← Product Code [IMI](/productcode/IMI) · K053546

# SONICATOR 740, MODEL ME 740 (K053546)

_Mettler Electronics Corp. · IMI · May 4, 2006 · Physical Medicine · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K053546

## Device Facts

- **Applicant:** Mettler Electronics Corp.
- **Product Code:** [IMI](/productcode/IMI.md)
- **Decision Date:** May 4, 2006
- **Decision:** SESE
- **Submission Type:** Abbreviated
- **Regulation:** 21 CFR 890.5300
- **Device Class:** Class 2
- **Review Panel:** Physical Medicine
- **Attributes:** Therapeutic

## Indications for Use

Ultrasound delivered to the body using an efficient couplant provides deep heating effects to body tissues. Ultrasound delivered at a frequency of 1 MHz penetrates to a depth of approximately 5 centimeters while ultrasound at a frequency of 3.3 or 3.2 MHz penetrates tissue to a depth of approximately 1-2 cm. When therapeutic ultrasound is delivered to the body at intensities capable of generating a deep tissue temperature increase, some or all of the following effects may occur: 1. Pain relief 2. Reduction of muscle spasm 3. Localized increase in blood flow 4. Increase range of motion of contracted joints using heat and stretch techniques.

## Device Story

Sonicator 740 (Model ME 740) is an ultrasonic diathermy device. It generates therapeutic ultrasound at 1 MHz (deep penetration, ~5 cm) or 3.3/3.2 MHz (shallow penetration, 1-2 cm). Device is operated by clinicians in a professional setting to deliver deep tissue heating via an acoustic couplant. Output effects include pain relief, muscle spasm reduction, increased blood flow, and improved joint range of motion. Clinicians use the device to treat musculoskeletal conditions; clinical decision-making is guided by the desired therapeutic heating effect.

## Clinical Evidence

No clinical data provided; substantial equivalence is based on technological characteristics and intended use consistent with established ultrasonic diathermy devices.

## Technological Characteristics

Ultrasonic diathermy device; operates at 1 MHz and 3.3/3.2 MHz frequencies; utilizes piezoelectric transducer for ultrasound generation; requires external acoustic couplant; Class II device (Product Code IMI).

## Regulatory Identification

An ultrasonic diathermy for use in applying therapeutic deep heat for selected medical conditions is a device that applies to specific areas of the body ultrasonic energy at a frequency beyond 20 kilohertz and that is intended to generate deep heat within body tissues for the treatment of selected medical conditions such as relief of pain, muscle spasms, and joint contractures, but not for the treatment of malignancies.

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/1 description: The image shows the logo for the Department of Health and Human Services (HHS) in the USA. The logo features a stylized symbol of three human profiles facing right, stacked on top of each other, with flowing lines beneath them. The text "DEPARTMENT OF HEALTH AND HUMAN SERVICES - USA" is arranged in a circular fashion around the symbol.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

OCT 1 6 2006

Mettler Electronics Corp. % Mr. Robert E. Fleming Director, QA/RA 1333 South Claudina Street Anaheim, California 92805

Re: K053546

Trade/Device Name: Sonicator 740, Model ME 740 Regulation Number: 21 CFR 890.5300 Regulation Name: Ultrasonic diathermy Regulatory Class: Class II Product Code: IMI Dated: April 24, 2006 Received: April 25, 2006

Dear Mr. Fleming:

This letter corrects our substantially equivalent letter of May 4, 2006.

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050.

{1}------------------------------------------------

Page 2 - Mr. Robert E. Fleming

This letter will allow you to continue marketing your device as described in your Section 510(k) This letter will anow you to continue mag of substantial equivalence of your device to a legally premated predicated on "ce results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please it you don't specific as nollance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small other general international and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html

Sincerely yours,

Barbara buchuk

Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

## Indications for Use

510(k) Number (if known):

K053546

Sonicator® 740, Model ME 740 Device Name:

Indications for Use:

Ultrasound delivered to the body using an efficient couplant provides deep heating effects to body tissues. Ultrasound delivered at a frequency of 1 MHz penetrates to a depth of approximately 5 centimeters while ultrasound at a frequency of 3.3 or 3.2 MHz penetrates tissue to a depth of approximately 1-2 cm.

When therapeutic ultrasound is delivered to the body at intensities capable of generating a deep tissue temperature increase, some or all of the following effects may occur:

- 1. Pain relief
- 2. Reduction of muscle spasm
- 3. Localized increase in blood flow
- 4. Increase range of motion of contracted joints using heat and stretch techniques.

Prescription Use (Per CFR 801 Subpart D)

AND/OR

Over the Counter Use (Per CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH Office of Device Evaluation (ODE)

Office of Device Evaluation (ODE)

Division of General, Restorative, and Neurological Devices

**510(k) Number** K053546

Image /page/2/Picture/19 description: The image shows a black and white abstract pattern. The pattern is composed of many small black dots and shapes clustered together. The density of the black elements varies across the image, with some areas appearing more concentrated and others more sparse.

---

**Source:** [https://fda-staging.innolitics.com/device/K053546](https://fda-staging.innolitics.com/device/K053546)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com