DIMENSION VISTA DIGITOXIN, DIGOXIN, GENTAMICIN, N-ACETYLPROCAINAMIDE, PHENYTOIN, THEOPHYLLINE FLEX REAGENT CARTRIDGE
Device Facts
| Record ID | K062024 |
|---|---|
| Device Name | DIMENSION VISTA DIGITOXIN, DIGOXIN, GENTAMICIN, N-ACETYLPROCAINAMIDE, PHENYTOIN, THEOPHYLLINE FLEX REAGENT CARTRIDGE |
| Applicant | Dade Behring, Inc. |
| Product Code | LFM · Clinical Toxicology |
| Decision Date | Jul 28, 2006 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 862.3300 |
| Device Class | Class 2 |
Indications for Use
The DGTX method is an in vitro diagnostic test for the quantitative measurement of digitoxin in serum and plasma on the Dimension Vista™ System. Measurements of digitoxin are used in the diagnosis and treatment of digitoxin overdose and in monitoring levels of digitoxin to ensure appropriate therapy. The DIG method is an in vitro diagnostic test for the quantitative measurement of digoxin in serum and plasma on the Dimension Vista™ System. Measurements of digoxin are used in the diagnosis and treatment of digoxin overdose and in monitoring levels of digoxin to ensure appropriate therapy. The GENT method is an in vitro diagnostic test for the quantitative measurement of gentamicin, an aminoglycoside antibiotic, in human serum and plasma on the Dimension Vista™ System. Gentamicin measurements may be used in the diagnosis and treatment of gentamicin overdose and in monitoring levels of gentamicin to ensure appropriate therapy. The NAPA method is an in vitro diagnostic test for the quantitative measurement of N-acetylprocainamide in serum and plasma on the Dimension Vista™ System. N-acetylprocainamide measurements may be used in therapeutic drug monitoring to maintain adequate procainamide therapy. The PTN method is an in vitro diagnostic test for the quantitative measurement of phenytoin, (dilantin, diphenylhydantoin), an anti-epileptic drug, in human serum and plasma on the Dimension Vista™ System. Phenytoin measurements may be used in the diagnosis and treatment of phenytoin overdose and in monitoring levels of phenytoin to ensure appropriate therapy. The THEO method is an in vitro diagnostic test for the quantitative measurement of theophylline in human serum and plasma on the Dimension Vista™ System.
Device Story
The device consists of Dimension Flex reagent cartridges for Digitoxin, Digoxin, Gentamicin, N-acetylprocainamide, Phenytoin, and Theophylline. The modification involves repackaging these existing reagents for use on the Dimension Vista platform. The modification increases the number of tests per reagent pack by proportionally decreasing reagent and sample volumes while maintaining the same final sample/reagent concentration ratio in the test milieu. The device is used in clinical laboratory settings to perform diagnostic assays. The modification was validated through Failure Mode and Effect Analysis (FEMA) and verification of test performance to ensure no loss of precision or accuracy compared to the predicate Dimension platform reagents.
Clinical Evidence
Bench testing only. The sponsor performed a risk analysis (FMEA) and verification activities to confirm that the reduction in reagent and sample volumes maintained the same final concentration ratio as the predicate devices, ensuring equivalent performance.
Technological Characteristics
Reagent cartridges for clinical chemistry assays. Modification involves proportional reduction of reagent and sample volumes to increase tests per pack. Fundamental scientific technology remains consistent with previously cleared Dimension Flex reagent cartridges. No changes to detection methods or analytes.
Indications for Use
Indicated for quantitative measurement of digitoxin, digoxin, gentamicin, N-acetylprocainamide, phenytoin, or theophylline in human serum and plasma for therapeutic drug monitoring and overdose diagnosis. Prescription use only.
Regulatory Classification
Identification
A digitoxin test system is a device intended to measure digitoxin, a cardiovascular drug, in serum and plasma. Measurements obtained by this device are used in the diagnosis and treatment of digitoxin overdose and in monitoring levels of digitoxin to ensure appropriate therapy.
Predicate Devices
- Dimension® DGTX Flex® reagent cartridge (K990251)
- Dimension® DGNA Flex® reagent cartridge (K946153)
- Dimension® GENT Flex® reagent cartridge (K962819)
- Dimension® NAPA Flex® reagent cartridge (K032564)
- Dimension® PTN Flex® reagent cartridge (K911056)
- Dimension® THEO Flex® reagent cartridge (K862955)