Browse hierarchy Radiology (RA) Subpart B — Diagnostic Devices 21 CFR 892.1550 Product Code IYN K053258 — EUB-6500 DIAGNOSTIC ULTRASOUND SCANNER
EUB-6500 DIAGNOSTIC ULTRASOUND SCANNER
K053258 · Hitachi Medical Corp. · IYN · Dec 9, 2005 · Radiology
Device Facts
Record ID K053258
Device Name EUB-6500 DIAGNOSTIC ULTRASOUND SCANNER
Applicant Hitachi Medical Corp.
Product Code IYN · Radiology
Decision Date Dec 9, 2005
Decision SESE
Submission Type Special
Regulation 21 CFR 892.1550
Device Class Class 2
Attributes Pediatric
Indications for Use
Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
Device Story
The EUB-6500 is a diagnostic ultrasound scanner used in clinical settings by healthcare professionals. It processes ultrasonic pulsed echo and Doppler signals from various compatible transducers to generate real-time images and fluid flow data. The system supports multiple modes, including B-mode, M-mode, Pulsed Wave Doppler (PWD), Continuous Wave Doppler (CWD), Color Doppler, and advanced features like harmonic and 3D imaging. Clinicians use the displayed images and measurements to guide diagnostic assessments and interventional procedures, such as percutaneous biopsies. The device aids in clinical decision-making by providing visual and quantitative data for a wide range of anatomical structures and physiological conditions, potentially improving diagnostic accuracy and patient management.
Clinical Evidence
Bench testing only. The submission relies on performance data, acoustic output measurements, and verification of compliance with established safety standards for diagnostic ultrasound systems. No clinical trials were required or presented.
Technological Characteristics
Class II diagnostic ultrasound system. Supports B, M, PWD, CWD, and Color Doppler modes. Includes harmonic and 3D imaging capabilities. Compatible with a wide range of transducers (e.g., EUP-B514, EUP-C312T, EUP-L65). Connectivity via standard ultrasound interfaces. Not shipped sterile.
Indications for Use
Indicated for diagnostic ultrasound imaging or fluid flow analysis of the human body, including fetal, abdominal, intra-operative, pediatric, small organ, neonatal/adult cephalic, trans-rectal, trans-vaginal, musculo-skeletal, cardiac, and peripheral vessel applications, with specific modes including B, M, PWD, CWD, Color Doppler, and harmonic/3D imaging.
Regulatory Classification
Identification An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended to determine stationary body tissue characteristics, such as depth or location of tissue interfaces or dynamic tissue characteristics such as velocity of blood or tissue motion. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Predicate Devices
Submission Summary (Full Text)
{0}
K 053258
DEC 9 2005
HITACHI
Basic Information
| 4.2.1 | Manufacturers Name (Ultrasound Scanner): | Hitachi Medical Corporation |
| --- | --- | --- |
| | Address: | Hitachi Kamakurabashi Bldg., 1-1-14
Uchi-kanda, Chiyoda-ku
Tokyo 101-0047 Japan |
| | Corresponding Official: | Doug Thistlethwaite
Manager, Regulatory Affairs |
| | Address: | Hitachi Medical Systems America, Inc.
1959 Summit Commerce Park
Twinsburg, Ohio 44087 |
| | Telephone: | (330) 425-1313 |
| 4.2.2 | Initial Distributor (Ultrasound Scanner): | Hitachi Medical Systems America, Inc. |
| | Address: | 1959 Summit Commerce Park
Twinsburg, Ohio 44087 |
| | Telephone: | (330) 425-1313 |
| 4.2.3 | Device Name: | EUB-6500 Diagnostic Ultrasound Scanner |
| 4.2.4 | Common Name: | Diagnostic Ultrasound Unit |
| 4.2.5 | Classification | |
| | Regulatory Class: | Class II |
| | Review Category: | Tier II |
| | | FR Number
Product Codes |
| | Ultrasonic Pulsed Echo and Pulsed Doppler Imaging System | 892.1550
90-IYN |
| | Diagnostic Ultrasound Transducer | 892.1570
90-ITX |
| 4.2.6 | Establishment Registration Number: | Hitachi Medical Corp. (Japan) 8030405
Hitachi Medical Systems America, Inc. (USA) 1528028 |
| 4.2.7 | 514 Performance Standards: | None |
| 4.2.8 | Special Controls: | Special Report – to be filed at a later date |
| 4.2.9 | Prescription Status: | Prescription Device |
| 4.2.10 | Manufacturing Location (Ultrasound Scanner): | Hitachi Medical Corporation - Kashiwa Works
2-1 Shintoyofuta
Kashiwa-shi, Chiba-ken
277-0804 Japan |
| 4.2.11 | Sterilization Site(s): | N/A Device is not shipped as sterile. |
| 4.2.12 | Reason for Submission: | Modification to existing product |
| 4.2.13 | TRACK Followed for Submission: | Track 3 |
HITACHI Medical Systems America, Inc.
