← Product Code [JAK](/productcode/JAK) · K063324

# PET VCAR (K063324)

_GE Healthcare · JAK · Mar 23, 2007 · Radiology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K063324

## Device Facts

- **Applicant:** GE Healthcare
- **Product Code:** [JAK](/productcode/JAK.md)
- **Decision Date:** Mar 23, 2007
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 892.1750
- **Device Class:** Class 2
- **Review Panel:** Radiology
- **Attributes:** Software as a Medical Device, 3rd-Party Reviewed

## Indications for Use

PET VCAR (Volume Computer Assisted Reading) is a PET/CT software package which can be used by the clinician to assist in diagnosis, staging, treatment planning and monitoring treatment response. The PET VCAR automatically highlights and bookmarks PET defined regions of interest based on user-defined threshold settings. The software can be used for visualization and analytical monitoring of disease progression or response to treatment or therapy using multiexam comparison. The software is designed to measure Standard Uptake Value (SUV) and volume for any PET defined metabolic activity. The software automatically propagates bookmarks from one time point to another for the purpose of improving analysis and workflow. PET VCAR offers a tool called Interactive Data Analysis (IDA) spreadsheet that compiles and manages all the analytical information in an organized and interactive design. The IDA is synchronized with the image display layouts offering quick measurement / image visual validation. PET VCAR's workflow is designed to allow clinicians to make informed follow-up decisions in an efficient manner. PET VCAR does not provide or claim any automatic detection or automatic diagnosis of abnormal anatomy, structure or function.

## Device Story

PET VCAR is a PET/CT software package for clinical use in diagnosis, staging, treatment planning, and monitoring. Input: PET/CT image data (DICOM). Operation: Software highlights and bookmarks PET-defined regions of interest based on user-defined thresholds; calculates Standard Uptake Value (SUV) and volume; propagates bookmarks across time points for longitudinal analysis. Output: Interactive Data Analysis (IDA) spreadsheet and synchronized image displays. Context: Used by clinicians on Advantage Windows Workstations; facilitates follow-up decisions by organizing analytical data. Benefits: Improved workflow efficiency and standardized measurement of metabolic activity. Does not perform automatic detection or diagnosis.

## Clinical Evidence

Bench testing only. Verification and validation processes confirmed performance to specifications and user requirements. No clinical data provided.

## Technological Characteristics

Software-based PET/CT analysis package. Compatible with Advantage Windows Workstation 4.4 or higher. Supports DICOM standard for data import/export (Secondary Capture, Structured Report). Formats supported: HTML, XML, PDF, CSV. No hardware components.

## Regulatory Identification

A computed tomography x-ray system is a diagnostic x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.

## Predicate Devices

- Volume Viewer Plus ([K041521](/device/K041521.md))
- Advanced Lung Analysis II ([K042694](/device/K042694.md))
- Advantage Fusion ([K983256](/device/K983256.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

K063324/

GE Healthcare

# PET VCAR

MAR 2 3 2007

# 510 (k) Summary of Safety and Effectiveness

This 510(k) summary of safety and effectiveness information is submitted in accordance with the requirements of 21 CFR Part 807.87 (h)

# 1. Identification of submitter: Larry A. Kroger, Ph.D. Senior Regulatory Program Manager 3000 N. Grandview Blvd Waukesha, 53188 USA Telephone: 262-544-3894 Fax: 262-548-4768 Date Prepared: August 23, 2006

## 2. Identification of Product:

| Device name                  | PET VCAR.                                                                                                                 |
|------------------------------|---------------------------------------------------------------------------------------------------------------------------|
| Classification name          | Computed tomography x-ray system per<br>21 CFR 892.1750<br><br>Emission computed tomography system<br>per 21 CFR 892.1200 |
| Manufacturer/<br>Distributor | General Electric Medical Systems SAS<br>283, Rue de la Minière<br>78533 BUC Cedex France                                  |

# 3. Marketed Devices

PET VCAR is substantially equivalent to the devices listed below:

| Model:        | Volume Viewer Plus               |
|---------------|----------------------------------|
| Manufacturer: | General Electric Medical Systems |
| 510 (k):      | K041521                          |
| Model:        | Advanced Lung Analysis II        |
| Manufacturer: | General Electric Medical Systems |
| 510 (k):      | K042694                          |
| Model:        | Advantage Fusion                 |
| Manufacturer: | General Electric Medical Systems |
| 510 (k):      | K983256                          |

{1}------------------------------------------------

Image /page/1/Picture/1 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'G' and 'E' intertwined within a circle. The letters are stylized with curved lines and serifs, and the circle has decorative swirls around its perimeter.

## 4. Device Description :

PET VCAR (Volume Computer Assisted Reading) is a PET/CT software package which can be used by the clinician to assist in diagnosis, staging, treatment planning and monitoring treatment response. The PET VCAR automatically highlights and bookmarks PET defined regions of interest based on user-defined threshold settings. The software can be used for visualization and analytical monitoring of disease progression or response to treatment or therapy using multiexam comparison. The software is designed to measure Standard Uptake Value (SUV) and volume for any PET defined metabolic activity. The software automatically propagates bookmarks from one time point to another for the purpose of improving analysis and workflow. PET VCAR offers a tool called Interactive Data Analysis (IDA) spreadsheet that compiles and manages all the analytical information in an organized and interactive design. The IDA is synchronized with the image display layouts offering quick measurement / image visual validation. PET VCAR's workflow is designed to allow clinicians to make informed follow-up decisions in an efficient manner. PET VCAR does not provide or claim any automatic detection or automatic diagnosis of abnormal anatomy, structure or function.

The GE PET VCAR has to ensure relations with the following external systems:

#### Data Import

Image, exam and patient data can be imported in accordance with the DICOM Standard.

