K063113 · Ep Medsystems · DQK · Oct 27, 2006 · Cardiovascular
Device Facts
Record ID
K063113
Device Name
EP-WORKMATE
Applicant
Ep Medsystems
Product Code
DQK · Cardiovascular
Decision Date
Oct 27, 2006
Decision
SESE
Submission Type
Special
Regulation
21 CFR 870.1425
Device Class
Class 2
Indications for Use
The EP-WorkMate® with an EP-3 (K935590) or EP-4 (K041442) stimulator is intended to be used for diagnostic electrical stimulation of the heart for the purpose of refractory measurements, initiation and termination of tachy-arrhythmias measurements of electrical conduction. The addition of NurseMate™ does not change intended use of the EP-WorkMate®.
Device Story
NurseMate™ is an optional PC workstation for the EP-WorkMate® system used in cardiac electrophysiology (EP) labs. It functions as a client-server extension, allowing clinical staff (nurses/technicians) to perform real-time patient charting, physiologic monitoring (HR, BP), and data analysis at a separate station, reducing congestion at the primary physician-controlled EP-WorkMate® station. It receives intracardiac ECG waveforms and physiologic data from the EP-WorkMate® amplifier/signal conditioning unit via TCP/IP and Packet Driver protocols. The device displays waveforms and tabular data on a touchscreen monitor; it allows entry of event titles, medications, and comments, which are stored in the patient file on the EP-WorkMate®. It can trigger start/stop recording on the primary system but cannot modify or delete clinical data. It does not control the cardiac stimulator. The system benefits the patient by facilitating efficient clinical documentation and monitoring during diagnostic EP procedures.
Clinical Evidence
No clinical data provided. Bench testing only.
Technological Characteristics
PC-based workstation; Pentium® microprocessor; Microsoft Windows® OS; touch screen LCD monitor; mouse/keyboard; equipment cart. Connectivity via CAT 5 cabling, RJ-45 connectors, TCP/IP, and Packet Driver protocols. Software developed in Microsoft Visual C++ 6.0. Standalone networked client-server architecture.
Indications for Use
Indicated for use during clinical electrophysiology procedures for patients undergoing cardiac EP studies to diagnose arrhythmias.
Regulatory Classification
Identification
A programmable diagnostic computer is a device that can be programmed to compute various physiologic or blood flow parameters based on the output from one or more electrodes, transducers, or measuring devices; this device includes any associated commercially supplied programs.
{0}------------------------------------------------
K063113
Image /page/0/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized, abstract graphic on the left, resembling a scribble or a stylized representation of a medical symbol. To the right of the graphic is the text "EPMedSystems" in a serif font. The text is in all caps except for the "d" and "s" in "MedSystems", which are in lowercase.
# 510(k) Summary
### Summary preparation date: 10/10/06
#### 1.0 Device Trade Name
| Device Trade Name | Device Classification |
|-------------------|-------------------------------------|
| EP-WorkMate® | Programmable Diagnostic<br>Computer |
#### 2.0 Establishment Address and Registration
### EP MedSystems Inc.
Cooper Run Executive Park 575 Route 73 North, Building D West Berlin, NJ 08091-9293 USA
Larry Picciano Telephone: 856-753-8533 Fax: 856-753-8544 E-mail: Ipicciano@epmedsystems.com
US Food and Drug Administration Establishment Registration No.. 2248049
#### 3.0 Device Classification
Programmable diagnostic computers have been classified as Class II, 74 DQK. No performance standards have been established under CFR 21 Part 870.1425 or Section 514 of the Food, Drug, and Cosmetic Act for programmable diagnostic computers.
#### 4.0 *Predicate Devices / Technology
| Product Description | 510 (k) No. | Date |
|------------------------------------------------------------------------|-------------|----------|
| EP-WorkMate® | K994011 | 03/23/00 |
| * This application describes a modification to the EP-WorkMate® called | | |
NurseMate™
#### 5.0 Labeling and Intended Use
The following labeling is contained within Appendix 4.
