DIGITAL IMAGE ACQUISITION SYSTEM TO BE USED IN CONJUCTION WITH AN IMAGE INTESIFIER DURING RADIOGRAPHY OR FLUOROSCOPY X-RAY EXAMINATION TO CAPTURE IMAGES BY A CAMERA, DIGITALIZE THE IMAGE, REVIEW IMAGES AND FORMAT IMAGES ACCORDING TO DICOM PROTOCOL TO BE SENT THROUGH NETWORK CONNECTION
Device Story
NDR+/DIVA-D is a digital image acquisition system used with X-ray image intensifiers during radiography or fluoroscopy. It utilizes a 1024x1024 12-bit CCD camera to capture X-ray signals, which are then digitized and processed. The system features real-time hardware-based edge enhancement and a dynamic recursive filter for noise reduction. It supports Digital Subtraction Angiography (DSA) functions including mask subtraction, road mapping, and pixel shifting. Images are stored locally (up to 36,000 frames) and can be reviewed, annotated, and windowed by clinicians. The system formats images according to DICOM 3.0 for network transmission or output to a laser printer. Operated by clinical staff in radiology or interventional settings, the device replaces conventional film techniques, allowing for enhanced visualization of diagnostic details and improved workflow through digital storage and connectivity.
Indicated for use in conjunction with an image intensifier during radiography or fluoroscopy X-ray examinations to capture, digitize, review, and format images for DICOM network transmission.
Regulatory Classification
Identification
A stationary x-ray system is a permanently installed diagnostic system intended to generate and control x-rays for examination of various anatomical regions. This generic type of device may include signal analysis and display equipment, patient and equipment supports, component parts, and accessories.
Special Controls
*Classification.* Class II (special controls). A radiographic contrast tray or radiology diagnostic kit intended for use with a stationary x-ray system only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows a 3D rendering of the word "NICE!" in block letters. The letters are white and stand out against a dark background. The perspective is slightly angled, giving a sense of depth to the image. The word is set on a rectangular base, which adds to the three-dimensional effect.
K053029
JAN 6 2006
### Attachment 1 - 510 (k) SUMMARY
# 510(k) summary for NDR+- DIVA-D
#### Identification
| Applicant | NICAL SPA<br>43 Via Soffredini<br>Milan (MI), ITALY 20126<br>Registration Number: 3003314115 |
|-------------------------------|-------------------------------------------------------------------------------------------------|
| Contact Person | Mr. Roberto Niccolucci - President |
| Telephone (applicant) | +39 022571110 |
| Designated Agent<br>in the US | Mr. Gerald Silverman<br>71 Rose Street<br>Hasting On Hudson, NY 10706<br>Phone: +1 914 674 1085 |
| Manufacturing site | NICAL SPA<br>43 Via Soffredini<br>Milan (MI), ITALY 20126<br>Registration Number: 3003314115 |
#### Trade name: NDR+/DIVA-D
Common name: Digital image acquisition system Classification:
The equipment is classified as a class II
CFR21- 892.2050: Picture archiving and communication system
CFR21 - 892.1650: Image Intensified Fluoroscopic X-ray system.
Substantial equivalent device: the NDR+/DIVA-D is defined as Substantially Equivalent (SE) to the INFIMED Platinum ONE digital image acquisition system (certified under the name ORION) (K012490).
The following table compares the NDR+/DIVA-D and the predicate device
{1}------------------------------------------------
Image /page/1/Picture/0 description: The image shows a 3D rendering of the word "NIETL" in block letters. The letters are white and stand out against a dark background. The perspective suggests a slightly elevated viewpoint, giving a sense of depth to the image.
