MYTIS ARROW XXXX
Device Facts
| Record ID | K052254 |
|---|---|
| Device Name | MYTIS ARROW XXXX |
| Applicant | Brainbase Corporation |
| Product Code | DZE · Dental |
| Decision Date | Jun 1, 2006 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Mytis Implant Systems are intended for immediate placement in partially or fully edentulous mandibles and maxillae (type 1 or II bone), in support of single or multiple-unit restorations including, cement retained, screw retained, or over-denture restorations, and terminal or intermediate abutment support for fixed bridgework.
Device Story
Mytis Arrow Implant System consists of root-form endosseous dental implants and compatible abutments. Designed for dental implant surgery; used in single or two-stage surgical procedures. Implants integrate with bone to support dental restorations. Used by dental professionals in clinical settings. Provides structural foundation for cement-retained, screw-retained, or over-denture restorations and fixed bridgework. Benefits patients by restoring oral function and aesthetics in edentulous sites.
Clinical Evidence
No clinical data provided; substantial equivalence based on design and technological characteristics.
Technological Characteristics
Root-form endosseous dental implants and abutments. Designed for osseointegration. Materials and dimensions consistent with standard dental implant systems. No software or electronic components.
Indications for Use
Indicated for patients with partially or fully edentulous mandibles and maxillae (type 1 or II bone) requiring single or multiple-unit restorations, including cement-retained, screw-retained, or over-denture restorations, and terminal or intermediate abutment support for fixed bridgework.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Predicate Devices
- Branemark Implants (K022562)
- Branemark Implants (K993595)
- 3i Dental Implant Systems (K022113)
- 3i Dental Implant Systems (K022009)