The Wagner SL Revision Stem Lateral is intended for prosthetic replacement of the proximal femur during total hip arthroplasty. It is intended for press-fit application. Specific diagnostic indications include: Patient conditions of noninflammatory degenerative joint disease (NIDJD), e.g., avascular necrosis, osteoarthritis; and inflammatory joint disease (IJD), e.g., rheumatoid arthritis. Patients with failed previous surgery where pain, deformity, or dysfunction persists. Revision of previously failed hip arthroplasty.
Device Story
The Wagner SL Revision Stem Lateral is a femoral hip prosthesis designed for press-fit implantation. It is manufactured from forged titanium alloy and features a circular cross-section with conical anchorage ribs running nearly the full length of the stem. The device includes a 12/14 taper for modular femoral head connection, a threaded coupling for impaction, and proximal holes for suture attachment. Compared to the predicate, it features a lengthened neck (CCD angle) to achieve lateralization, with widened ribs to compensate for increased bending moments and lateral stresses. It is used by orthopedic surgeons in a clinical/surgical setting to replace the proximal femur, aiming to restore joint function and alleviate pain in patients with degenerative or inflammatory joint disease or failed prior arthroplasty.
Indicated for patients requiring total hip arthroplasty due to noninflammatory degenerative joint disease (e.g., avascular necrosis, osteoarthritis), inflammatory joint disease (e.g., rheumatoid arthritis), failed previous surgery with persistent pain/deformity/dysfunction, or revision of failed hip arthroplasty.
Regulatory Classification
Identification
A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A12 03 ) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.
{0}------------------------------------------------
K04 3356 (pg 1 of 2)
APR 1 8 2005
#### 510(k) SUMMARY
Zimmer Austin, Inc. SPONSOR NAME: 9900 Spectrum Drive Austin, TX 78717
- Zimmer GmbH MANUFACTURER: Sulzer Allee 8 Winterthur, 8404 Switzerland
- Audrey Swearingen CONTACT: Phone: (512) 432-9255 audrey.swearingen@zimmer.com E-Mail:
Wagner SL Revision Stem Lateral TRADE NAME:
Hip joint metal/ceramic/polymer semi-constrained cemented COMMON NAME: or nonporous uncemented prosthesis
Hip joint metal/ceramic/polymer semi-constrained cemented CLASSIFICATION: or nonporous uncemented prostheses (Product Code 87 LZO) are Class II per 21 CFR §888.3353, reviewed by the Orthopedic Devices panel.
PREDICATE DEVICE: Wagner SL Revision Stem (K953689)
#### DEVICE DESCRIPTION:
Both the existing Wagner SL Revision Stem and the proposed Wagner SL Revision Stem Lateral are manufactured from forged titanium alloy and are available in three ിശേഷം വി 6 managan 6 managan (205mm). The neck design of both stems is provided with the standard 12/14 taper for connection with any Zimmer modular femoral head utilizing a 12/14 taper.
The Wagner SL Revision Stem Lateral incorporates a circular stem cross-section and equally spaced conical anchorage ribs, which run nearly the full length of the stem, as do oducily open a previously cleared Wagner SL Revision Stem. The surface of both stems is rough-blasted.
To achieve the lateralization of the modified device, the CCD (i.e., neck) angle was To acrieve the fateralization of the lengthened. To compensate for the increased bending moments and lateral stresses, which result from the increased offset, the rib bending momonto and later of so that the greatest bending moment would not be structure was rib; and the ribs were widened, which led to an increase in the stem strength.
In addition, a threaded coupling was added to the proximal portion of the stem for use m' addition, a throuded couping was shortened and the stem neck with the new impacterese the range of motion, and two small holes were added to the proximal portion of the stem for securing non-metallic suture material.
{1}------------------------------------------------
K043356 (pg. 2 of 2)
### INTENDED USE:
INTENDED OSE.
The Wagner SL Revision Stem Lateral is intended for prosthetic replacement of the The Wagner OL Tevilion of the Eater Eater hip arthroplasty. It is intended for press-fit application. Specific diagnostic indications include:
- ിരക്കം Openino diagnootio immetory degenerative joint disease (NIDJD), e.g., � r attent conditions of neninthritis; and inflammatory joint disease (IJD), e.g., rheumatoid arthritis.
