PICCOLIGHT E50,PICCOLIGHT E56,EUROLIGHT E10, EUROLIGHT E30, AND EUROLIGHT E36
K070270 · Kirchner & Wilhelm GmbH + Co.Kg · HLJ · Nov 5, 2007 · Ophthalmic
Device Facts
Record ID
K070270
Device Name
PICCOLIGHT E50,PICCOLIGHT E56,EUROLIGHT E10, EUROLIGHT E30, AND EUROLIGHT E36
Applicant
Kirchner & Wilhelm GmbH + Co.Kg
Product Code
HLJ · Ophthalmic
Decision Date
Nov 5, 2007
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 886.1570
Device Class
Class 2
Indications for Use
An ophthalmoscope is intended to be used to examine the cornea, aqueous, lens, vitreous and retina of the eye.
Device Story
Battery-powered handheld ophthalmoscopes (Piccolight E50/E56, Eurolight E10/E30/E36) used by clinicians to examine eye structures (cornea, aqueous, lens, vitreous, retina). Devices utilize vacuum or halogen bulbs (2.5V) to illuminate the eye; examiner views structures through a lens system with adjustable dioptre settings (-20 to +20). Piccolight models feature PA 6 GF 30% plastic handles; Eurolight models feature metal handles. Aperture configurations vary by model (single vs. six-aperture including slit, small/large circle, semi-circle, red-free, and fixing cross). Devices are operated manually by clinicians in clinical settings. Output is direct visualization of the ocular fundus, aiding in diagnosis of ocular conditions. Benefit includes non-invasive, portable visualization of internal eye structures.
Clinical Evidence
Bench testing only. Devices conform to ISO 10942 (ophthalmoscopes), IEC 60601-1 (general safety), and IEC 60601-1-2 (electromagnetic compatibility). No clinical data provided.
Technological Characteristics
Battery-powered handheld ophthalmoscopes. Materials: Polyamide 6 GF30% (Piccolight) or metal (Eurolight). Illumination: 2.5V vacuum or halogen bulbs. Dioptre range: -20 to +20. Apertures: 1 or 6 configurations. Standards: ISO 10942, IEC 60601-1, IEC 60601-1-2. No software or connectivity.
Indications for Use
Indicated for examination of the cornea, aqueous, lens, vitreous, and retina of the eye in patients requiring ophthalmoscopic evaluation. Prescription use only.
Regulatory Classification
Identification
An ophthalmoscope is an AC-powered or battery-powered device containing illumination and viewing optics intended to examine the media (cornea, aqueous, lens, and vitreous) and the retina of the eye.
Special Controls
*Classification.* Class II (special controls). The device, when it is an AC-powered opthalmoscope, a battery-powered opthalmoscope, or a hand-held ophthalmoscope replacement battery, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 886.9.
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows a handwritten string of characters, "K070270". The characters are written in black ink on a white background. The handwriting is somewhat stylized, with the 'K' having a distinct shape.
NOV - 5 2007
Image /page/0/Picture/3 description: The image is a logo for a company called "KaWe Medizintechnik". The logo is a black parallelogram with the word "KaWe" in white letters at the bottom. Above the word "KaWe" is the word "MEDIZINTECHNIK" in smaller white letters. The background of the parallelogram is black.
KIRCHNER & WILHELM
GmbH + Co.
| Name and address of sponsor of the<br>510(k) submission: | Kirchner & Wilhelm GmbH & Co. KG<br><br>Eberhardstrasse 56<br>71679 Asperg<br>Germany |
|------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------|
| Official contact person for all<br>correspondence: | Matthias Dubb<br>Phone: 49 7141 68188-70<br>Fax: 49 7141 68188-74<br>E-mail: Matthias.dubb@Kirchner & Wilhelm med.de |
| Date Prepared: | January 26, 2007 |
| Device Name: | Piccolight® E50, Piccolight® E56, Eurolight® E10,<br>Eurolight® E30, Eurolight® E36 |
| Generic name of the device: | Ophthalmoscope, battery-powered |
| Classification, Product Code and<br>CFR Regulation Number: | Class II<br>HLJ<br>21 CFR 886.1570 |
| Classification Panel: | Ophthalmic |
| Predicate Device Names and 510(k) numbers: | Uni II (K925756) |
| | RI-MINI (K932503) |
| | Ophthalmoscope (K932503) |
| | Heine Beta 200S (Device Listed by Heine USA, Ltd.,<br>establishment registration number: 1054443) |
510(k) Summary
### Device Description:
All Kirchner & Wilhelm ophthalmoscopes are battery powered. The Piccolight E50 and Eurolight E10 and E30 are single aperture ophthalmoscopes while the Piccolight E56 and Eurolight E36 have six apertures each. The Piccolight and Eurolight series are different in the handles, with Piccolight handles made of PA 6 GF 30% while Eurolight handles are made of metal. The Piccolight E50 and Eurolight E10 heads are same as the Eurolight E30 head except for the locking system. Similarly, but for the locking system, the Piccolight E56 and Eurolight E36 heads are the same.
l
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image is a logo for a company called "KaWe Medizintechnik". The logo is a square with the company name in bold, white letters at the bottom. The top of the square has the word "MEDIZINTECHNIK" in smaller letters. The background of the square is black.
