The Commander III device is for use by patients to collect and transmit general health questions and patient vital sign data (such as weight, blood pressure, glucose, pulse oximetry, peak flow) between the patient, typically at home, and a health care professional at a remote site. Contraindications, Precautions and Warnings: The Commander III device makes no interpretation, evaluation, medical judgments or recommendations for treatment. Clinical judgment and experience are required to check and interpret the information transmitted. The Commander III is not intended as a substitute for medical care.
Device Story
Commander III functions as a telemonitoring hub; collects patient vital signs via RS232-connected peripheral devices (scales, blood pressure meters, glucometers, peak flow meters, pulse oximeters); prompts users with health-related questions via display; stores and transmits data via telephone modem to remote clinical monitoring stations. Operated by patients at home; data reviewed by healthcare professionals. Device performs no medical interpretation or treatment recommendations; clinical judgment required for data review. Benefits include remote patient monitoring and improved data transmission between home and clinical settings.
Clinical Evidence
Bench, laboratory, and clinical testing performed. Results indicate the device is as safe and effective as the predicate device.
Technological Characteristics
Electronic printed circuit boards in ABS enclosure. Oscillometric blood pressure measurement principle. Connectivity via multiple RS-232 ports and telephone modem (Part 68 approved). Power source: AC adapter. Dimensions: 2.7" x 6.8" x 8.9". Memory: 200 measurements. Complies with UL/IEC 60601-1 and IEC 60601-1-2. Patient contact materials: Nylon cuff.
Indications for Use
Indicated for patients at home to collect and transmit vital signs (weight, blood pressure, glucose, pulse oximetry, peak flow) and answer health questions for remote review by healthcare professionals. Not for use as a substitute for medical care.
Regulatory Classification
Identification
A noninvasive blood pressure measurement system is a device that provides a signal from which systolic, diastolic, mean, or any combination of the three pressures can be derived through the use of tranducers placed on the surface of the body.
Predicate Devices
A&D Medical UA-767PC Digital Blood Pressure Monitor (K982481)
Submission Summary (Full Text)
{0}------------------------------------------------
K053304
DEC 3 0 2005
## EXHIBIT 2
510K Summary Cardiocom 1260 Park Road Chanhassen, MN 55317 Toll-Free: 888-243-8881 Tel: 952-474-4149 Fax: 952-474-4372 Contact: Daniel Cosentino, President Date: November 19, 2005
- 1 . Identification of the device Proprietary-Trade Name: Cardiocom Commander III Non-Invasive Automated Blood Pressure Monitor Classification Name: DXN, SYSTEM, MEASUREMENT, BLOOD-PRESSURE, NON-INVASIVE. Common/Usual Name: Noninvasive Blood Pressure Measurement System
- 2. Equivalent legally marketed devices This product is similar in function and design to predicate K982481 A&D Medical UA-767PC Digital Blood Pressure Monitor
- 3. Indications for Use (intended use). The Commander III device is for use by patients to collect and transmit general health questions and patient vital sign data (such as weight, blood pressure, glucose, pulse oximetry, peak flow) between the patient, typically at home, and a health care professional at a remote site. Contraindications, Precautions and Warnings: The Commander III device makes no interpretation, evaluation, medical judgments or recommendations for treatment. Clinical judgment and experience are required to check and interpret the information transmitted. The Commander III is not intended as a substitute for medical cars in o
- 4. Description of the Device. Commander III is similar to a simple personal computer with a modem that stores and transmits data. Commander III connects to a user's telephonel winn at home. It has a display that asks health related questions to which the user can respond 'Yes', 'No', or select from a list. It also has inputs for devices such as weight scales, blood pressure meters, glucometers, peak flow meters and pulse oximeters. These devices download data through a RS232 connection. The functionality of these devices not been modified; they are used as supplied from the manufacturer.
### న్. Safety and Effectiveness, comparison to predicate device The results of bench, laboratory, and clinical testing indicates that the new device is as safe and effective as the predicate device.