- 5.1 Proposed Product Labeling
- 5.2 Proposed Marketing Literature
- 5.3 Proposed Instructions for Use Manual
This document is the property of EPMedSystems. Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published to others, in whole or in part, without express written consent of EPMedSystems' executive management.
{1}------------------------------------------------
063113 D 216
Image /page/1/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized, abstract symbol on the left, resembling a series of curved lines or a coil. To the right of the symbol is the text "EPMedSystems" in a serif font. The logo is simple and professional in appearance.
#### 5.4 Intended Use
The EP-WorkMate® with an EP-3 (K935590) or EP-4 (K041442) stimulator is intended to be used for diagnostic electrical stimulation of the heart for the purpose of refractory measurements, initiation and termination of tachy-arrhythmias measurements of electrical conduction. The addition of NurseMate™ does not change intended use of the EP-WorkMate®.
#### Indications for Use 6.0
### Indications for Use Statement
EP-WorkMate® is indicated for use during clinical electrophysiology procedures. The addition of NurseMate™ does not change the indications for use.
#### 7.0 Device Description
- Background description of EP-WorkMate®: Cardiac EP studies are 7.1 diagnostic tests that enable physicians to look at electrical signals from within the heart in detail to determine if an abnormality (arrhythmia) exists. The cardiac EP laboratory is typically staffed with one or more physicians, nurses, and technologists thus making the lab a busy and sometimes crowded workspace. A physician directs the EP study and the operation of the EP-WorkMate® system; some physicians operate the system, others direct a member of the clinical staff on the system operation. The EP-WorkMate® system is illustrated in Figure 1. Under the direction of a physician, the cardiac stimulator delivers diagnostic stimuli to the heart through the EP catheter(s). The heart's electrical response to the diagnostic signals is returned through the catheter(s) to the amplifier/signal conditioning unit. The amplified and conditioned signals are displayed as waveforms and tabular EP data on the EP-WorkMate® real-time display monitor for diagnosis by the physician. A physician may also choose to record/store the signals using the EP-WorkMate®.
Image /page/1/Figure/9 description: This image shows a diagram of a medical monitoring system. The diagram includes a patient, a doctor, and several medical devices. The patient is connected to a 12 Lead ECG, catheters, and a pressure sensor. The data from these devices is sent to a junction box, then to an Amp/SCU, and finally to a WorkMate. The WorkMate is connected to a real-time monitor, a review monitor, a stimulator, and a printer. The doctor is shown standing next to the WorkMate.
This document is the property of EPMedSystems. Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published or disclosed to others, in whole or in part, without express written consent of EPMedSystems' executive management.
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows the logo for EPMedSystems. The logo consists of a stylized graphic to the left of the company name. The graphic is a black, abstract design. The company name, "EPMedSystems," is written in a serif font.
## Figure 1: EP-WorkMate® System Block Diagram
- 7.2 General description of NurseMate™: This application describes a modification to the EP-WorkMate® computer that will be offered as an option to customers under the name NurseMate™. NurseMate™ is a PC (Personal Computer) workstation that when connected to the EP-WorkMate® system can be used for real-time patient charting, physiologic monitoring, and data analysis during electrophysiology (EP) studies. The interconnection of NurseMate™ to EP-WorkMate® is illustrated in Figure 2. Expanding the EP-WorkMate® system with the optional NurseMate™ creates an additional workstation for a member of the EP team such as a The additional workstation reduces crowding at the main EPnurse. WorkMate® station and eases workflow congestion in the busy cardiac EP laboratory. Using NurseMate™ an EP lab staff member can perform patient charting (e.g., event titles, medications, comments) and monitor physiologic data including heart rate (HR) and blood pressure (BP) on their own display separate from the physician who is controlling the EP using EP-WorkMate® workstation. study Figure 3 illustrates NurseMate's™ graphical user interface (GUI) displaying HR and BP.
