← Product Code [JZO](/productcode/JZO) · K061794

# FIDIS TM THYRO, MODEL MX002 (K061794)

_Biomedical Diagnostics (Bmd) SA · JZO · Nov 21, 2006 · Immunology · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K061794

## Device Facts

- **Applicant:** Biomedical Diagnostics (Bmd) SA
- **Product Code:** [JZO](/productcode/JZO.md)
- **Decision Date:** Nov 21, 2006
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 866.5870
- **Device Class:** Class 2
- **Review Panel:** Immunology
- **Attributes:** Real-World Evidence

## Real-World Evidence

| Submission | Device | Sponsor | RWD Sources | RWE Use Summary | Key Tags |
| --- | --- | --- | --- | --- | --- |
| K061794 · Nov 21, 2006 | FIDIS TM THYRO, MODEL MX002 | Biomedical Diagnostics (Bmd) SA | Retrospective clinical serum samples (normal population and samples with potential biological interferences); Retrospective clinical serum samples used for method comparison | Retrospective clinical serum samples were used to determine the assay cut-off and to perform a method comparison study against the predicate ELISA device. | Retrospective clinical samples; Method comparison; Cut-off determination |

### Clinical Evidence

| Study Design | Population | Comparator | Key Endpoints |
| --- | --- | --- | --- |
| Retrospective analysis of clinical serum samples | 146 normal serum samples and samples with potential biological interferences; Sample Size: 146 | Not applicable for this study | Assay cut-off determination |
| Retrospective method comparison | 247 clinical serum samples (101 positive, 146 negative); Sample Size: 247 | ImmunoWELL TPO IgG and TG IgG ELISA assays | Percent agreement (positive, negative, overall) |

## Indications for Use

The FIDIS™ THYRO kit is a semi-quantitative homogeneous fluorescent-based microparticles immunoassay using flow cytometry readings. It is designed for the detection of antibodies directed against thyroperoxydase (TPO) and thyroglobuline (TG). The test system is used on serum samples as an aid in the diagnostic of auto-immune thyroid pathologies (Graves' disease and Hashimoto thryroiditis), in conjunction with clinical findings and other laboratory tests. The FIDIS™ THYRO kit is to be used on FIDIS™ Analyser, software and washer.

## Device Story

Multiplexed, semi-quantitative, fluorescent immunoassay for detection of TPO and TG autoantibodies in human serum. Device utilizes color-coded microspheres covalently coupled to TPO or TG antigens. Patient serum mixed with microspheres in 96-well plate; specific antibodies bind to antigens. Unbound material removed via filtration wash. Phycoerythrin-conjugated goat anti-human IgG added to form antigen/antibody/conjugate complex. FIDIS instrument uses red diode laser to identify microsphere type via fluorescence intensity and green laser to excite reporter conjugate for quantification. MLX-BOOSTER software calculates binding in IU/mL. Used in clinical laboratory settings by trained personnel. Output assists clinicians in diagnosing autoimmune thyroid conditions.

## Clinical Evidence

No clinical prospective/retrospective studies provided. Performance established via bench testing and method comparison against predicate ELISA assays using 247 serum samples. Positive percent agreement: 96.2% (TPO), 90.9% (TG). Negative percent agreement: 93.5% (TPO), 98.0% (TG). Precision/reproducibility evaluated with 14 samples; %CV <30% achieved. Analytical specificity tested against 96 samples representing various autoimmune disorders.

## Technological Characteristics

Multiplexed bead-based flow cytometric immunoassay. Components: color-coded microspheres, phycoerythrin-conjugated goat anti-human IgG. Energy source: red diode laser (bead identification) and green laser (reporter excitation). Connectivity: integrated with FIDIS Analyzer and MLX-BOOSTER software. Sample type: serum. Standardized against WHO 66/387 (TPO) and 65/93 (TG) reference materials.

## Regulatory Identification

A thyroid autoantibody immunological test system is a device that consists of the reagents used to measure by immunochemical techniques the thyroid autoantibodies (antibodies produced against the body's own tissues). Measurement of thyroid autoantibodies may aid in the diagnosis of certain thyroid disorders, such as Hashimoto's disease (chronic lymphocytic thyroiditis), nontoxic goiter (enlargement of thyroid gland), Grave's disease (enlargement of the thyroid gland with protrusion of the eyeballs), and cancer of the thyroid.