© 2005 All Rights Reserved
{1}
DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Health Service
Food and Drug Administration
9200 Corporate Boulevard
Rockville MD 20850
DEC 9 2005
Hitachi Medical Corporation
% Mr. Doug Thistlewaite
Manager, Regulatory Affairs
Hitachi Medical Systems America, Inc.
1959 Summit Commerce Park
TWINSBURG OH 44087
Re: K053258
Trade Name: EUB-6500 Diagnostic Ultrasound Scanner
Regulation Number: 21 CFR 892.1550
Regulation Name: Ultrasonic pulsed doppler imaging system
Regulation Number: 21 CFR 892.1560
Regulatory Name: Ultrasonic pulsed echo imaging system
Regulatory Number: 21 CFR 892.1570
Regulatory Name: Diagnostic ultrasonic transducer
Regulatory Class: II
Product Code: IYN, IYO, and ITX
Dated: November 14, 2005
Received: November 22, 2005
Dear Mr. Thistlewaite:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
This determination of substantial equivalence applies to the following transducers intended for use with the EUB-6500 Diagnostic Ultrasound Scanner, as described in your premarket notification:
Transducer Model Number
EUP-B514
EUP-C312T
EUP-C314G
EUP-C511
{2}
Page 2 – Mr. Thistlethwaite
| EUP-C516 | EUP-L65 |
| --- | --- |
| EUP-C524 | EUP-O53T |
| EUP-C532 | EUP-R54A-19 |
| EUP-C531 | EUP-R54A-33 |
| EUP-CV524 | EUP-R54AW-19 |
| EUP-F334 | EUP-R54AW-33 |
| EUP-L34T | EUP-S50 |
| EUP-L52 | EUP-S50A |
| EUP-L53 | EUP-S52 |
| EUP-L53L | Fujinon SP711 |
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA’s issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act’s requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This determination of substantial equivalence is granted on the condition that prior to shipping the first device, you submit a postclearance special report. This report should contain complete information, including acoustic output measurements based on production line devices, requested in Appendix G, (enclosed) of the Center’s September 30, 1997 “Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers.” If the special report is incomplete or contains unacceptable values (e.g., acoustic output greater than approved levels), then the 510(k) clearance may not apply to the production units which as a result may be considered adulterated or misbranded.
The special report should reference the manufacturer’s 510(k) number. It should be clearly and prominently marked “ADD-TO-FILE” and should be submitted in duplicate to:
Food and Drug Administration
Center for Devices and Radiological Health
Document Mail Center (HFZ-401)
9200 Corporate Boulevard
Rockville, Maryland 20850
This letter will allow you to begin marketing your device as described in your premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus permits your device to proceed to market.
{3}
Page 2 – Mr. Thistlethwaite
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html
If you have any questions regarding the content of this letter, please contact Rodrigo C. Perez at (301) 594-1212.