#### Data Export

Finding, exam and patient information can be exported in the Secondary Capture format of the DICOM standard that enables its storage on PACS systems.

Finding, exam and patient information can be exported in the Structured Report format of the DICOM standard that enables its display with DICOM SR compatible viewers.

Finding, exam and patient information can be exported in standard formats like HTML, XML, PDF, CSV, that enables its display with viewers compatible with the mentioned formats.

#### Configuration Requirements

PET VCAR is compatible with Advantage Windows Workstation™ 4.4 or higher

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'G' and 'E' intertwined within a circle. The logo is black and white.

### 5. Indications for Use

PET VCAR (Volume Computer Assisted Reading) is a PET/CT software package which can be used by the clinician to assist in diagnosis, staging, treatment planning and monitoring treatment response. The PET VCAR automatically highlights and bookmarks PET defined regions of interest based on user-defined threshold settings. The software can be used for visualization and analytical monitoring of disease progression or response to treatment or therapy using multiexam comparison. The software is designed to measure Standard Uptake Value (SUV) and volume for any PET defined metabolic activity. The software automatically propagates bookmarks from one time point to another for the purpose of improving analysis and workflow. PET VCAR offers a tool called Interactive Data Analysis (IDA) spreadsheet that compiles and manages all the analytical information in an organized and interactive design. The IDA is synchronized with the image display layouts offering quick measurement / image visual validation. PET VCAR's workflow is designed to allow clinicians to make informed follow-up decisions in an efficient manner. PET VCAR does not provide or claim any automatic detection or automatic diagnosis of abnormal anatomy, structure or function.

#### 6. Comparison with Predicate Device

The functional features of PET VCAR software package are substantially equivalent to that of the following devices:

| Device Name                | FDA Clearance Number |
|----------------------------|----------------------|
| Volume Viewer Plus         | K041521              |
| Advantage Lung Analysis II | K042694              |
| Advantage Fusion           | K983256              |

# 7. Adverse Effects on Health

The potential hazards are identified in a risk management summary (hazard analysis) and are controlled by:

- . Software Development. Validation and Verification Process to ensure performance to specifications, Federal Regulations and user requirements.
- Adherence to industry and international standards. .

#### 8. Conclusions

The PET VCAR does not result in any new potential safety risks and performs as well as devices currently on the market. GE considers features of the PET VCAR to be equivalent to those of Volume Viewer Plus (K041521), Advanced Lung Analysis II (K042694) and Advantage Fusion (K983256).

{3}------------------------------------------------

Image /page/3/Picture/0 description: The image shows a circular seal with text around the perimeter and a stylized graphic in the center. The text reads "DEPARTMENT OF HEALTH & HUMAN SERVICES USA". The central graphic consists of three curved lines that resemble a stylized human figure.

Food and Drug Administration 9200 Corporate Blvd. Rockville MD 20850

GE Healthcare % Mr. Neil E. Devine, Jr. Sr. Staff Engineer - Medical Devices Intertek Testing Services NA, Inc. 2307 East Aurora Rd., Unit B7 TWINSBURG OH 44087

MAR 2 3 2007

Re: K063324

Trade/Device Name: PET VCAR Regulation Number: 21 CFR 892.1750 Regulation Name: Computed tomography x-ray system Regulation Number: 21 CFR 892.1200 Regulation Name: Emission computed tomography system Regulatory Class: II Product Code: JAK and KPS Dated: March 7, 2007 Received: March 8, 2007

Dear Mr. Devine:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Image /page/3/Picture/10 description: The image is a black and white circular logo. The logo has the letters "FDA" in the center, with the word "Centennial" underneath. Above the letters "FDA" are the numbers "1906-1906". The logo is surrounded by a dotted border.

Protecting and Promoting Public Health

{4}------------------------------------------------

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:

| 21 CFR 876.xxx | (Gastroenterology/Renal/Urology | 240-276-0115 |
|----------------|---------------------------------|--------------|
| 21 CFR 884.xxx | (Obstetrics/Gynecology)         | 240-276-0115 |
| 21 CFR 894.xxx | (Radiology)                     | 240-276-0120 |
| Other          |                                 | 240-276-0100 |

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150

or at its Internet address http://www.fda.gov/cdrl/industry/support/index.html.

Sincerely vours.

Nancy C. Hogdon

Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

# Indications for Use

510(k) Number (if known): _长0633 at

Device Name: PET VCAR

Indications for Use:

PET VCAR (Volume Computer Assisted Reading) is a PET/CT software package which can be used by the clinician to assist in diagnosis, staging, treatment planning and monitoring treatment response. The PET VCAR automatically highlights and bookmarks PET defined regions of interest based on user-defined threshold settings. The software can be used for visualization and analytical monitoring of disease progression or response to treatment or therapy using multiexam comparison. The software is designed to measure Standard Uptake Value (SUV) and volume for any PET defined metabolic activity. The software automatically propagates bookmarks from one time point to another for the purpose of improving analysis and workflow. PET VCAR offers a tool called Interactive Data Analysis (IDA) spreadsheet that compiles and manages all the analytical information in an organized and interactive design. The IDA is synchronized with the image display layouts offering quick measurement / image visual validation. PET VCAR's workflow is designed to allow clinicians to make informed follow-up decisions in an efficient manner. PET VCAR does not provide or claim any automatic detection or automatic diagnosis of abnormal anatomy, structure or function.

Prescription Use Over-The-Counter Use X ANDIOR (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Page __ 1_ of __ 1

David A. Sygman

(Division Sign-Off) Division of Reproductive, A and Radiological Devices 510/k) Number

---

**Source:** [https://fda-staging.innolitics.com/device/K063324](https://fda-staging.innolitics.com/device/K063324)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