## Predicate Devices

- IMMUNOWELL THYROGLOBULIN TEST ([K905485](/device/K905485.md))
- IMMUNOWELL TPO (MICROSOME) TEST ([K905486](/device/K905486.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

1

# 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

A. 510(k) Number:
k061794

B. Purpose for Submission:
New Device

C. Measurand:
Thyroglobulin (TG) and Thyroperoxidase (TPO) autoantibodies

D. Type of Test:
Multiplex bead-based flow cytometric immunoassay

E. Applicant:
Biomedical Diagnostics S.A. (bmd)

F. Proprietary and Established Names:
FIDIS™ THYRO

G. Regulatory Information:

1. Regulation section:
21 CFR 866.5660 Multiple autoantibodies immunological test system
21 CFR 866.5870 Thyroid autoantibody immunological test system

2. Classification:
Class II

3. Product code:
JZO, System, Test, Thyroid Autoantibodies
JNL, Immunochemical, Thyroglobulin Autoantibodies

4. Panel:
Immunology (82)

H. Intended Use:

1. Intended use(s):
The FIDIS™ THYRO kit is a semi-quantitative homogeneous fluorescent-based microparticles immunoassay using flow cytometry readings. It is designed for the detection of antibodies directed against thyroperoxidase (TPO) and thyroglobulin (TG). The FIDIS™ THYRO kit uses serum only and is to be run on the FIDIS Analyzer, MLX-BOOSTER™ Software and Washer.

2. Indication(s) for use:
The test system is used as an aid in the diagnosis of autoimmune thyroid pathologies (Graves' disease and Hashimoto's thyroiditis), in conjunction with clinical findings and other laboratory tests.

3. Special conditions for use statement(s):
Prescription Use only.

4. Special instrument requirements:
The FIDIS™ THYRO is to be used as part of the FIDIS™ Instrument System (Luminex 100™ plus FIDIS™ MLX-Booster Software)
Caris™ System (diluting/dispensing device), optional

I. Device Description:
The device consists of the following: color-coded microspheres covalently coupled to either thyroglobulin or thyroperoxidase (ready-to-use); goat anti-human IgG

{1}

coupled to phycoerythrin (ready-to-use), a calibrator titered for each specificity (ready-to-use); a positive control IgG (to be diluted), a negative control (to be diluted), and 10x concentrated PBS-Tween.

# J. Substantial Equivalence Information:

1. Predicate device name(s):

General Biometrics, Inc ImmunoWELL™ Thyroglubulin Test

General Biometrics, Inc ImmunoWELL™ TPO (Microsome) Test

2. Predicate 510(k) number(s):

k905485 (TG); k905486 (TPO)

3. Comparison with predicate:

|  Similarities  |   |   |   |
| --- | --- | --- | --- |
|  Feature | New Device | Predicate | Predicate  |
|   | FIDISTM THYRO | ImmunoWELL™ TPO Antibodies | ImmunoWELL™ TG Antibodies  |
|  Intended Use | Determination of antibodies against TPO and TG | Determination of antibodies against TPO | Determination of antibodies against TG  |
|  Antigen | TPO: recombinant human thyroid peroxidase. TG: natural protein isolated from human thyroid glands | Recombinant human thyroid peroxidase | Purified human thyroglobulin  |
|  Sample type | Serum | Same | Same  |
|  Type of test | Semiquantitative | Same | Same  |
|  Controls | Positive and Negative using diluted human serum | Same | Same  |
|  Differences  |   |   |   |
| --- | --- | --- | --- |
|  Feature | New Device | Predicate | Predicate  |
|  Assay Type | Flow Cytometry | ELISA | ELISA  |
|  Solid Phase | Color-coded microspheres | Microtiter plate | Microtiter plate  |
|  Assay Format | Multiplex | Individual analytes | Individual analytes  |
|  Sample Dilution | 1:200 | 1:100 | 1:100  |
|  Reporter Conjugate | Phycoerythrin | HR Peroxidase | HR Peroxidase  |
|  Substrate Solution | None | TMB | TMB  |
|  Detection Method | Fluorescence/Flow cytometer | Colorimetry/ Spectrophotometer | Colorimetry/ Spectrophotometer  |
|  Diagnostic Values: Negative: Equivocal: Positive: | <130 IU/mL 130 -150 IU/mL >150 IU/mL | <45 IU/mL 45-65 IU/mL >65 IU/mL | <85 IU/mL 85-120 IU/mL >120 IU/mL  |