- medifiation artimas.
Patients with failed previous surgery where pain, deformity, or dysfunction persists. �
- Revision of previously failed hip arthroplasty. �
## BASIS OF SUBSTANTIAL EQUIVALENCE:
BASIS OF OODOTARTIAly equivalent in terms of fundamental design, The device, as modified, to casations for use and intended use to the previously cleared, currently marketed Wagner SL Revision Stem.
{2}------------------------------------------------
DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. Inside the circle is an abstract symbol resembling three stylized lines or strokes, possibly representing a stylized human figure or a symbol of health and well-being.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
APR 1 8 2005
Ms. Audry Swearingen Regulatory Affairs Manager Zimmer Austin, Inc. 9900 Spectrum Drive Austin, Texas 78717
Re: K043356
Trade/Device Name: Wagner SL Revision Stem Lateral Regulation Number: 21 CFR 888.3353 Regulation Name: Hip joint metal/ceramic/polymer semi-constrained cemented or Nonporous uncemented prosthesis Regulatory Class: II Product Code: LZO Dated: March 17, 2005
Received: March 21, 2005
Dear Ms. Swearingen:
We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed your Section 3 rQtr) premised is substantially equivalent (for the indications felerenced above and nave determined in marketed predicate devices marketed in interstate for use stated in the encrosure) to regally to regally the Medical Device Amendments, or to conninetee prior to May 20, 1978, the exactions of the Federal Food, Drug, devices that have been reclassified in accerative while in a premarket approval application (PMA). and Cosment Act (Act) that do not require appen o the general controls provisions of the Act. The You may, merelore, market the act include requirements for annual registration, listing of general controls provisions of the rist labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), If your device is classified (36c doove) inc. Existing major regulations affecting your device all in a liting EDA it may be subject to such additional conditions, Title 21, Parts 800 to 898. In addition, FDA can be found in the Code of Feasta, concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not t Please be advised that I DA 3 issuales of a cosenia
that FDA has made a determination that your device complies with other requirements of the Act that FDA has made a delemination administered by other Federal agencies. You must or any receral statutes and regulations and admitted to: registration and listing (21 comply with an the Act 3 requirements, mercessed ing practice requirements as set and CFR Part 807), labeling (21 CFRT art 807), good and frapplicable, the electronic
forth in the quality systems (QS) regulation (21 CFR Part 820), and 11 applicable, 1950 forth in the quality systems (Sections 531-542 of the Act); 21 CFR 1000-1050.
{3}------------------------------------------------
Page 2 – Ms. Audry Swearingen
This letter will allow you to begin marketing your device as described in your Section 5 10(k) I his letter will anow you to begin marketing your artial equivalence of your device to a legally
premarket notification. The FDA finding of substantial equivalence of the p premarket notification. The PDATIManig of basisting of your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please
s and the may and and and and and the color station and the reculation cont if you desire specific advice for your active of your and success not the regulation entitled, the open abtain contact the Office of Collipitalice at (240) 270 Part 807.97). You may obtain
"Misbranding by reference to premarket notification" (21 ct first from the Division of Small "Misbranding by relerence to premarks noutheanon" (2) 300 the Division of Small other general information on your responsion.com its toll-free number (800) 638-2041 or 100-Manufacturers, International and Consumer Prosisanet Prosisanter Propport/index.html.
Sincerely yours,
Stupt Plurle
Miriam C. Provost, Ph.D. Acting Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
# Indications for Use
510(k) Number (if known): 15043356
Wagner SL Revision Stem Lateral Device Name:
Indications for Use:
The Wagner SL Revision Stem Lateral is intended for prosthetic replacement of the proximal Price wagner BB reviewing total hip arthroplasty. It is intended for press-fit application. Specific diagnostic indications include:
- Patient conditions of noninflammatory degenerative joint disease (NIDJD), e.g., avascular � necrosis, osteoarthritis; and inflammatory joint disease (IJD), e.g., theumatoid arthritis.
- Patients with failed previous surgery where pain, deformity, or dysfunction persists. �
- Revision of previously failed hip arthroplasty. �
Prescription Use
X
(Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Stupt Rlurdu
(Division Sign-Division of General, From Stive. and Neurological Devices
510(k) Number K043356
Page of __ of_
(Posted November 13, 2003)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.