GOPHER 2F SUPPORT CATHETER, MODEL 5600 AND GOPHER 3F SUPPORT CATHETER, MODEL 5610
K070372 · Vascular Solutions, Inc. · DQY · Jun 1, 2007 · Cardiovascular
Device Facts
Record ID
K070372
Device Name
GOPHER 2F SUPPORT CATHETER, MODEL 5600 AND GOPHER 3F SUPPORT CATHETER, MODEL 5610
Applicant
Vascular Solutions, Inc.
Product Code
DQY · Cardiovascular
Decision Date
Jun 1, 2007
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.1250
Device Class
Class 2
Indications for Use
The Gopher Support Catheter is intended to be used in conjunction with steerable guidewires in order to access discreet regions of the arterial and/or coronary vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic or therapeutic agents.
Device Story
Gopher Support Catheter is a percutaneous catheter used in arterial/coronary vasculature. It functions as a conduit for steerable guidewires, facilitating placement/exchange of interventional devices and subselective delivery of diagnostic/therapeutic agents. Operated by physicians in clinical settings, the device is compatible with ≥6F guide catheters and ≤0.014" guidewires. It features a polymeric outer layer, laser-cut Nitinol middle layer, and PTFE/polyimide inner liner. Radiographic visualization is provided by a markerband (2F) or threaded stainless steel distal tip (3F). The device includes a luer hub, strain relief, and adjustable torque device. By providing structural support and trackability, it assists clinicians in navigating complex vascular anatomy, potentially improving procedural success in interventional cardiology.
Clinical Evidence
No clinical data. Bench testing only. Testing included visual inspection, torque strength, kink resistance, guide catheter/guidewire interface, fluid/air leak, flow rate, and bond strength. Biocompatibility testing performed per ISO 10993 (cytotoxicity, sensitization, reactivity, systemic toxicity, hemocompatibility).
Indicated for patients requiring access to discrete regions of arterial and/or coronary vasculature for guidewire/device placement, exchange, or subselective infusion of diagnostic/therapeutic agents.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
{0}------------------------------------------------
# 0. Lots
## 510(k) Summary (As required by 21 CFR 807.92(c))
JUN - 1 2007
K070372 510(k) Number: ____
Date Prepared
May 29, 2007
#### Submitter Information
| Submitter's Name: | Vascular Solutions, Inc. |
|-------------------|----------------------------------------------|
| Address: | 6464 Sycamore Court<br>Minneapolis, MN 55369 |
Julie Tapper Contact Person: Senior Regulatory Affairs Associate Phone 763-656-4228 Fax 763-656-4253
#### Device Information
| Trade Name: | Gopher™ Support Catheter |
|----------------------|--------------------------------------------------------------|
| Common Name: | Percutaneous catheter |
| Class: | II |
| Classification Name: | Percutaneous catheter<br>(21 CFR 870.1250, Product Code DQY) |
#### Predicate Devices
Skyway™ Support Catheter (K052258 and K060327), manufactured by Vascular Solutions, Inc.
Tornus Support Catheter (K051772), manufactured by Asahi Intecc Co., Ltd.
#### Device Description
The Gopher catheter is available in two sizes-2F and 3F. Each catheter assembly has a polymeric outer layer and Nitinol middle layer that extend the length of the catheter. a porfilerie oud, the Nitinol tubing is laser cut and is lined with a PTFE/polyimide inner layer. To provide a radiographic means of locating the tip, the 2F size has a radiopaque markerband near the distal tip and the 3F distal tip is a segment of threaded, radiopaque stainless steel.
{1}------------------------------------------------
Each catheter has printed positioning marks at 95cm and 105cm from the catheter's distal tip, a luer hub and strain relief on the proximal end, and an adjustable torque device near the proximal end. Each Gopher catheter model is compatible with ≥6F guide catheters and ≤0.014" guidewires and has a working length of approximately 135cm.
The Gopher catheter is provided sterile and intended for a single use.
#### Intended Use/Indications for Use
The Gopher Support Catheter is intended to be used in conjunction with steerable guidewires in order to access discreet regions of the arterial and/or coronary vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic or therapeutic agents.
#### Summary of Non-clinical Testing
Bench testing was conducted on the Gopher catheter, including the packaging, and included an assessment of the physical properties of the device and its ability to achieve its intended use. The results of the tests confirmed the suitability of the device for its intended use. Each bench test that was conducted is listed, below.
| Visual Inspection | Torque Device-to-shaft Interface |
|-----------------------------------|----------------------------------------------------------------|
| Guidewire Interface | Hub-to-proximal shaft Bond Strength |
| Tortuosity | Distal Shaft Bond Strength |
| Catheter Kink Resistance | Markerband Visibility (2F) |
| Guide Catheter Interface | Radiopaque Distal Tip (3F) |
| Fluid Leak Under Pressure | Packaging-Pouch Visual Appearance after Distribution Testing |
| Air Leak During Aspiration | Packaging-Product Containment after Distribution Testing |
| Flow Rate | Packaging-Product Visual Appearance after Distribution Testing |
| Catheter Integrity After Torquing | Packaging-Label Legibility after Distribution Testing |
| Torque Strength | |
In addition, the biocompatibility of the Gopher catheter was assessed in accordance with ISO 10993, "Biological Evaluation of Medical Devices." The testing confirmed that the materials and processes used in the manufacture of the Gopher catheters are biocompatible. The tests that were conducted are listed, below.
| Cytotoxicity | Hemocompatibility, hemolysis |
|---------------------------|----------------------------------------------------------|
| Sensitization | Hemocompatibility, Prothrombin Time |
| Intracutaneous Reactivity | Hemocompatibility, Lee White Coagulation Test |
| Acute Systemic Toxicity | Hemocompatibility, In vitro Hemocompatibility Assessment |
| Material Mediated Pyrogen | |
#### Summary of Clinical Testing
Clinical evaluations were not required for this device.
{2}------------------------------------------------
K070372 p. 30f 3
#### Statement of Equivalence
The Gopher catheter is substantially equivalent to the currently marketed Skyway and Tornus catheters, based on comparisons of the device classifications, indications for use, technological characteristics, and sterilization methods.
#### Conclusion
The Gopher catheter is substantially equivalent to the currently marketed Skyway and Tornus catheters, based on comparisons of the device classifications, indications for use, technological characteristics, and sterilization methods. Bench tests confirmed the suitability of the device for its intended use.
{3}------------------------------------------------
Public Health Service
Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with its wings spread, and the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circular pattern around the eagle. The logo is black and white.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
JUN - 1 2007
Vascular Solutions, Inc. c/o Ms. Julie Tapper Senior Regulatory Affairs Associate 6464 Sycamore Court Minneapolis, MN 55369
Re: K070372
Gopher™ Support Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous catheter Regulatory Class: II (two) Product Code: DOY Dated: May 16, 2007 Received: May 21, 2007
Dear Ms. Tapper:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 - Ms. Julie Tapper
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
C.S.N.
Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
### Indications for Use Statement
510(k) Number: ___ K070372
Device Name:
Gopher™ Support Catheter
#### Indications for Use:
The Gopher Support Catheter is intended to be used in conjunction with steerable guidewires in order to access discreet regions of the arterial and/or coronary vasculature. It may be used to facilitate placement and exchange of guidewires and other interventional devices and to subselectively infuse/deliver diagnostic or therapeutic agents.
Prescription Use X (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE --CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
QSSM
(Division Sign-Off) Division of Cardiovascular Devices
510(k) Number K070372
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.