Sincerely yours,
Nancy C. Brogdon
Director, Division of Reproductive, Abdominal and Radiological Devices
Office of Device Evaluation
Center for Devices and Radiological Health
Enclosure(s)
{4}
DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | P | P | P | P | P | P | P |
| | Abdominal | Pa | Pa | Pa | Pa | Pa | Pa | Pa |
| | Intra-operative (Spec.) | Pb | Pb | Pb | | Pb | Pb | Pb |
| | Intra-operative (Neuro.) | P | P | P | | P | P | P |
| | Laparoscopic | P | P | P | | P | P | P |
| | Pediatric | P | P | P | P | P | P | P |
| | Small Organ (Spec.) | Pd | Pd | Pd | | Pd | Pd | Pd |
| | Neonatal Cephalic | P | P | P | | P | P | P |
| | Adult Cephalic | P | P | P | P | P | P | P |
| | Trans-rectal | Ph | Ph | Ph | | Ph | Ph | Ph |
| | Trans-vaginal | Pf | Pf | Pf | | Pf | Pf | Pf |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | P | P | P | | P | P | P |
| | Musculo-skel. (Superfic.) | P | P | P | | P | P | P |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | P | P | P | P | P | P | P |
| | Cardiac Pediatric | P | P | P | P | P | P | P |
| | Trans-esophageal (card.) | Pg | Pg | Pg | | Pg | Pg | Pg |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | P | P | P | P | P | P | P |
| | Other (spec.) | | | | | | | |
P = Previously Cleared, K013723
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging and 3D Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
Prescription Use
{5}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-8514
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division of Reproductive, Abdominal, ENT, and Radiological Devices)
510(k) Number: K053258
Prescription Use
{6}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C312T
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Vancey Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
Prescription Use
{7}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C314G
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging and 3D Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: 12053258
Prescription Use
{8}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C511
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | E | E | E | | E | E | E |
| | Cardiac Pediatric | E | E | E | | E | E | E |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
Prescription Use
{9}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C516
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053208
{10}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C524
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | E | E | E | | E | E | E |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | E | E | E | | E | E | E |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging and 3D Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

510(k) Number: K053258
{11}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-C532
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | Eb | Eb | Eb | | Eb | Eb | Eb |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | E | E | E | | E | E | E |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Davon B. B. (Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{12}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-CC531
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | | E | E | E |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | Ee | Ee | Ee | | Ee | Ee | Ee |
| | Trans-vaginal | Ef | Ef | Ef | | Ef | Ef | Ef |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{13}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-CV524
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | N | N | N | N | N | N | N |
| | Abdominal | N | N | N | N | N | N | N |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | N | N | N | N | N | N | N |
| | Small Organ (Spec.) | N | N | N | N | N | N | N |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
N = new indication.
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging and 3D Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy Chroydon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{14}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-F334
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | Eb | Eb | Eb | | Eb | Eb | Eb |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ec | Ec | Ec | | Ec | Ec | Ec |
| | Neonatal Cephalic | E | E | E | | E | E | E |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | E | E | E | | E | E | E |
| | Trans-vaginal | E | E | E | | E | E | E |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{15}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-L34T
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | E | E | E | | E | E | E |
| | Musculo-skel. (Superfic.) | E | E | E | | E | E | E |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy Bogdon
(Division Sign-Out)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{16}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-L52
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | E | E | E | | E | E | E |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Daviey C. Bogdon
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{17}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB·6500
Transducer: EUP·L53
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | Ea | Ea | Ea | | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ed | Ed | Ed | | Ed | Ed | Ed |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | E | E | E | | E | E | E |
| | Musculo-skel. (Superfic.) | E | E | E | | E | E | E |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging and 3D Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{18}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-L53L
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | E | E | E | | E | E | E |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ec | Ec | Ec | | Ec | Ec | Ec |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | E | E | E | | E | E | E |