Image /page/2/Figure/4 description: This image shows a diagram of a medical system. The system includes components such as Amp/SCU, EP-WorkMate Computer, NurseMate Computer, Review Monitor, RealTime Monitor, and NurseMate LCD Touchscreen Monitor. The diagram also shows the connections between these components, including Amp/SCU Communication Line and EP-WorkMate/NurseMate Communication Line. The diagram also shows the people who use the system, including the patient, doctor, and nurse.
Figure 2: EP-WorkMate® with NurseMate™ Block Diagram
- 7.3 NurseMate™ software description: The NurseMate™ for EP-WorkMate® software installed on NurseMate™ is simply a modified version of the EP-WorkMate® application software. The EP-WorkMate® software was modified using the same Microsoft Visual C++ 6.0 Integrated Development Environment (with Visual Studio Service Pack
This document is the property of EPMedSystems. Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published or disclosed to others, in whole or in part, without express written consent of EPMedSystems' executive management.
Page 3 of 6
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized graphic to the left of the company name. The graphic is a black, abstract shape that resembles a coil or swirl. The text "EPMedSystems" is in a serif font and is also black.
6.0) within which it was developed. The NurseMate™ for EP-WorkMate® program code is taken directly from the WorkMate's® C++ program code; The important hence, the software applications are highly similar. exception between EP-WorkMate® and NurseMate™ is that the EP-WorkMate® controls the cardiac stimulator while NurseMate™ does not. A list comprising a functional software comparison between EP-WorkMate® and NurseMate™ is presented in Table 1.
Image /page/3/Figure/3 description: The image shows a medical monitor displaying various waveforms and data. On the left side, there are multiple ECG leads labeled I(S), II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, and V6, each with corresponding numerical values. The right side displays waveforms for II, HIS d, HRA, RVA, and HIS m, along with numerical values and a "Physiologic Window" indicating HR=133 bpm, BP=559/-89/127 mmHg, and other parameters in DEMO MODE.
Figure 3: NurseMate™ Graphical User Interface with Physiologic Data
- 7.4 NurseMate™ NurseMate™ hardware is hardware description: designed and built using similar PC technology employed in the EP-WorkMate®. NurseMate™ comprises a: PC, touch screen LCD monitor, Central Processing Unit (CPU), mouse, keyboard, and an equipment cart. The CPU is an off-the-shelf Pentium® microprocessor based personal computer running Microsoft Windows® Operating System (OS), with on board Random Access Memory (RAM), a Hard Disk Drive (HDD), a Read/Writable (R/W) Compact Disk (CD), multiple Universal Serial Bus
This document is the property of EPMedSystems. Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published to others, in whole or in part, without express written consent of EPMedSystems' executive management.
Page 4 of 6
{4}------------------------------------------------
K063113
p5/6
Image /page/4/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized, abstract symbol resembling a coil or swirl on the left, followed by the text "EPMedSystems" in a bold, sans-serif font. The text is closely aligned with the symbol, creating a unified brand identity.
(USB) ports, and a Network Interface Controller (NIC). The NurseMate™ station has a smaller, more movable, form factor than EP-WorkMate®; it has a single display monitor and a smaller footprint cart with castors. Figure 4 illustrates the NurseMate TM station form factor.
Image /page/4/Picture/3 description: The image shows a medical workstation with a chair. The workstation has a monitor and a keyboard on top of a rolling stand. The chair is a stool with a backrest and a footrest, also on wheels. The workstation and chair appear to be designed for use in a medical setting, such as a doctor's office or hospital.
Figure 4: NurseMate™ Work Station
- 7.5 EP-WorkMate® with NurseMate™ connection: To use NurseMate™ as intended, it must be connected to the EP-WorkMate® through two basic electronic interconnections.
- 7.5.1 PC-to-PC connection: The first interconnection between the two computers illustrated in Figure 5 is required for the client-server The EP-WorkMate® acts as the server and the operation. NurseMate™ acts as the client via handshaking signals. The client is passive except in that NurseMate™ can issue commands to the WorkMate® to start/stop data recording. The hardware interconnection between the computers is comprised of off-theshelf category five (CAT 5) network cabling; the connections are terminated with standard data communication connectors (RJ-45). LAN connectivity is established using standard networking software protocol, Telecommunications Protocol/Internet Protocol (TCP/IP).
