← Product Code [GEX](/productcode/GEX) · K050382

# AFFINITY QS Q-SWITCHED ND:YAG LASER SYSTEM (K050382)

_Cynosure, Inc. · GEX · Sep 14, 2005 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda-staging.innolitics.com/device/K050382

## Device Facts

- **Applicant:** Cynosure, Inc.
- **Product Code:** [GEX](/productcode/GEX.md)
- **Decision Date:** Sep 14, 2005
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4810
- **Device Class:** Class 2
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

The Affinity QS laser is intended for treatment of vascular lesions, pigmented lesions, and for hair, tattoo removal, and the incision, excision, ablation, vaporization of soft tissue for general dermatology.

## Device Story

Affinity QS Q-Switched Nd:YAG laser system; provides 1064nm and 532nm wavelengths. Laser emission activated via foot switch. Used in clinical dermatology settings by trained professionals. Device transforms electrical energy into laser output for tissue interaction. Output used by clinicians to perform dermatological procedures including lesion treatment, hair/tattoo removal, and soft tissue surgery. Benefits include precise tissue ablation and removal of pigmented/vascular structures.

## Clinical Evidence

No clinical data provided; bench testing only.

## Technological Characteristics

Q-Switched, frequency-doubled Nd:YAG laser system. Wavelengths: 1064nm and 532nm. Electrical requirements: 230 VAC, 20A, 50-60 Hz, single phase. Dimensions: 25" x 15" x 78". Weight: 180 lbs. Foot switch activation.

## Regulatory Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

## Predicate Devices

- Medlite C6 Q-Switched Nd:YAG Laser system

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

## 510(K) : ummary

SEP 1 4 2005

| Submitter:                    | Cynosure, Inc.<br>10 Elizabeth Drive<br>Chelmsford, MA 01824                                                                                                                                                                                                                                                                                          |
|-------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact:                      | George Cho<br>Senior Vice President of Medical Technology                                                                                                                                                                                                                                                                                             |
| Date Summary Prepared:        | February 14, 2005                                                                                                                                                                                                                                                                                                                                     |
| Device Trade Name:            | Affinity QS Q-Switched Nd:YAG Laser system                                                                                                                                                                                                                                                                                                            |
| Common Name:                  | Q-Switched Nd:YAG laser                                                                                                                                                                                                                                                                                                                               |
| Classification Name:          | Instrument, surgical, powered, laser<br>79-GEX<br>21 CFR 878.48                                                                                                                                                                                                                                                                                       |
| Equivalent Device:            | Medlite C6 Q-Switched Nd:YAG Laser system                                                                                                                                                                                                                                                                                                             |
| Device Description:           | The Affinity QS Q-Switched Nd:YAG Laser is a Q-Switched,<br>frequency doubled laser system. It provides both 1064nm and 532nm<br>wavelengths.<br>Laser emission activation is by foot switch. Overall weight of the laser<br>is 180 lbs., and the size is 25" x 15" x 78" (LxWxH).<br>Electrical requirement is 230 VAC, 20A, 50-60 Hz, single phase. |
| Intended Use:                 | The Affinity QS laser is intended for treatment of vascular lesions,<br>pigmented lesions, and for hair, tattoo removal, and the incision,<br>excision, ablation, vaporization of soft tissue for general dermatology.                                                                                                                                |
| Comparison:                   | The Affinity QS laser system has identical indication for use, the same<br>principle of operation, and essentially the same wavelength range and<br>pulse energy range as the predicate device.                                                                                                                                                       |
| Nonclinical Performance Data: | none                                                                                                                                                                                                                                                                                                                                                  |
| Clinical Performance Data:    | none                                                                                                                                                                                                                                                                                                                                                  |
| Conclusion:                   | The Affinity QS laser is a safe and effective device for the treatment of<br>vascular and pigmented lesions, for hair and tattoo removal, and for<br>the incision, excision, ablation, vaporization of soft tissue for general<br>dermatology.                                                                                                        |
| Additional Information:       | none                                                                                                                                                                                                                                                                                                                                                  |

:

:

{1}------------------------------------------------

DEPARTMENT OF HEALTH & HUMAN SERVICES

Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES, USA" around the perimeter. Inside the circle is a stylized symbol that resembles a caduceus, a traditional symbol of medicine, but with three wavy lines instead of snakes.

