COMPRESS SEGMENTAL FEMORAL REPLACEMENT SYSTEM (SHORT SPINDLE AND ANCHOR PLUG)
K062998 · Biomet Manufacturing Corp · KWA · Jan 19, 2007 · Orthopedic
Device Facts
Record ID
K062998
Device Name
COMPRESS SEGMENTAL FEMORAL REPLACEMENT SYSTEM (SHORT SPINDLE AND ANCHOR PLUG)
Applicant
Biomet Manufacturing Corp
Product Code
KWA · Orthopedic
Decision Date
Jan 19, 2007
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3330
Device Class
Class 3
Attributes
Therapeutic
Indications for Use
1. Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. 2. Tumor resections. 3. Revision of previously failed total joint arthroplasty. 4. Trauma. The Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) components are intended for uncemented use only.
Device Story
Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) is a prosthetic implant system designed for femoral reconstruction. It utilizes a spring-enhanced, stress-sharing mechanism to generate compressive force on host bone, intended to prevent bone atrophy and promote bone growth. The system comprises an Anchor Plug, Spindle, and Taper Adapter. It is used in conjunction with existing hip or knee joint components. The device is implanted by a surgeon in a clinical setting. By maintaining bone health through stress-sharing, the device aims to improve long-term fixation and stability in patients undergoing complex orthopedic revisions or tumor resections.
Clinical Evidence
No clinical data provided as a basis for substantial equivalence. Substantial equivalence is supported by non-clinical mechanical testing.
Technological Characteristics
Spring-enhanced, stress-sharing femoral implant system. Components: Anchor Plug, Spindle, Taper Adapter. Materials conform to the same standards as the predicate device. Intended for uncemented use only. Mechanical design generates compressive stress on host bone.
Indications for Use
Indicated for patients requiring revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement; tumor resections; revision of failed total joint arthroplasty; or trauma. Intended for uncemented use.
Regulatory Classification
Identification
A hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis is a two-part device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral and an acetabular component, both made of alloys, such as cobalt-chromium-molybdenum. The femoral component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027).
Predicate Devices
Compress® Segmental Femoral Replacement System (K043547)
Submission Summary (Full Text)
{0}------------------------------------------------
# 510(k) Summary
| Preparation Date: | 1/8/2007<br>JAN 19 2007 |
|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Applicant/Sponsor: | Biomet Manufacturing Corp.<br>56 East Bell Drive<br>P.O. Box 587<br>Warsaw, Indiana 46581-0587 |
| Contact Person: | Jing Xie, Ph.D.<br>Biomet Manufacturing Corp. |
| Proprietary Name: | Compress® Segmental Femoral Replacement System (Short Spindle and<br>Anchor Plug) |
| Common Name: | Segmental Femoral Stem Component |
| Classification Name: | Hip Joint, Metal/Polymer, Semi-Constrained, Cemented Prosthesis<br>(21 CFR §888.3350)<br>Knee Joint, Femorotibial, Metal/Polymer Constrained, Cemented Prosthesis<br>(21 CFR §888.3510)<br>The compatible Compress® Proximal Femoral Components, OSS® System<br>components, compatible heads, liners, shells, screws, knee femoral and<br>tibial components included in this submission have the following<br>classifications: |
| Subsequent Product Codes: | JDI, Hip Joint, Metal/Polymer, Semi-Constrained, Cemented Prosthesis<br>(21 CFR §888.3350)<br>JDL, Hip joint metal/metal semi-constrained, with a cemented acetabular<br>component, prosthesis (21 CFR §888.3320)<br>KRO, Knee joint femorotibial metal/polymer constrained cemented<br>prosthesis (21 CFR §888.3510)<br>KWA, Hip joint metal/metal semi-constrained, with an uncemented<br>acetabular component, prosthesis (21 CFR §888.3330)<br>KWY, Hip joint femoral (hemi-hip) metal/polymer cemented or<br>uncemented prosthesis (21 CFR §888.3390)<br>KWZ, Hip joint metal/polymer constrained cemented or uncemented<br>prosthesis (21 CFR §888.3310)<br>LPH, Hip joint metal/polymer/metal semi-constrained porous-coated<br>uncemented prosthesis (21 CFR §888.3358)<br>LZO, Hip joint metal/ceramic/polymer semi-constrained cemented or<br>nonporous uncemented prosthesis (21 CFR §888.3353)<br>LZY, Hip joint (hemi-hip) acetabular metal cemented prosthesis (21 CFR<br>§888.3370)<br>MEH, Hip joint metal/ceramic/polymer semi-constrained cemented or<br>nonporous uncemented prosthesis (21 CFR §888.3353) |
{1}------------------------------------------------
#### Biomet Manufacturing Corp. Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) Page 2 of 2
#### Legally Marketed Devices To Which Substantial Equivalence Is Claimed:
Compress® Segmental Femoral Replacement System - K043547 (Biomet Manufacturing Corp.)