- 7.5.2 PC-to-Amp/SCU connection: The second interconnection between the NurseMate™ computer and the EP-WorkMate®
This document is the property of EPMedSystems. Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published or disclosed to others, in whole or in part, without express written consent of EPMedSystems' executive management.
Page 5 of 6
020005
{5}------------------------------------------------
Image /page/5/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized, abstract graphic to the left of the text "EPMedSystems". The graphic is a black, swirling shape, and the text is in a bold, serif font, also in black.
amplifier uses the same hardware as a LAN connection. Communication is accomplished using a common software protocol known as Packet Driver which is similar to TCP/IP. This connection enables the NurseMate™ user to independently configure and view real time patient EP waveforms from the amplifier (Amp/SCU) during an EP study.
Image /page/5/Figure/3 description: This image shows a network diagram of a medical system. The system includes components such as Amp/SCU, EP-WorkMate Computer, NurseMate Computer, Review Monitor, RealTime Monitor, and NurseMate LCD Touchscreen Monitor. The diagram also indicates communication protocols such as Amp/SCU Communication (Packet Driver) and EP-WorkMate/NurseMate Communication (TCP/IP). The diagram shows the connections between the different components and the flow of data within the system.
# Figure 5: EP-WorkMate® with NurseMate™ Interconnection Diagram
Data is received by the NurseMate™ from the EP-WorkMate® via the two interconnections. The NurseMate™ user can only view clinical data (e.g., intracardiac ECG waveforms); this data can not be modified or deleted. NurseMate™ users may independently enter tabular data regarding the case (e.g., event identification, medication, and nurses' or doctors' comments). Tabular data entries are stored as part of the patient file on the EP-WorkMate® as if the data were entered on the EP-WorkMate®. NurseMate™ controls only start/stop recording in the EP-WorkMate®; it does not control any aspect of other devices interconnected with the EP-WorkMate®.
### End of document
This document is the property of EPMedSystems, Its' entire content is considered proprietary and confidential by EP MedSystems. This document may not be copied, reproduced, published or disclosed to others, in whole or in part, without express written consent of EPMedSystems' executive management.
Page 6 of 6
{6}------------------------------------------------
Public Health Service
Image /page/6/Picture/2 description: The image shows the seal of the Department of Health & Human Services (HHS). The seal features a stylized eagle with its wings spread, symbolizing protection and service. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" are arranged in a circular pattern around the eagle, indicating the department's name and national affiliation.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
OCT 2 7 2006
EPMed Systems c/o Larry Picciano Directory of Regulatory Affairs Cooper Run Executive Park 575Route 73 N. Bldg. D West Berlin, NY 08091
Re: K063113
Trade/Device Name: NurseMate™ Regulation Number: 21 CFR 870.1425 Regulation Name: Programmable Diagnostic Computer Regulatory Class: Class II Product Code: DQK Dated: October 10, 2006 Received: October 11, 2006
Dear Mr. Picciano:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{7}------------------------------------------------
Page 2 - Mr. Larry Picciano
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
Bzimmermaſch
Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{8}------------------------------------------------
K063113
Image /page/8/Picture/1 description: The image shows the logo for EPMedSystems. The logo consists of a stylized graphic to the left of the company name. The graphic is a black, abstract design. The text "EPMedSystems" is in a serif font, with the letters appearing in black.
Cooper Run Executive Park 575 Route 73 North, Building D West Berlin, New Jersey 08091 (856)753-8533 Tel: Fax: (856)753-8544
# Indications for Use
Device Name: NurseMate™
Indications for Use: NurseMateTM is indicated for use during clinical electrophysiology procedures.
AND/OR Over-The-Counter Use Prescription Use V (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Blhmmmmmm
(Division Sign-Off)
Division of Cardloyascular Devices 510(k) Number
Page 1 of 1
File: Indcations for Use FDA Response 102406.doc
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.