| | Musculo-skel. (Superfic.) | E | E | E | | E | E | E |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{19}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-L65
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | E | E | E | | E | E | E |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | | E | E | E |
| | Small Organ (Spec.) | Ec | Ec | Ec | | Ec | Ec | Ec |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | E | E | E | | E | E | E |
| | Musculo-skel. (Superfic.) | E | E | E | | E | E | E |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{20}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-O53T
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | Eb | Eb | Eb | | Eb | Eb | Eb |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Dincerely Brogdon
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{21}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-R54A-19
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | E | E | E | | E | E | E |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{22}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-R54A-33
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | E | E | E | | E | E | E |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy Choudhry
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{23}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-R54AW-19
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | E | E | E | | E | E | E |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Brogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{24}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-R54AW-33
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | E | E | E | | E | E | E |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: 1053258
{25}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-S50
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | E | E | E | E |
| | Abdominal | Ea | Ea | Ea | Ea | Ea | Ea | Ea |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | E | E | E | E |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | E | E | E | E | E | E | E |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| | Other (spec.) | | | | | | | |
| Cardiac | Cardiac Adult | E | E | E | E | E | E | E |
| | Cardiac Pediatric | E | E | E | E | E | E | E |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | E | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy Hogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: R053258
{26}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-S50A
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | E | E | E | E | E | E | E |
| | Abdominal | E | E | E | E | E | E | E |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | E | E | E | E |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | E | E | E | E | E | E | E |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | E | E | E | E | E | E | E |
| | Cardiac Pediatric | E | E | E | E | E | E | E |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | E | E | E | E | E | E | E |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Hogdon
(Division Sign-Off)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K05-3258
{27}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: EUP-S52
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | E | E | E | E | E | E | E |
| | Small Organ (Spec.) | Ec | Ec | Ec | Ec | Ec | Ec | Ec |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | E | E | E | E | E | E | E |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Nancy C. Bogdon
(Division Sign-OD)
Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258
{28}
# DIAGNOSTIC ULTRASOUND INDICATIONS FOR USE FORM
System: EUB-6500
Transducer: Fujinon SP711
Intended use: Diagnostic ultrasound imaging or fluid flow analysis if the human body as follows:
| Clinical Application | | Mode of Operation | | | | | | |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| General (Track I only) | Specific (Tracks I & III) | B | M | PWD | CWD | Color Doppler | Combined* (Spec.) | Other** (Spec.) |
| Ophthalmic | Ophthalmic | | | | | | | |
| Fetal Imaging & Other | Fetal | | | | | | | |
| | Abdominal | | | | | | | |
| | Intra-operative (Spec.) | | | | | | | |
| | Intra-operative (Neuro.) | | | | | | | |
| | Laparoscopic | | | | | | | |
| | Pediatric | | | | | | | |
| | Small Organ (Spec.) | | | | | | | |
| | Neonatal Cephalic | | | | | | | |
| | Adult Cephalic | | | | | | | |
| | Trans-rectal | | | | | | | |
| | Trans-vaginal | | | | | | | |
| | Trans-urethral | | | | | | | |
| | Trans-esoph. (non-Card.) | | | | | | | |
| | Musculo-skel. (Convent.) | | | | | | | |
| | Musculo-skel. (Superfic.) | | | | | | | |
| | Intra-luminal | E | | | | | | |
| Other (spec.) | | | | | | | | |
| Cardiac | Cardiac Adult | | | | | | | |
| | Cardiac Pediatric | | | | | | | |
| | Trans-esophageal (card.) | | | | | | | |
| | Other (spec.) | | | | | | | |
| Peripheral Vessel | Peripheral vessel | | | | | | | |
| | Other (spec.) | | | | | | | |
E = Added under Appendix E
*Combination of each operating mode, B, M, PWD, CWD and Color Doppler.
**Amplitude Doppler, Harmonic Imaging.
Additional Comments:
| Subscript "a": | Includes imaging for guidance of percutaneous biopsy of abdominal organs and structures (including amniocentesis). |
| --- | --- |
| Subscript "b": | Includes imaging of organs and structures exposed during surgery (excluding neurosurgery and laparoscopic procedures). |
| Subscript "c": | Includes thyroid, parathyroid, breast, scrotum, penis. |
| Subscript "d": | Includes thyroid, parathyroid, breast, scrotum, penis and imaging for guidance of biopsy. |
| Subscript "e": | Includes imaging for guidance of transrectal biopsy. |
| Subscript "f": | Includes imaging for guidance of transvaginal biopsy. |
| Subscript "g": | For pediatric patients. |
| Subscript "h": | Includes imaging for guidance of transrectal biopsy. |
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)

Division of Reproductive, Abdominal, ENT, and Radiological Devices
510(k) Number: K053258