TheraSeed® Palladium-103 Implants are indicated for tumors with any of the following characteristics: . Localized, . Unresectable, . Low to moderate radiosensitivity. The tumors may be of the following types: . Superficial; . Intrathoracic; . Intra-abdominal; . Lung, pancreas, prostate, head and neck; . Residual following external beam or excision of primary tumor; . Recurrent.
Device Story
Palladium-103 Seed Implant Kits consist of pre-manufactured TheraSeed® Palladium-103 brachytherapy seeds packaged in various sterile and non-sterile configurations. Device functions as a radioactive source for interstitial brachytherapy; seeds are implanted directly into tumor tissue to deliver localized radiation. Used by clinicians in clinical settings for treatment of localized, unresectable, or recurrent tumors. Device provides targeted radiation therapy; intended to treat malignancy while sparing surrounding healthy tissue. No change to seed technology or operation compared to predicate.
Clinical Evidence
No clinical data provided; substantial equivalence based on technological characteristics and design similarity to legally marketed predicate devices.
Technological Characteristics
Palladium-103 radionuclide brachytherapy source. Seeds are identical to those cleared under K010283. Packaging configurations are identical to those cleared under K043246. Device is a passive radioactive implant.
Indications for Use
Indicated for patients with localized, unresectable, low to moderate radiosensitivity tumors, including superficial, intrathoracic, intra-abdominal, lung, pancreas, prostate, head and neck tumors, as well as residual or recurrent tumors.
Regulatory Classification
Identification
A radionuclide brachytherapy source is a device that consists of a radionuclide which may be enclosed in a sealed container made of gold, titanium, stainless steel, or platinum and intended for medical purposes to be placed onto a body surface or into a body cavity or tissue as a source of nuclear radiation for therapy.
Special Controls
*Classification.* Class II (special controls). A prostate seeding kit intended for use with a radionuclide brachytherapy source only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.
{0}------------------------------------------------
K060636
Bard Urological Division C. R. Bard, Inc. 8195 Industrial Blvd. Covington, GA 30014
APR 1 9 2006
Image /page/0/Picture/3 description: The image shows the word "BARD" in a stylized, bold font. The letters are thick and have a rounded appearance. The "A" in "BARD" is designed with a unique shape, resembling a triangle with a horizontal line across the middle. The overall design of the word gives it a modern and distinctive look.
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS INFORMATION
This 510(k) summary of safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990.
### A. SUBMITTER INFORMATION:
Contact Person's Fax:
Date of Preparation:
| Submitter's Name: | C. R. Bard, Inc. | |
|------------------------------------|--------------------------|--|
| | Bard Urological Division | |
| Address: | 13183 Harland Dr. | |
| | Covington, GA 30014 | |
| Contact Person: | Julie J. Bassett | |
| Contact Person's Telephone Number: | 678-342-4921 | |
#### B. DEVICE NAME:
| Trade Name(s): | Palladium-103 Seed Implant Kits |
|-----------------------|----------------------------------------------------------------|
| Common/Usual Name: | Brachytherapy seed implants |
| Classification Names: | 90KXK - Source, Brachytherapy, Radionuclide<br>21 CFR 892.5730 |
770-788-5517
March 9, 2006
#### C. PREDICATE DEVICE NAME:
Trade Name(s): TheraSeed® Palladium-103 Implants and BrachySource® Brachytherapy Seed Implants
#### D. DEVICE DESCRIPTION:
The Pd-103 Seed Implant Kits will be offered using TheraSeed® Palladium-103 Implants, which are produced and marketed commercially by Theragenics, Inc. under the 510(k) K010283. There is no change to the seeds produced by Theragenics and marketed under the name TheraSeed® Palladium-103 devices. These seeds will be packaged in various sterile and non-sterile configurations. These configurations are the same as the predicate described in K043246.
The principles of operation and fundamental scientific technology have not changed. Reference K043246 and K010283 for a detailed description.
TheraSeed® is a registered trademark of Theragenics Corporation®
{1}------------------------------------------------
# E. INTENDED USE:
TheraSeed® Palladium-103 Implants are indicated for tumors with any of the following characteristics:
- . Localized,
- Unresectable,
- Low to moderate radiosensitivity.
The tumors may be of the following types:
- . Superficial;
- . Intrathoracic;
- . Intra-abdominal;
- 트 Lung, pancreas, prostate, head and neck;
- . Residual following external beam or excision of primary tumor;
- . Recurrent.
The intended use has not changed from Theragenics 510(k), K010283.
## ﺎﻧﺎ TECHNOLOGICAL CHARACTERISTICS SUMMARY:
The subject device, Palladium-103 Implant Kits, has the same intended use, design and fundamental scientific technology as the predicate devices.
# G. PERFORMANCE DATA SUMMARY:
The appropriate testing for the Palladium-103 Seed Implant Kits was conducted.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services USA. The logo features a stylized eagle with three stripes forming its body and wings. The eagle is enclosed in a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" surrounding it.
Food and Drug Administration 9200 Corporate Blvd. Rockville MD 20850
APR 1 9 2006
Ms. Julie J. Bassett, RAC Regulatory Affairs Specialist C.R. Bard, Inc. Bard Urological Division 8195 Industrial Blvd. COVINGTON GA 30014
Re: K060636
Trade/Device Name: Palladium-103 Seed Implant Kits Regulation Number: 21 CFR 892.5730 Regulation Name: Radionuclide brachytherapy source Regulatory Class: II Product Code: KXK Dated: March 9, 2006 Received: March 10, 2006
Dear Ms. Bassett:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Image /page/2/Picture/10 description: The image shows a logo with the text "FDA Centennial 1906-2006". The logo is circular and contains the letters "FDA" in a bold font. The text "Protecting and Promoting Public" is also visible in the image.
{3}------------------------------------------------
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that I lease of a rison determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally promated predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter:
| 21 CFR 876.xxxx | (Gastroenterology/Renal/Urology) | 240-276-0115 |
|-----------------|----------------------------------|--------------|
| 21 CFR 884.xxxx | (Obstetrics/Gynecology) | 240-276-0115 |
| 21 CFR 892.xxxx | (Radiology) | 240-276-0120 |
| Other | | 240-276-0100 |
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html
Sincerely yours.
Nancy C. Brogdon
Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
C.R. Bard, Inc., Bard Urological Division Palladium-103 Seed Implant Kits Premarket Notification [510(k)]
1.3 Indications for Use Statement
510(k) Number (if known):
Device Name: Palladium-103 Seed Implant Kits_
Indications for Use:
TheraSeed® Palladium-103 Implants are indicated for tumors with any of the following characteristics:
- . Localized,
- l Unresectable,
- Low to moderate radiosensitivity. 트
The tumors may be of the following types:
- l Superficial:
- . Intrathoracic;
- 일 Intra-abdominal;
- 1 Lung, pancreas, prostate, head and neck;
- 발 Residual following external beam or excision of primary tumor;
- 지 Recurrent.
| Prescription Use | X |
|-----------------------------|---|
| (Part 21 CFR 801 Subpart D) | |
AND/OR
| Over-The-Counter Use | |
|------------------------|--|
| (21 CFR 801 Subpart C) | |
(PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEEDED)
CONCURRENCE OF CDRH, OFFICE OF DEVICE EVALUATION (ODE)
David A. Segrim
(Division Sign-Off) V
Division of Reproductive, Abdominal,
anır Radiological Devices K060636
(Recommended Format 11/13/2003)
TheraSeed® is a registered trademark of Theragenics Corporation®.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.