K051568 · Smiths Medical MD, Inc. · FRN · Nov 17, 2005 · General Hospital
Device Facts
Record ID
K051568
Device Name
CADD-MS 3 AMBULATORY INFUSION PUMP
Applicant
Smiths Medical MD, Inc.
Product Code
FRN · General Hospital
Decision Date
Nov 17, 2005
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 880.5725
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The CADD-MS™ 3 Ambulatory Infusion Pump is designed for subcutaneous, intravenous, epidural and intrathecal infusion of medication. The Smiths Medical MD, Inc. 3-ml Cartridge Reservoir is designed for use with the CADD-MS™ 3 for delivering medication.
Device Story
Microprocessor-based electronic syringe pump; 3-ml cartridge reservoir; delivers medication via subcutaneous, intravenous, epidural, or intrathecal routes. User programs basal (continuous), bolus (demand), and automatic dosing profiles via front keypad and LCD based on internal real-time clock. Features include cartridge sensor, downstream occlusion sensor, audible/vibratory alarms, and waterproof housing. Powered by one AAA battery. Used in ambulatory settings; operated by clinicians or patients. Output provides controlled medication delivery; assists in managing infusion therapy; enables precise low-volume dosing.
Clinical Evidence
No clinical data. Safety and effectiveness established through bench testing, including software validation, verification of programming functions, and biocompatibility testing of the 3-ml cartridge.
Indicated for subcutaneous, intravenous, epidural, and intrathecal infusion of medication in patients requiring low-volume syringe-based therapy.
Regulatory Classification
Identification
An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.
Predicate Devices
CADD-Micro® Ambulatory Infusion Pump
Submission Summary (Full Text)
{0}------------------------------------------------
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS CADD-MSTM 3 Ambulatory Infusion Pump June 13, 2005 K051568
### GENERAL INFORMATION
# NOV 1 7 2005
| Applicant's Name and Address: | Smiths Medical MD, Inc.<br>1265 Grey Fox Road<br>St. Paul, MN 55112 |
|--------------------------------|---------------------------------------------------------------------|
| Contact Person: | Melanie Hess<br>Regulatory and Clinical Affairs Associate |
| Common/Usual Name: | Ambulatory Syringe Pump |
| Proprietary Name: | CADD-MS™ 3 Ambulatory Infusion Pump |
| Equivalence Device Comparison: | CADD-Micro® Ambulatory Infusion Pump |
#### II. DEVICE DESCRIPTION
The Smiths Medical MD, Inc. CADD-MS™ 3 Ambulatory Infusion Pump, a microprocessor based electronic syringe pump with a 3-ml cartridge reservoir, is designed for low volume syringe-based infusion therapy allowing continuous, automatic dose and demand dose delivery profiles for subcutaneous, intravenous, epidural and intrathecal delivery.
The pump operates on one (1) AAA alkaline battery. The user-interface of hardware features include a backlit liquid crystal display, 4-key front keypad, separate bolus button, audible or vibratory alarm, battery cap and cartridge cap. The pump is waterproof and features a cartridge sensor and downstream occlusion sensor.
Based on user code-entry and an internal real-time clock, a user will be able to program multiple basal (continuous), bolus (demand) dosing and automatic dosing delivery profiles within programmed maximum limits.
The pump accommodates the Smiths Medical MD, Inc. 3ml cartridge reservoir.
{1}------------------------------------------------
### 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS CADD-MS™ 3 Ambulatory Infusion Pump
June 13, 2005
# KOS1568
#### INTENDED USE OF THE DEVICE III.
The CADD-MS™ 3 is a syringe infusion pump designed for subcutaneous, intravenous, intrathecal and epidural delivery of medication.
The Smiths Medical MD, Inc. 3ml Cartridge is designed for use with the CADD-MS™ 3 for delivering medication
#### IV. DEVICE COMPARISON
The CADD-MS™ 3 Ambulatory Infusion Pump was compared to and found to be substantially equivalent to the following commercially available predicate device: CADD-Micro® Ambulatory Infusion Pump.
The CADD-MS™ 3 Ambulatory Infusion Pump is substantially equivalent to the CADD-Micro Ambulatory Infusion Pump with respect to indications for use and performance features
#### V. SUMMARY OF STUDIES
### A. Functional Testing
Test plans associated with software validation, verification of software controlled programming functions, and software related to proper pump operation were performed.
Biocompatibility testing for the 3-ml Cartridge was performed and found to be biocompatible
### B. Clinical Studies
Human clinical studies were not deemed necessary to evaluate the safety or effectiveness of the CADD-MS™ 3 Ambulatory Infusion Pump.
### C. Conclusions Drawn from the Studies
Based upon the information provided through verification and validation test reports, the CADD-MS™ 3 Ambulatory Infusion Pump is safe, effective and performs to established specifications.
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image is a black and white circular logo. The logo features a stylized image of an eagle with three wing segments. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the top half of the circle. The text is in a sans-serif font and is oriented to follow the curve of the circle.
Public Health Service
NOV 1 7 2005
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Ms. Melanie Hess Regulatory and Clinical Affairs Associate Smith Medical MD, Incorporated 1265 Grev Fox Road St. Paul. Minnesota 55112
Re: K051568
Trade/Device Name: CADD-MS™ 3 Ambulatory Infusion Pump Regulation Number: 21 CFR 880.5725 Regulation Name: Infusion Pump Regulatory Class: II Product Code: FRN Dated: October 31, 2005 Received: November 1, 2005
Dear Ms. Hess:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{3}------------------------------------------------
Page 2 - Ms. Hess
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours,
Smette y. Michin ons.
Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Smiths Medical MD, Inc. Indications for Use Statement 510(k) Number: K051568
# Device Name: CADD-MS'" 3 Ambulatory Infusion Pump
Indications for Use:
"The CADD-MS™ 3 Ambulatory Infusion Pump is designed for subcutaneous, intravenous, epidural and intrathecal infusion of medication."
Prescription Use x 21 CFR 801.109)
OR
OR
Over-The Counter Use Per
### Device Name: Smiths Medical MD, Inc. 3-ml Cartridge Reservoir
Indications for Use:
"The Smiths Medical MD, Inc. 3-ml Cartridge Reservoir is designed for use with the CADD-MS™ 3 for delivering medication."
Prescription Use _____________________________________________________________________________________________________________________________________________________________ 21 CFR 801 109)
Over-The Counter Use -------Per
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Anton Wang
Siston (Sign-Off) Division of Anesthesiology, General Hospital, Intection Control, Dental Devices
510(k) Number. k051568
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.