E-TYPE STRAIGHT HANDPIECE, MODEL AHP-101

K051077 · Aseptico, Inc. · EGS · May 3, 2005 · Dental

Device Facts

Record IDK051077
Device NameE-TYPE STRAIGHT HANDPIECE, MODEL AHP-101
ApplicantAseptico, Inc.
Product CodeEGS · Dental
Decision DateMay 3, 2005
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.4200
Device ClassClass 1
AttributesTherapeutic, 3rd-Party Reviewed

Indications for Use

The AHP-101 fully autoclavable, straight, 1:1 ratio E-Type dental handpiece is intended for use in general dentistry procedures, such as removing carious material from the dentine.

Device Story

AHP-101 is a straight, 1:1 ratio E-Type dental handpiece; accepts standard 2.35mm (3/32") burs; compatible with prophy angles. Used in general dentistry for procedures like caries removal. Operated by dental professionals in clinical settings. Connects to standard E-type dental handpiece motors. Device is fully autoclavable to ensure sterility. Provides mechanical rotation to dental burs for tooth preparation and cleaning.

Clinical Evidence

Bench testing only. Device validated for sterility assurance level (SAL) of 10^-6 and compliance with ISO 7785-2, ISO 3964, ISO 11134, and AAMI TIR No. 12-1994 standards.

Technological Characteristics

Straight, 1:1 gear-ratio E-Type handpiece. Materials: stainless steel, brass, anodized aluminum. Input speed: 0-30,000 RPM. Compatibility: 2.35mm (3/32") burs. Sterilization: fully autoclavable. Standards: ISO 7785-2:1995, ISO 3964:1982, ISO 11134:1994, AAMI TIR No. 12-1994.

Indications for Use

Indicated for general dentistry procedures, including removal of carious material from dentine, in patients requiring dental intervention.

Regulatory Classification

Identification

A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or belt-driven, hand-held device that may include a foot controller for regulation of speed and direction of rotation or a contra-angle attachment for difficult to reach areas intended to prepare dental cavities for restorations, such as fillings, and for cleaning teeth.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ - 3 2005 MAY Image /page/0/Picture/2 description: The image shows a logo for "ASEPTICO International". The logo is in a stylized font, with the word "ASEPTICO" in a larger font size than the word "International". The logo is in black and white, and the text is slightly distorted. Aseptico Inc. · 8333 216" St SE · Woodinville, WA 98072 Telephone: (425) 487-3157 Fax: (360) 668-8722 Web: www.aseptico.com E-mail: grant(@aseptico.com ## 510(k) Summary Contact: Grant Ramaley Date Prepared: April 11, 2005 Trade or Proprietary Name: AHP-101 E-Type Straight Handpiece Classification Name: 872.4200 Dental Handpiece and Accessories 510(k) Number: ### Device Description: The AHP-101 is a straight, fully autoclavable, 1:1 ratio E-Type dental handpiece intended for use in general dentistry procedures. It accepts standard 2.35mm (3/32") burs and may be used with prophy angles. ### Features of Substantial Equivalence to Aseptico's AHP-64 Handpiece [510(k) K020137] - Intended for general dentistry procedures 1) - Fits all E-type dental handpiece motors 2) - Fully autoclavable. Independently validated sterility assurance level (SAL) of10° 3) - Straight, 1:1 gear-ratio design 4) - 5) 0 30,000 RPM input speed range - 6) Constructed of stainless steel, brass, and anodized aluminum - 7) Complies with applicable portions of the following standards: ISO 7785-2:1995, ISO 3964:1982, ISO 11134:1994, AAMI TIR No. 12-1994 {1}------------------------------------------------ Image /page/1/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS) of the United States. The seal features the department's name in a circular arrangement around a stylized emblem. The emblem consists of a stylized caduceus, a symbol often associated with medicine and healthcare, with three parallel lines representing the branches of government. Image /page/1/Picture/3 description: The image shows a date, "MAY - 3 2005". The month is MAY, the day is 3, and the year is 2005. The text is in a simple, sans-serif font and is easy to read. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Aseptico, Incorporated C/O Mr. Daniel W. Lehtonen Responsible Third Party Official Intertek Testing Services NA, Incorporated 70 Codman Hill Road Boxborough, Massachusetts 01719 Re: K051077 Trade/Device Name: AHP-101 E-Type Straight Handpiece Regulation Number: 872.4200 Regulation Name: Dental Handpiece and Accessories Regulatory Class: I Product Code: EGS Dated: April 25, 2005 Received: April 27, 2005 Dear Mr. Lehtonen: We have reviewed your Section 510(k) premarket notification of intent to market the device we nated above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general approvisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting (1 Wri), It may of bagges in the Code of Federal Regulations, Title 21, Parts 800 to 898. In your device of the read may publish further announcements concerning your device in the Federal Register {2}------------------------------------------------ ### Page 2 - Mr. Lehtonen Please be advised that FDA's issuance of a substantial equivalence determination does not I lease to advised that 12 a determination that your device complies with other requirements mount that I Drima mires and regulations administered by other Federal agencies. or the rice of any - outh all the Act's requirements, including, but not limited to: registration 1 ou intist comply with a807); labeling (21 CFR Part 801); good manufacturing practice and fisting (2) 22 x 1 forth in the quality systems (QS) regulation (21 CFR Part 820); and if requirements as betronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) This letter will and in you The FDA finding of substantial equivalence of your device to a premaired predicated. 22 device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), rr you desire spocitiv at . of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Jenette G. Michie Oms. Chiu Lin. Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ # Indications for Use 510(k) Number (if known): KSS1077 Device Name: _AHP-101 E-Type Straight Handpiece_ Indications for Use: The AHP-101 fully autoclavable, straight, 1:1 ratio E-Type dental handpiece is THE Arlin "To Fraily datestal dentistry procedures, such as removing carious material from the dentine. Prescription Use _____________________________________________________________________________________________________________________________________________________________ (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Kein Mulvey for MSR on of Anesthesiology, General Hospital, ection Control, Dental Devices Number. K051017
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...