{2}

|  Differences  |   |   |   |
| --- | --- | --- | --- |
|  Feature | New Device | Predicate | Predicate  |
|  Calibrator | 1 concentration used to interpolate each antigenic specificity | 5 ready-to-use dilution | 5 ready-to use dilutions  |
|  Traceability | Anti-thyroid microsome serum WHO 66/387 and anti-thyroglobulin serum WHO 65/93 | Unknown | Unknown  |

K. Standard/Guidance Document Referenced (if applicable):
Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices

L. Test Principle:
The FIDISTM THYRO kit is a multiplexed, semiquantitative, fluorescent immunoassay performed on the FIDISTM System using MLX-BOOSTER Software, and allows the detection and identification of antibodies against thyroglubulin (TG) and thyroperoxidase (TPO). Diluted patient sera and microsphere suspensions precoated with either TPO or TG are mixed in a 96 well microtiter plate. TPO or TG specific antibodies in the patient sera, if present, bind to the immobilized antigen on the beads. Any unbound material is removed by performing a filtration wash step. Phycoerythrin-conjugated goat anti-human IgG is added to the plate and a further incubation performed. The conjugated anti-human IgG binds to the TPO or TG specific antibodies immobilized on the microsphere surface to form an antigen/antibody complex. The bead suspension is then analyzed by the FIDIS instrument. The FIDISTM Instrument uses a red diode laser beam to distinguish between the internally, color-coded microspheres for each antigen on the basis of its unique fluorescence intensity (red to orange), while a green laser beam excites the reporter conjugate, quantifying the fluorescence of the antibody captured by each microsphere. The degree of binding is calculated in biological units (IU/mL) using specific data software (MLX-BOOSTER). Measurement of the fluorescent signal from the final reaction allows the quantification of the presence or absence of autoantibodies.

M. Performance Characteristics (if/when applicable):
1. Analytical performance:
a. Precision/Reproducibility:
To evaluate intra-assay and inter-assay precision and reproducibility, a total of 14 serum samples with various concentrations of antibodies to TPO or TG representing the measuring range, were analyzed using the FIDISTM THYRO kit. For within-run, 6 TPO samples and 8 TG samples representing the measuring range were assayed 10 times in one run. For between-run, the same samples were assayed 2 times per run for 6 runs. The acceptance criteria %CV &lt;30% was achieved. The results are as follows:

{3}

|   | Within-run (10 tests in the same run) |   | Between-run (2 tests in 6 different runs)  |   |
| --- | --- | --- | --- | --- |
|   |  Mean value | CV (%) | Mean value | CV (%)  |
|  Antigen | 135 | 9 | 131 | 8  |
|  TPO | 194 | 3 | 169 | 12  |
|   |  215 | 7 | 195 | 12  |
|   |  351 | 6 | 309 | 13  |
|   |  612 | 3 | 562 | 7  |
|   |  935 | 6 | 890 | 9  |
|  TG | 109 | 4 | 114 | 11  |
|   |  110 | 10 | 111 | 10  |
|   |  125 | 4 | 125 | 9  |
|   |  180 | 7 | 169 | 11  |
|   |  194 | 7 | 182 | 10  |
|   |  396 | 5 | 334 | 15  |
|   |  730 | 3 | 645 | 10  |
|   |  1395 | 5 | 1292 | 9  |