Device Description: The Compress® Seqmental Femoral Replacement System (Short Spindle and Anchor Plug) utilizes a spring-enhanced and stress-sharing design; to generate stress on the host bone which helps prevent bone atrophy and promotes bone growth. It is intended to be used in conjunction with a knee or hip implant. The device consists of the three main components, the Anchor Plug, Spindle, and the Taper Adapter.
#### Intended Use:
Indications for Use:
- 1. Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement.
- 2. Tumor resections.
- 3. Revision of previously failed total joint arthroplasty.
- 4. Trauma.
The Compress® Seqmental Femoral Replacement System (Short Spindle and Anchor Pluq) components are intended for uncemented use only.
Summary of Technologies: The Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Pluq) utilizes the same spring-enhanced, stress-sharing design as the predicate Compress® device to generate stress on the host bone which helps prevent bone atrophy and promotes bone growth. The technological characteristics of the Compress® Segmental Replacement System (Short Spindle and Anchor Plug) is identical to the predicate device. All the dimensional specifics of these components are similar to those of the predicate device. The Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) is used in conjunction with the same hip or knee components as the predicate device. Finally, the Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) is made from the same materials conforming to the same standards as the predicate device.
Non-Clinical Testing: Successful mechanical testing on Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) indicated that the device is functional within its intended use and substantially equivalent to the predicate device in performance characteristics.
Clinical Testing: None provided as a basis for substantial equivalence.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo features the department's emblem, which consists of a stylized caduceus-like symbol with three curved lines representing the human form. The emblem is positioned to the right of the text, which reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement around the emblem.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
APR 2 3 2009
Biomet Manufacturing Corp. % Jing Xie, Ph.D. Manager, Clinical Affairs P. O. Box 587 Warsaw, Indiana 46581-0587
Re: K062998
Trade/Device Name: Compress Segmental Femoral Replacement System (Short Spindle and Anchor Plug) Regulation Number: 21 CFR 888.3330 Regulation Name: Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis Regulatory Class: III Product Code: KWA, JDL, KRO, KWZ, JDI, LZO, MEH, LPH, KWY Dated: January 12, 2007 Received: January 12, 2007
Dear Dr. Xie:
This letter corrects our substantially equivalent letter of January 19, 2007.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other
{3}------------------------------------------------
Page 2 - Jing Xie, Ph.D.
Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please contact the CDRH/Office of Surveillance and Biometrics/Division of Postmarket Surveillance at 240-276-3464. For more information regarding the reporting of adverse events, please go to http://www.fda.gov/cdrh/mdr/.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Mark N. Melkerson
Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
### Indications for Use
# 10(k) Number (if known): _____________________________________________________________________________________________________________________________________________________
### bevice Name:
Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug)
#### Indications for Use:
Indications:
- 1. Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement.
- 2. Tumor resections.
- 3. Revision of previously failed total joint arthroplasty.
- 4. Trauma.
The Compress® Segmental Femoral Replacement System (Short Spindle and Anchor Plug) components are intended for uncemented use only.
Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use NO (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Valeria Bueno
(Division S Division of Ceneral, Destorative, and Neuro... Collection Cester
**510(k) Number:** K062998.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.