← Product Code [HRY](/productcode/HRY) · K061681

# REPICCI II METAL BACK INLAY UNICOMPARTMENTAL TIBIAL BEARING COMPONENT (K061681)

_Biomet Manufacturing Corp · HRY · Oct 19, 2006 · Orthopedic · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K061681

## Device Facts

- **Applicant:** Biomet Manufacturing Corp
- **Product Code:** [HRY](/productcode/HRY.md)
- **Decision Date:** Oct 19, 2006
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3530
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

Partial replacement of the articulating surfaces of the knee when only one side of the joint is affected due to compartmental primary degenerative or post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity or revision of previous arthroplasty. The devices covered in this 510(k) are intended to be used with Repicci Femoral component. The device is intended to be used with bone cement.

## Device Story

Repicci II Metal Back Inlay Unicompartmental Tibial Bearing Component is a prosthetic implant for partial knee replacement. Device consists of ultra-high molecular weight polyethylene (UHMWPE) with a thin corrugated metal plate molded into the inferior surface. Implanted by orthopedic surgeons during knee arthroplasty procedures to replace articulating surfaces of the knee joint. Used in conjunction with Repicci Femoral component and bone cement for fixation. Provides a bearing surface for the femoral component to restore joint function in patients with compartmental degenerative disease or trauma. Benefits include pain relief and improved joint mobility.

## Clinical Evidence

No clinical data provided as a basis for substantial equivalence. Substantial equivalence established via non-clinical laboratory testing.

## Technological Characteristics

Tibial component for uni-condylar knee replacement. Materials: UHMWPE with molded corrugated metal plate. Fixation: Cemented. Available in six profiles and two thicknesses. Class II device (21 CFR 888.3530).

## Regulatory Identification

A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace part of a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that consist of a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (§ 888.3027).

## Predicate Devices

- Repicci II® Unicondylar Knee ([K971938](/device/K971938.md))
- Repicci III® Unicondylar Knee All Poly Tibial Components ([K980665](/device/K980665.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

BIOMET

KO61681

# 510(k) Summary

| Preparation Date:    | June 9, 2006                                                                                    |
|----------------------|-------------------------------------------------------------------------------------------------|
| Applicant/Sponsor:   | Biomet Manufacturing Corp.<br>P.O. Box 587<br>Warsaw, Indiana 46581-0587                        |
| Contact Person:      | Lester F. Padilla                                                                               |
| Proprietary Name:    | Repicci II® Metal Back Inlay Unicompartmental Tibial Bearing Component                          |
| Common Name:         | Tibial component for uni-condylar knee replacement                                              |
| Classification Name: | Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis<br>(21 CFR 888.3530) |
|                      | OCT 19 2006                                                                                     |

## Legally Marketed Devices To Which Substantial Equivalence Is Claimed:

- 1. Repicci II® Unicondylar Knee (K971938)
- 2. Repicci III® Unicondylar Knee All Poly Tibial Components (K980665)

#### Device Description:

The Repicci II® Metal Back Inlay Unicompartmental Tibial component comprised of ultra-high molecular polyethylene (UHMWPE), with a thin corrugated metal plate molded into the inferior surface of the device. The tibial components are available in six profiles and two thicknesses and is intended for cemented fixation.

## Intended Use:

Partial replacement of the articulating surfaces of the knee when only one side of the joint is affected due to compartmental primary degenerative or post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity or revision of previous arthroplasty. The devices covered in this 510(k) are intended to be used with Repicci Femoral component. The device is intended to be used with bone cement.

Summary of Technologies: The technological characteristics (material, design, sizing, and indications) of the Repicci II® Metal Back Inlay Unicompartmental Tibial Bearing Component are similar or identical to the predicate devices.

Non-Clinical Testing: Non-clinical laboratory testing was performed to determine substantial equivalence. The results indicated that the device was functional within its intended use.

Clinical Testing: None provided as a basis for substantial equivalence.

All trademarks are property of Biomet, Inc.

MAILING ADDRESS P.O. Box 587 Warsaw, IN 46581-0587

그

SHIPPING ADDRESS 56 E. Bell Drive Warsaw, IN 46582

OFFICE 574.267.6639

FAX
574.267.8137

E-MAH. biomet@biomet.com 

{1}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/1/Picture/1 description: The image shows the seal for the Department of Health & Human Services - USA. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an image of an eagle.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Biomet. Inc. % Lester F. Padilla, RAC Regulatory Affairs Associate P.O. Box 587 56 East Bell Drive Warsaw, Indiana 46581

OCT 1 9 2006

Re: K061681

Trade/Device Name: Repicci II® Metal Back Inlay Unicompartmental Tibial Bearing Component Regulation Number: 21 CFR 888.3530 Regulation Name: Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis Regulatory Class: Class II Product Code: HRY Dated: September 18, 2006 Received: September 21, 2006

Dear Mr. Padilla:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21. Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

{2}------------------------------------------------

Page 2 – Mr. Lester F. Padilla

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120 . Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours,

To My Son

Mark N. Melkerson Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

# Indications for Use

510(k) Number (if known):

Device Name: Repicci II® Metal Back Inlay Unicompartmental Tibial Bearing Component

Indications for Use:

Partial replacement of the articulating surfaces of the knee when only one side of the joint is affected due to compartmental primary degenerative or post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity or revision of previous arthroplasty.

The devices covered in this 510(k) are intended to be used with Repicci Femoral component.

The device is intended to be used with bone cement.

Prescription Use _________X (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use NO (21 CFR 807 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Page 1 of 1

**(Division Sign-Off)**

Division of General, Restorative, and Neurological Devices

510(k) Number_ L001141

---

**Source:** [https://fda-staging.innolitics.com/device/K061681](https://fda-staging.innolitics.com/device/K061681)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com