Precision and reproducibility of the assays using the optional automated CARISTM system (diluting and dispensing device) was determined. A total of 11 serum samples (5 TPO and 5 TG) were assayed for within-run (10 times in one run) and between-run (4 times in 6 different runs). Results are as follows:

|  Antigen | Within-run (10 tests in the same run) |   | Between-run (4 tests in 6 different runs)  |   |
| --- | --- | --- | --- | --- |
|   |  Mean value | CV (%) | Mean value | CV (%)  |
|  TPO | 142 | 8 | 142 | 7  |
|   |  188 | 6 | 178 | 8  |
|   |  379 | 4 | 375 | 13  |
|   |  540 | 6 | 501 | 12  |
|   |  1013 | 6 | 1020 | 5  |
|  TG | 121 | 9 | 114 | 13  |
|   |  144 | 12 | 144 | 12  |
|   |  268 | 4 | 261 | 8  |
|   |  314 | 8 | 302 | 17  |
|   |  549 | 8 | 543 | 9  |
|   |  1838 | 5 | 1763 | 7  |

b. Linearity/assay reportable range: Linearity is not claimed for this assay.

c. Traceability, Stability, Expected values (controls, calibrators, or methods): Calibrator titers are expressed in International Units per mL (IU/mL) and are standardized against International Reference 66.387 WHO for anti-thyroperoxidase autoantibodies and International Reference 65/93 WHO for anti-thyroglobulin autoantibodies.

d. Detection limit:

{4}

Not Applicable

e. Analytical specificity:

Cross-reactivity with autoimmune antibodies common to other systemic autoimmune diseases was evaluated by testing 96 serum samples representing a spectrum of autoimmune diseases. Eight of the 96 samples were positive for TPO and 2 were positive for TG. The Limitations section of the package insert includes the statement "Hemolytic, lipemic, icteric or citrated samples, or samples with abnormal concentration of immunoglobulins, cryoglobulinemia or complement levels or samples with rheumatoid factor may confound the results of this assay. Use of these samples should be avoided."

The autoimmune disorders evaluated and results are as follows:

|  Crossreactive samples | Number of tested sera | Number of positive sample  |   |
| --- | --- | --- | --- |
|   |   |  TPO | TG  |
|  Cryoglobulin | 8 |  |   |
|  Complement | 30 | 1 | 1  |
|  Hypergammaglobulin | 13 | 4 |   |
|  IgG monoclonal immunoglobulins | 5 |  |   |
|  IgM monoclonal immunoglobulins | 17 | 1 |   |
|  Rheumatoid factor | 9 | 1 | 1  |
|  Hemolyzed sera | 6 |  |   |
|  Citrated plasma | 6 | 1 |   |
|  CIC | 1 |  |   |
|  Lipemic plasma | 1 |  |   |

f. Assay cut-off:

The assay cut-off of 150 IU/mL was determined by assaying 146 normal serum samples (50 normal and 96 with potential biological interferences). The following results were obtained and between the thresholds the results are considered equivocal (results ≤ 150 IU/mL and ≥ 130 IU/mL).

|  Percentiles of the distribution values | <130 IU/mL | <150 IU/mL  |
| --- | --- | --- |
|  TPO | 91.8% (134/146) | 92.5% (135/146)  |
|  TG | 98.6% (144/146) | 98.6% (144/146)  |

2. Comparison studies:

a. Method comparison with predicate device:

The FIDISTM THYRO assay was compared to the ImmunoWELLM TPO IgG and TG IgG ELISA assays by testing 247 samples (101 positive for one or both of the antigens, 146 negative samples). No information about age, gender, and clinical status was available. Equivocal results were considered negative for the purpose of calculating percent agreements.

