748 800.560.8222 626.810.4337 Fax: 626.810.4245

Dental Equipment Manufacturer Chairs, Units, Lights, Intraoral Cameras, etc.

## Indications for Use

510(k) Number (if known):

Device Name:

AdvanceCAM Intra Oral Camera System and accessories

Indications for Use:

AdvanceCAM intra oral camera system and accessories is indicated for use to provide the dentist and the patient with a view of the mouth before and after the dental procedure, which assists the dentist in decribing the dental procedure being performed as well as showing the results

Prescription Use W (Part 21 CFR 801 Subpart D)

and/or

Over-the-Counter Use (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE- CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Savar Kumar

(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices

510(k) Number: K071485

w w w . t p c d e n t a l . c o m

---

**Source:** [https://fda-staging.innolitics.com/device/K071485](https://fda-staging.innolitics.com/device/K071485)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