## Comparison with Predicate Device:
| KIRCHNER & WILHELM | |
|--------------------|--|
| | |
| | Piccolight® E50 | Riester ophthalmoscopes Pendiza<br>Scope® (K925757) |
|----------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------|
| Intended use | An ophthalmoscope is intended to<br>be used to examine the cornea,<br>aqueous, lens, vitreous and retina<br>of the eye. | Same |
| Method of<br>operation | Used to examine the retina by an<br>examiner in a specific distance to<br>the eye. | Same |
| Exposure<br>parameters | Emission of 2.5 V vacuum bulb | Emission of 2.7 V vacuum bulb |
| data collection<br>and/or display<br>systems | Dioptre of used lens in steps:<br>-20, -15, -10, -8, -6, -4,-3, -2, -1,<br>0, 1, 2, 3, 4, 6, 8, 10, 15, 20 | Same |
| Flammability of<br>materials | Fibre-glass reinforced plastic<br>Polyamide 6 GF30C | Same |
| maximum<br>temperature of<br>parts of the<br>device held by<br>the operator or<br>accessible to<br>the patient | Ambient temperature<br>Metal parts around the bulb:<br>Approx. max. 50°C | Same |
| brightness<br>controls | No | No |
| Supply voltage | 2.5 V | 2.7 V |
| Power supply | Battery powered | Same |
| Aperture | One aperture (large circle) | four aperture (large circle, Small<br>circle, semi-circle, large circle<br>with fixing cross) |
All main aspects regarding the safety and effectiveness are comparable. The main difference is the difference in the number of apertures and that is not a significant difference.
| | Piccolight® E56 | Riester ophthalmoscope ri- mini® (K932503) |
|------------------------|-------------------------------------------------------------------------------------------------------------------------|--------------------------------------------|
| Intended use | An ophthalmoscope is intended to<br>be used to examine the cornea,<br>aqueous, lens, vitreous and retina<br>of the eye. | same |
| Method of<br>operation | Used to examine the retina by an<br>examiner in a specific distance to<br>the eye. | Same |
{2}------------------------------------------------
| Exposure<br>parameters | Emission of 2.5 V halogen bulb | Emission of 2.5 V halogen bulb | Image: KaWe logo |
|----------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------|------------------|
| data collection<br>and/or display<br>systems | Dioptre of used lens in steps:<br>-20, -15, -10, -8, -6, -4,-3, -2, -1,<br>0, 1, 2, 3, 4, 6, 8, 10, 15, 20 | Same | |
| Flammability of<br>materials | Fibre-glass reinforced plastic<br>Polyamide 6 GF30C | Same | |
| maximum<br>temperature of<br>parts of the<br>device held by<br>the operator or<br>accessible to<br>the patient | Ambient temperature<br>Metal parts around the bulb:<br>Approx. max. 50°C | Same | |
| brightness<br>controls | No | No | |
| Supply voltage | 2.5 V | 2.5 V | |
| Power supply | Battery powered | Same | |
| Aperture | six aperture (slit diaphragm, large<br>circle, small circle, semi-circle,<br>red-free (green), large circle with<br>fixing cross)<br>Image: aperture options | four aperture (large circle, Small<br>circle, semi-circle, large circle<br>with fixing cross; additional red-<br>free (green)) | |
| | or<br>Image: aperture options | | |
All main aspects regarding the safety and effectiveness are comparable. The main difference is the difference in the number of apertures with one more aperture being there in Piccolight. The additional slit diaphragm is used to differentiate the level differences (e.g, in the case of tumors or papilloedema). This has no effect on the security of the subject device as compared to the predicate.
| | EUROLIGHT® E10<br>EUROLIGHT® E30 | Riester ophthalmoscope UNI®<br>II (K925756) |
|-----------------------------------|-------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------|
| Intended use | An ophthalmoscope is intended to<br>be used to examine the cornea,<br>aqueous, lens, vitreous and retina<br>of the eye. | Same |
| Method of<br>operation | Used to examine the retina by an<br>examiner in a specific distance to<br>the eye. | Same |
| Exposure<br>parameters | Emission of 2.5 V vacuum bulb | Emission of 2.7 V vacuum bulb,<br>2.5 V halogen bulb or 3.5 xenon<br>bulb |
| data collection<br>and/or display | Dioptre of used lens in steps:<br>-20, -15, -10, -8, -6, -4, -3, -2, -1 | Same |
and and the state
{3}------------------------------------------------
| systems | 0, 1, 2, 3, 4, 6, 8, 10, 15, 20 | | Image: KaWe logo |
|----------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------|-----------------------------|------------------|
| Flammability of<br>materials | Fibre-glass reinforced plastic<br>Polyamide 6 GF30C | Metal housing | |
| maximum<br>temperature of<br>parts of the<br>device held by<br>the operator or<br>accessible to<br>the patient | Ambient temperature<br>Metal parts around the bulb:<br>Approx. max. 50°C | Same | |
| brightness<br>controls | Various | Various | |
| Supply voltage | 2.5 V | 2,5 V | |
| Power supply | Battery powered | Same | |
| Aperture | one aperture (large circle) | one aperture (large circle) | |
All main aspects regarding the safety and effectiveness are comparable. The UNI II can also be used with halogen and xenon light. Both are brighter than light from vacuum bulb. Therefore the optical radiation exposure for the eye during the examination is higher than by using a vacuum bulb. The different housing materials are not relevant for the safety of the instrument. The temperature which gets generated during examination is not able to inflame the used materials.