{5}

|  TPO | ImmunoWELL TPO ELISA IU/mL  |   |   |   |
| --- | --- | --- | --- | --- |
|  FIDISTM THYRO IU/mL | >65 | 45-65 | <45 | Total  |
|  >150 | 76 | 9 | 2 | 87  |
|  130-150 | 0 | 3 | 1 | 4  |
|  <130 | 3 | 15 | 138 | 156  |
|  Total | 79 | 27 | 141 | 247  |
|  TG | ImmunoWELL TG ELISA IU/mL  |   |   |   |
| --- | --- | --- | --- | --- |
|  FIDISTM THYRO IU/mL | >120 | 85-120 | <85 | Total  |
|  >150 | 40 | 4 | 0 | 44  |
|  130-150 | 0 | 0 | 0 | 0  |
|  <130 | 4 | 21 | 178 | 203  |
|  Total 247 | 44 | 25 | 178 | 247  |
|  Antigen | Positive percent Agreement (%) | Negative percent Agreement (%) | Overall Agreement (%)  |
| --- | --- | --- | --- |
|  TPO | 96.2% (76/79) | 93.5% (157/168) | 94.3% (233/247)  |
|  TG | 90.9% (40/44) | 98.0% (199/203) | 97.6% (239/247)  |

Comparison of CARIS and manual method. A comparative study between the CARISTM Diluting and Dispensing System and the manual technique was performed on 40 samples.

|  TG | Manual FIDIS  |   |   |
| --- | --- | --- | --- |
|   |   |  Positive | Negative  |
|  CARISTM FIDIS | Positive | 19 | 1  |
|   |  Negative | 0 | 20  |
|  TPO | Manual FIDIS  |   |   |
| --- | --- | --- | --- |
|   |   |  Positive | Negative  |
|  CARISTM FIDIS | Positive | 20 | 0  |
|   |  Negative | 0 | 20  |
|  Antigenic Specificity | Positive percent Agreement (%) | Negative percent Agreement (%) | Overall Agreement (%)  |
| --- | --- | --- | --- |
|  TPO | 100 (20/20) | 100 (20/20) | 100 (40/40)  |
|  TG | 100 (19/19) | 95.24 (20/21) | 97.5 (39/40)  |

{6}

Linear Regression analysis of antigenic specificities with  $\mathrm{CARISTM}$ .

![img-0.jpeg](img-0.jpeg)

![img-1.jpeg](img-1.jpeg)

The reproducibility of the assay following the optional final wash and delayed analysis was assessed. Six samples following the overnight wash and delayed analysis were tested 6 times and results were compared to a test that was performed on the same day. Both sets of test results were similar and are shown below:

|  Sample | TPO |   |   |   | TG  |   |   |   |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
|   |  A |   | B |   | A |   | B  |   |
|   |  mean | CV% | mean | CV% | mean | CV% | mean | CV%  |
|  1 | 199 | 8 | 183 | 4 | 3 | 16 | 2 | 23  |
|  2 | 239 | 5 | 202 | 3 | 2 | 20 | 2 | 25  |
|  3 | 813 | 8 | 692 | 14 | 63 | 8 | 51 | 11  |
|  4 | 12 | 7 | 10 | 4 | 62 | 2 | 52 | 4  |
|  5 | 42 | 14 | 35 | 10 | 238 | 6 | 211 | 8  |
|  6 | 866 | 11 | 713 | 6 | 303 | 5 | 263 | 7  |

# b. Matrix comparison:

Serum is the only recommended matrix.

{7}

8

3. Clinical studies:
a. Clinical Sensitivity: Not available
b. Clinical specificity: Not available
c. Other clinical supportive data (when a. and b. are not applicable): Not applicable

4. Clinical cut-off:
Results below 130 IU/mL are considered negative
Between 130 and 150 IU/mL are considered borderline
Above 150 IU/mL are considered positive

5. Expected values/Reference range:
Expected values in the normal population should be negative, however thyroid antibodies may be present in apparently healthy adults.

|  Pathology | Anti-TPO | Anti-TG  |
| --- | --- | --- |
|  Hashimoto | 99% | 85%  |
|  Thyroid atrophy | 99% | 85%  |
|  Basedow/Graves | 75% | 50%  |
|  Healthy adults | 4-8%
15% (over 60) | 4-8%
15% (over 60)  |

N. Proposed Labeling:
The labeling is sufficient and it satisfies the requirements of 21 CFR Part 809.10.

O. Conclusion:
The submitted information in this premarket notification is complete and supports a substantial equivalence decision.

---

**Source:** [https://fda-staging.innolitics.com/device/K061794](https://fda-staging.innolitics.com/device/K061794)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
