K050630 · Boston Scientific - Precision Vascular · KRA · Mar 22, 2005 · Cardiovascular
Device Facts
Record ID
K050630
Device Name
PIVOT STEERABLE MICROCATHETER
Applicant
Boston Scientific - Precision Vascular
Product Code
KRA · Cardiovascular
Decision Date
Mar 22, 2005
Decision
SESE
Submission Type
Special
Regulation
21 CFR 870.1210
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The "PivotTM" Steerable Microcatheter is intended to be used to access tortuous vasculature for sub-selective controlled infusion or delivery of diagnostic, embolic, and therapeutic agents into the distal, peripheral, coronary, and neurovasculature, and for guide wire exchange/support during diagnostic or interventional procedures.
Device Story
Pivot Steerable Microcatheter: 1.9F/2.4F tubular device (~150 cm); lumen for delivery of contrast, drugs, or embolics; lubricious coating on distal segment; two radiopaque markers at distal tip for fluoroscopic visualization; standard luer adapter at proximal end. Used by physicians to access distal, tortuous vasculature over guide wire; steerable like guide wire. Enables sub-selective infusion/delivery of agents; provides guide wire support. Benefits patient by facilitating access to complex vascular anatomy for diagnostic or interventional procedures.
Clinical Evidence
Bench testing only. Verification included dimensional inspection, hub integrity, flow rate, burst strength, tensile strength, guidewire compatibility, torsional strength, torqueability, and corrosion resistance per ISO 10555-1. All results acceptable.
Technological Characteristics
1.9F/2.4F tubular catheter; polymeric construction; hydrophilic coating; radiopaque markers; standard luer adapter. Tested per ISO 10555-1. Mechanical device; no software or energy source.
Indications for Use
Indicated for patients requiring access to tortuous vasculature for sub-selective controlled infusion or delivery of diagnostic, embolic, and therapeutic agents into distal, peripheral, coronary, and neurovasculature, and for guide wire exchange/support during diagnostic or interventional procedures.
Regulatory Classification
Identification
A continuous flush catheter is an attachment to a catheter-transducer system that permits continuous intravascular flushing at a slow infusion rate for the purpose of eliminating clotting, back-leakage, and waveform damping.
{0}------------------------------------------------
K050630
## Summary of Safety and Effectiveness
Prepared 8 March 2005
| General<br>Provisions | Submitter of 510(k)<br>Premarket Notification: | Boston Scientific - Precision Vascular<br>2405 West Orton Circle<br>West Valley City, UT 84119<br>Phone: 801.974.1700<br>Fax: 801.974.1740 | |
|--------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------|
| | Contact Person: | Rick Gaykowski<br>Vice President, Regulatory/Clinical<br>Affairs & Quality Systems | |
| | Device Trade Name: | "PivotTM" Steerable Microcatheter | |
| | Device Generic Name: | Infusion Catheter | |
| | The predicate devices are listed below. | | |
| Predicate<br>Devices | Device | Manufacturer | 510(k) Number/Date<br>Pro Code |
| | <i>SDS</i> 0.018" | PVS, Inc. | K020733, 21 March 2002<br>KRA |
| | <i>SDS</i> 0.010" | PVS, Inc. | K032494, 05 Sep 2003<br>KRA |
| | <i>Pivot</i> "SDS" | PVS, Inc. | K033726, 16 Jan 2004<br>KRA |
| Classification | Class II, 21 CFR 870.1210, Continuous Flush Catheter, KRA | | |
| Performance<br>Standards | Performance standards have not been established by FDA under section 514 of the<br>Federal Food, Drug and Cosmetic Act. | | |
| Intended Use | The "PivotTM" Steerable Microcatheter is intended to be used to access tortuous<br>vasculature for sub-selective controlled infusion or delivery of diagnostic, embolic, and<br>therapeutic agents into the distal, peripheral, coronary, and neurovasculature, and for<br>guide wire exchange/support during diagnostic or interventional procedures. | | |
| Device<br>Description | The "PivotTM" Steerable Microcatheter is a 1.9F/2.4F (nominal distal/proximal) tubular<br>device, ~150 cm in length, with a lumen to be used for delivery of contrast, drugs, or<br>embolics. The lumen is constructed from a polymeric material and has an inside<br>diameter of 0.017". The device is coated on the outer diameter with a lubricious<br>coating over the distal segment of the device. Two radiopaque markers are positioned<br>at the distal tip of the device to aid visualization under fluoroscopy. The proximal end of<br>the device has a standard luer adapter for attachment of accessories and can be used<br>to flush the lumen. The subject device has the ability to access distal, tortuous<br>vasculature over a guide wire, deliver embolics and agents, and has the ability to be<br>steered like a guide wire as needed. | | |
{1}------------------------------------------------
| Technological<br>Characteristics | Technological similarities between the "Pivot™" Steerable Microcatheter and predicate devices include the basal tubular design and dimensions, polymeric materials and construction, and hydrophilic coating. In instances where the technological characteristics may differ slightly, it has been demonstrated that there are no new questions raised regarding safety and efficacy of the "Pivot™" Steerable Microcatheter. |