| | EUROLIGHT® E36 | HEINE BETA 200 S® ophthalmoscope |
|----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------|
| Intended use | An ophthalmoscope is intended to be used to examine the cornea, aqueous, lens, vitreous and retina of the eye. | Same |
| Method of operation | Used to examine the retina by an examiner in a specific distance to the eye. | Same |
| Exposure parameters | Emission of 2.5 V halogen bulb | Emission of 2.5 V or 3.5 V xenon halogen bulb |
| data collection and/or display systems | Dioptre of used lens in steps: -20, -15, -10, -8, -6, -4,-3, -2, -1, 0, 1, 2, 3, 4, 6, 8, 10, 15, 20 | Dioptre of used lens in steps: + in 1D step 1-10, 15, 20, 40<br>- in 1D step 1-10, 15, 20, 25, 35 |
| Flammability of materials | Fibre-glass reinforced plastic Polyamide 6 GF30C | Polycarbonate |
| maximum temperature of parts of the device held by the operator or accessible to the patient | Ambient temperature<br>Metal parts around the bulb: Approx. max. 50°C | Same |
| brightness | Various | Various |
{4}------------------------------------------------
| controls | | | |
|----------------|-------------------------------------------------------------------------|-------------------------------------------------------------------------|--------------------------------------------------------------------------------|
| Supply voltage | 2.5 V | 2.5 V or 3.5 V | |
| Power supply | Battery powered | Same | Image: KaWe logo<br>KIRCHNER & WILHELL<br>GmbH + Co<br>Medizintechnik, Germany |
| Aperture | six aperture<br>Image: aperture settings or<br>Image: aperture settings | six aperture<br>Image: aperture settings or<br>Image: aperture settings | |
All main aspects regarding the safety and effectiveness are comparable. The different housing materials are not relevant for the safety of the instrument.
#### Intended Use:
An ophthalmoscope is intended to be used to examine the cornea, aqueous, lens, vitreous and retina of the eye.
#### Non-Clinical Testing:
The ophthalmoscopes conform to ISO 10942; IEC 60601-1, and IEC 60601-1-2.
#### Clinical Testing:
Not applicable
#### Conclusion:
The ophthalmoscopes referred to in this 510(k) submission are substantially equivalent to the predicates and raise no issues of safety and effectiveness.
{5}------------------------------------------------
Public Health Service
Image /page/5/Picture/2 description: The image shows the logo for the Department of Health & Human Services (HHS). The logo features a stylized eagle with three tail feathers, representing the three branches of government. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" are arranged in a circular pattern around the eagle.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
NOV - 5 2007
Kirchner & Wilhelm GmbH & CO. KG c/o Natalya Valerio mdi Consultants Inc. 55 Northern Blvd., Suite 200 Great Neck, NY 11021
Re: K070270
Trade/Device Name: Piccolight E50 & E56 and Eurolight E10, E30 & E36 Regulation Number: 21 CFR 886.1750 Regulation Name: Ophthalmoscope Regulatory Class: Class II Product Code: HLJ Dated: October 18, 2007 Received: October 26, 2007
Dear Ms. Valerio:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
{6}------------------------------------------------
This letter will allow you to begin marketing your device as described in your Section 510(k) Premarket notification. The FDA finding of substantial equivalence of your device to a legally promative hotification " results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, please contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Mcdical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-(Woulear Do not responsible other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
M.B. Eglehus, MD
Malvina B. Eydelman, M.D. Director Division of Ophthalmic and Ear, Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
# INDICATIONS FOR USE
Page _ 1 _ of _ 1
K070270
510(k) Number (if known): Not Assigned as of this time
Device Name: Piccolight® E50, Piccolight® E56, Eurolight® E10, Eurolight® E30, Eurolight® E36 Ophthalmascopes
#### Indications for Use:
An ophthalmoscope is intended to be used to examine the cornea, aqueous, lens, vitreous and retina of the eye.
Danilu 10/31/2007
(Division Sion-Off) Division of Ophthalmic Ear, Nose and Throat 510(k) Number
Prescription Use X (Per 21 CFR 801 Subpart D)
OR
Over-The Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.