Public Health Service

SEP 1 4 2005

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

Mr. George Cho Senior Vice President Medical Technoogy Cynosure Incorporated 10 Elizabeth Drive Chelmsford, Massachusetts 01824

Re: K050382 Trade/Device Name: Cynosure Affinity QS Laser Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: II Product Code: GEX Dated: August 31, 2005 Received: September 2, 2005

Dear Mr.Cho:

We have reviewed your Section 510(k) premarket notification of intent to market the device in We have reviewed your Section 9 rotty premained is substantially equivalent (for the indications referenced above and nave determined the actived predicate devices marketed in interstate for use stated in the encrosule for legally manatise to of the Medical Device American of Grod. Ford, Drug commerce prior to May 28, 1776, the enacting with the provisions of the Federal Food. Drug. devices that have been reclassified in acceraanse while has remarket approval application (PMA). and Cosment Act (Act) that to not require approvide controls provisions of the Act. The You may, therefore, market the device, belyer to the more
general controls provisions of the Act include requirements for annual registration, listing of general controls provisions of the Hecking, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it If your device is classified (see above) me existing major regulations affecting your device can may be subject to such additional controlls. Extrangemand on 898. In addition, FDA may be found in the Code of Peachar Regerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean Prease be advised that I Dri- 3 issuation or our device complies with other requirements of the Act that TDA has made a decorminations administered by other Federal agencies. You must of ally Federal statures and regulations adminited to: registration and listing (21 comply with an the Act 81equire Rart 801); good manufacturing practice requirements as set CFK Part 807), labeling (21 CFR Part 820); and If applicable, the electronic forth in the quality systems (Sections 531-542 of the Act); 21 CFR 1000-1050.

{2}------------------------------------------------

Page 2- Mr. George Cho

This letter will allow you to begin marketing your device as described in your Section 510(k) This letter will allow you to begin marketing your article quivalence of your device to a legally
premarket notification. The FDA finding of substantial end thus, permits vo premarket notification. The FDA Inding of substantial equice and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please
rs the latest of the many of the 1076 0115 . Algeralation entitled If you desire specific advice for your de not on on S. Also, please note the regulation entitled, the may obtain contact the Office of Compliance at (240) 270 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 - 1 "Misbranding by relerence to premarket notifiedavin (e. the Act from the Division of Small other general information on your responsion.com at its toll-free number (800) 638-2041 or
Manufacturers, International and Consumer Assistance at the Admanain html Manufacturers, International and Consulter Piersons. Passions of thinksma/dsmamain.html

Sincerely yours,

Aubrey Buchus

Mark N. Melkerson Acting Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{3}------------------------------------------------

510(k) Number (if known):

K050382

Device Name: _Cynosure Affinity QS Laser

Indications For Use:

The Affinity QS Laser is intended for the treat nent of vasular lesions, and for The Affinity QS Laser is intended for the treat of vascular resoluly plantined and of the for general dermatology.

> OR Prescriptive Use_ x (Part 21 CFR 801 Subpart D)

Over-The-Counter Use (Part 21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINF - CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, ( vffice of Device Evaluation (ODE)

Barbara Buell for MM

(Division Sign-O Division of General, Re and Neurological Devices

**510(k) Number** L050382

Image /page/3/Picture/12 description: The image shows the words "Prescription Use" with a line underneath the words. There is a check mark to the right of the words. The words are written in a simple, sans-serif font. The image is simple and straightforward.

Over-The-Counter Use_______

(Optional Format 1-2-96)

---

**Source:** [https://fda-staging.innolitics.com/device/K050382](https://fda-staging.innolitics.com/device/K050382)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com