{1}------------------------------------------------
| Designation | K982481 A&D Medical UA-767PC<br>Digital Blood Pressure Monitor | Commander III |
|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Operating Principle | Oscillometric automated blood pressure<br>monitoring | SAME |
| Indications | The UA-767PC is designed to be used by end<br>users who are eighteen (18) years and older at<br>home and doctor/nurse office to monitor their<br>blood pressure (systolic and diastolic) and pulse<br>rate. At the end of each measurement, the<br>results will be stored in the UA-767PC<br>memory. UA-767PC through its<br>communications port can also transfer the<br>measurements stored in memory to other<br>electronic devices, such as a PC, a modem, or a<br>printer. | The Commander III device is for use by<br>patients to collect and transmit general<br>health questions and patient vital sign data<br>(such as weight, blood pressure, glucose,<br>pulse oximetry, peak flow) between the<br>patient, typically at home, and a health<br>care professional at a remote site.<br>Contraindications, Precautions and<br>Warnings: The Commander III device<br>makes no interpretation, evaluation,<br>medical judgments or recommendations<br>for treatment. Clinical judgment and<br>experience are required to check and<br>interpret the information transmitted. The<br>Commander III is not intended as a<br>substitute for medical care |
| Display | LCD: Systolic, Diastolic, Pulse | SAME |
| Controls | Start, pressure select | Yes, No, Up-arrow, Down-arrow, Four<br>"selection buttons" |
| Power supply | 4-A A alkaline batteries | AC Adapter only |
| External dimensions | 2.7" tall 4.4" deep 6.5" wide | 2.7" tall 6.8" deep 8.9" wide |
| Memory | 126 measurements | 200 measurements. Last measurement is<br>sent over the phone line. |
| Weight | 0.32 kg without batteries | 0.8kg without Blood Pressure cuff |
| Cuff Arm<br>Circumference Range | 5.1 inches -17.7 inches (small, medium, large<br>cuff sizes) | 7 inches-16.5 inches (small, medium, large<br>cuff sizes) |
| OTC or prescription | OTC | Prescription |
| Standard | ANSI/AAMI SP10: 1992+A1 | SAME |
| Electrical Safety | UL/IEC 60601-1 | UL/IEC 60601-1 |
| Electromagnetic<br>compatibility | IEC 60601-1-2 | IEC 60601-1-2 |
| Patient Contact<br>Materials | Nylon Cuff | SAME |
| Designation | K982481 A&D Medical UA-767PC<br>Digital Blood Pressure Monitor | Commander III |
| Description | This home blood pressure monitor<br>communicates with your information hub<br>through a serial communication cable and port.<br>Real-time communication is achieved by sending<br>the blood pressure measurement to the<br>information hub immediately. The UA-767PC<br>can also operate in a batch-mode to send up to<br>126 measurements with time and date in a single<br>request command. System integrators can<br>provide units to remotely located patients<br>enabling them to monitor their blood pressure at<br>home. Combine this blood pressure monitor and<br>the LifeSource™ UC-321 personal scale and you<br>have a foundation for a complete telemonitoring<br>system. | The Commander III device is for use by<br>patients to collect and transmit general<br>health questions and the following patient<br>vital signs data: Non-invasive blood<br>pressure measurement, Non-invasive blood<br>oxygen saturation measurement using pulse<br>oximetry, In vitro diagnostic quantitative<br>measurement of glucose in fresh capillary<br>whole blood, Non-invasive measurement of<br>lung peak flow, and Patient weight using a<br>stand-on electronic scale. The results of<br>these measurements are transmitted to a<br>computer monitoring station in a clinical<br>setting via common telephone lines from<br>the patient's home setting. For sale by or on<br>the order of a physician. |
| Communication<br>capability | Serial RS-232 with PC | Multiple serial RS-232 ports and telephone<br>modem Part 68 approved |
| Measurement Range | Pressure: 20 mmHg to 280 mmHg; Pulse: 40 to<br>200 pulses/minute | SAME (from AAMI) |
| Accuracy | Pressure: ±3 mmHg or ±2%, whichever is<br>greater; Pulse: ±5% | SAME (from AAMI) |
| Pressurization | Automatic, using micropump | Automatic |
| Operating Environment | 50° - 104° F (10° to 40° C) | SAME (from AAMI) |
Electronic printed circuit boards inside an ABS
-
enclosure
#### Comparison matrix – new vs. Predicate device 6.
Construction
Electronic printed circuit boards inside an
A BS enclosure
{2}------------------------------------------------
#### 7. Conclusion
After analyzing bench, test laboratory, and clinical testing data, it is the conclusion of Cardiocom that the Cardiocom Commander III is as safe and effective as the predicate device, has essentially no significant technological differences, and has no new indications for use, thus rendering it substantially equivalent to the predicate device.
{3}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle or bird with three curved lines forming its body and wings. The logo is encircled by the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES - USA" arranged in a circular fashion around the bird symbol.
DEC 3 0 2005
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Cardiocom LLC c/o Mr. Mark Job Regulatory Technology Services, LLC 1394 25th Street NW Buffalo, MN 55313
Re: K053304
Trade Name: Cardiocom Commander III Regulation Number: 21 CFR 870.1130 Regulation Name: Non-Invasive Blood Pressure Measurement System Regulatory Class: Class II (two) Product Code: DXN Dated: December 12, 2005 Received: December 13, 2005
Dear Mr. Job:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 - Mr. Mark Job
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
Bhimmar for
Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use
510(k) Number (if known) _________________
Device Name: Cardiocom Commander III
Indications For Use:
The Commander III device is for use by patients to collect and transmit general health questions and patient vital sign data (such as weight, blood pressure, glucose, pulse oximetry, peak flow) between the patient, typically at home, and a health care professional at a remote site.
Contraindications, Precautions and Warnings:
The Commander III device makes no interpretation, evaluation, medical judgments or recommendations for treatment. Clinical judgment and experience are required to check and interpret the information transmitted. The Commander III is not intended as a substitute for medical care.
Prescription Use × (Part 21 CFR 801 Subpart D) AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
B. L. Zimmerman
Division Supt. O.S.
Division of Cardiovascular Devices
510(k) Number K053304
Page 1 of 1
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.