1
| FEATURES | NICAL (NDR+/DIVA D) | INFIMED (Platinum ONE) |
|----------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Intended use | The NICAL NDR+ is a digital image<br>acquisition system to be used in<br>conjunction with an image Intensifier<br>during radiography or fluoroscopy x-<br>ray examination to capture images by<br>a camera, digitalize the image, review<br>images and format images according<br>to DICOM 3.0 protocol to be sent<br>through network connection | The INFIMED Orion Fluoroscopic<br>imaging system is a high resolution,<br>digital imaging system designed for<br>digital videography. It is intended to<br>replace conventional film techniques<br>in multipurpose or dedicated<br>applications where general<br>fluoroscopy, interventional<br>fluoroscopy or angiography or<br>cardiac imaging procedures are<br>performed.<br>The Orion system allows the<br>operator to view and enhance 1000<br>line fluoroscopy. High resolution<br>digital spot images ( 1024x1024)<br>may be acquired at single or rapid<br>acquisition rates. Images may be<br>viewed and enhanced enabling the<br>operator to bring out diagnostic<br>details difficult or impossible to see<br>using conventional imaging<br>techniques.<br>The Orion system enables the<br>operator to hardcopy image with a<br>laser printer or send images over a<br>network. The major system<br>components include: a fluoroscopic<br>TV camera, monitors, and an image<br>processor. · |
| Image Acquisition | CCD camera 1024x1024 12 bit | CCD camera 1024x1024 12 bit |
| Speed Acquisition | 1024x1024 at 25 fps for FLUORO and<br>all radiographic exams | Up to 30 fps for FLUORO<br>acquisition and up to 15 fps for spot<br>acquisition |
| Edge Enhancer | Completely hardware in real time | Software package |
| Start Up System | Automatic hardware and software test<br>for each ignition | Automatic system calibration and<br>remote system diagnostics |
| Noise Reduction | Dynamic recursive filter which<br>offering an automatic noise/blurring<br>optimization effect it gives zero<br>persistence | Standard recursive filter |
| Image Storage | Up to 36000 frames with matrix<br>1024x1024.<br>All the images are stored directly from<br>the CCD camera head without any<br>kind of edge enhancement and digital<br>compression. | NA |
| Post Processing<br>Working | All the images stored in the system can<br>be elaborated in order to modify the<br>windowing, the gray scale, the zoom,<br>the annotation package, the edge<br>enhancement and the noise reduction | Brightness/contrast polarity<br>enhancement. Measurement and<br>annotation package |
| DSA Application | Real time mask subtraction, road<br>mapping, land marking, pixel shift<br>function, auto loop replay, injector<br>synchronization, automatic or manual<br>possibility to change the mask, maxop<br>function and stepping angio | Real time mask subtraction, road<br>mapping, land marking, percent<br>Stenosis vascular package, auto loop<br>replay, injector synchronization. |
| Multi Image | Thumbnail image viewing with the<br>possibility to choose the first image for<br>every run or the 50% of the run. | Thumbnail image viewing |
| DICOM Functions | Full DICOM 3.0 integrated | Full DICOM 3.0 integrated |
| Laser Interface | When DICOM network is not<br>available in the site installation, it is<br>possible to send the images to a laser<br>printer using the protocol P831 or<br>P859 | NA |
| Interface Commands | Flat keyboard with waterproof surface | Standard pc keyboard + standard pc<br>mouse |
510(K) Summary for NDR+/DIVA-D
{2}------------------------------------------------
Image /page/2/Picture/0 description: The image shows a logo with the letters "NICA" in a stylized, three-dimensional font. The letters are slanted and appear to be embossed or raised from a dark, solid background that is shaped like a geographical region. The logo has a simple, bold design and is likely associated with an organization or entity named NICA.
#### Indication for use.
The indication for use of the NDR+/DIVA-D is: DIGITAL IMAGE ACQUISITION SYSTEM TO BE USED IN CONJUCTION WITH AN IMAGE INTESIFIER DURING RADIOGRAPHY OR FLUOROSCOPY X-RAY EXAMINATION TO CAPTURE IMAGES BY A CAMERA, DIGITALIZE THE IMAGE, REVIEW IMAGES AND FORMAT IMAGES ACCORDING TO DICOM PROTOCOL TO BE SENT THROUGH NETWORK CONNECTION
{3}------------------------------------------------
Image /page/3/Picture/0 description: The image shows the logo for the Department of Health & Human Services. The logo includes the department's name in blue text. To the left of the text is a circular emblem with a stylized image of a human figure.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room - WO66-G609 Silver Spring, MD 20993-0002
NICAL SPA % Mr. Gerald Silverman Designated Agent 71 Rose Street Hasting on Hudson, NY 10706
AUG 2 3 2013
Re: K053029
Trade/Device Name: NDR+/DIVA-D Regulation Number: 21 CFR 892.1680 Regulation Name: Stationary x-ray system Regulatory Class: II Product Code: MQB Dated: October 27, 2005 Received: November 25, 2005
Dear Mr. Silverman:
This letter corrects our substantially equivalent letter of January 6, 2006.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into class II (Special Controls), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition. FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Parts 801 and 809): medical device reporting of
{4}------------------------------------------------
medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely Yours,
Janine M. Morris
Janine M. Morri Acting Director Division of Radiological Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows a black and white picture of a structure with the word "NIECO" on it. The structure appears to be made of concrete or stone. The word "NIECO" is written in large, bold letters across the front of the structure. The image is a low-resolution image.
## 6.1. Indication for use Statement
510(k) Number: Kos 30 2 7
Device Name: NDR+ or DIVA-D
The indication for use of the NDR+/DIVA-D is: DIGITAL IMAGE ACQUISITION SYSTEM TO BE USED IN CONJUCTION WITH AN IMAGE RADIOGRAPHY INTESIFIER DURING OR FLUOROSCOPY X-RAY EXAMINATION TO CAPTURE IMAGES BY A CAMERA, DIGITALIZE THE IMAGE, REVIEW IMAGES AND FORMAT IMAGES ACCORDING TO DICOM PROTOCOL TO BE SENT THROUGH NETWORK CONNECTION
Daniel A. Lysom
Division Sign-Off ivision of Reproductive. Abdominal nd Radiological Devic
Prescription Use
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.