|------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Safety and<br>Performance<br>Tests | Performance testing of the "Pivot™" Steerable Microcatheter was conducted in accordance with ISO 10555-1, Sterile, Single-Use Intravascular Catheters -- Part 1. Verification testing for the subject device included dimensional inspection, hub integrity, flow rate measurements, burst strength, tensile strength, guidewire compatibility testing and performance under simulated conditions. Subject product testing has yielded acceptable results.<br>In addition, torsional strength, torqueability, and corrosion resistance tests have also yielded acceptable results. The results of these tests, in conjunction with the substantial equivalence claims as outlined in the premarket notification, effectively demonstrate the "Pivot™" Steerable Microcatheter is substantial equivalent to the cited predicate devices. |
| Summary of<br>Substantial<br>Equivalence | Based on the indications for use, technological characteristics, and safety and performance testing, the subject "Pivot™" Steerable Microcatheter meets the minimum requirements that are considered adequate for its intended use and is substantially equivalent in design, materials, sterilization, principles of operation and indications for use to current commercially available catheters/cited predicates. |
{2}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized symbol of three horizontal lines curving upwards, resembling a human figure with outstretched arms.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 2 2 2005
Mr. Rick Gaykowski Mice President, Regulatory/Clinical Affairs & Quality Systems Boston Scientific - Precision Vascular 2405 West Orton Circle West Valley City, UT 84119
K050630 Re:
Trade/Device Name: Pivor™ Steerable Microcatheter Regulation Number: 21 CFR 870.1210 Regulation Name: Continuous flush catheter Regulatory Class: II Product Code: KRA Dated: March 10, 2005 Received: March 11, 2005
Dear Mr. Gaykowski:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for assessment to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set
{3}------------------------------------------------
Page 2 – Mr. Rick Gaykowski
Fage 2 - "htt read as a proposion (21 CFR Part 820); and if applicable, the electronic
forth in the quality systems in and inco (Sections 531-542 of the Act); 21 CFR 1000-105 forth in the quality systems (QS) regulation (2) CFR Pat 620); and 11 CFF
product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. 101 - 12 - 12 - 12 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -This letter will allow you to begin marketing your device of your device to a legally
premarket notification. The FDA finding of subscification for your device to a legally remarket notification. The FDA finding of substantial on your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please
s and the results of the support (240) 276.0120 . Also, please note the r If you desire specific advice for your device on our labeling nease not the regulation entitled,
contact the Office of Compliance at (240) 276-0120. Also, please not 97). contact the Office of Compliance at (240) 270-01-20. Proxet 807.97). You may obtain
"Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obta "Misbranding by reference to premarket notification "(21 cf 1 cr from the Division of Small
other general information on your responsibilities under the Act from the Division other general information on your responsibilities under (800) 638-204) or 2001)
Manufacturers, International and Consumer Assistance at its todalfred wordindex.html. Manufacturers, International and Consumer Assistance at les to restor in over index.html.
(301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/i
Sincerely yours,
Durna R. Kirchner
Bram D. Zuckerman, M.D.
Director
Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Page 1 of 1
510(k) Number (if known): ¥650630_
Device Name: "Pivot™" Steerable Microcatheter
Indications for Use:
The "Pivot™" Steerable Microcatheter is intended to be used to access tortuous vasculature for sub-The "Pivot™" Steerable Microcather is intended to activer and therapeutic agents into the distal,
selective controlled infusion of diagnosic, emblic, and therapeupport during selective controlled infusion or delivery of diagnostic, endonic, and therebels agence of the counter of the county, or interventional procedures.
:
. . .
PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NECESSARY
Concurrence of CDRH, Office of Device Evaluation (ODE)
| Prescription Use | <span></span> ✓ | OR | Over-the-Counter Use | |
|----------------------|-----------------|----|----------------------|--|
| (Per 21 CFR 801.109) | | | | |
| | <div style="text-align:left;">Donna P. Vechinel</div> <div style="text-align:left;">(Division Sign-Off)</div> <div style="text-align:left;">Division of Cardiovascular Devices</div> |
|---------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 510(k) Number | K050630 |
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.