VIOPTIX ODISSEY TISSUE OXIMETER TISSUE OXIMETER, MODEL OXY-2
K042657 · Vioptix, Inc. · MUD · Jan 10, 2005 · Cardiovascular
Device Facts
Record ID
K042657
Device Name
VIOPTIX ODISSEY TISSUE OXIMETER TISSUE OXIMETER, MODEL OXY-2
Applicant
Vioptix, Inc.
Product Code
MUD · Cardiovascular
Decision Date
Jan 10, 2005
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.2700
Device Class
Class 2
Indications for Use
The ViOptix ODISsey Tissue Oximeter is intended to non-invasively estimate the percent oxygen saturation (StO2) in a volume of tissue. This is performed in medical environments including physician offices, hospitals, ambulatory care and Emergency Medical Services. The ODISsey Tissue Oximeter is indicated for use in monitoring patients during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation.
Device Story
ODISsey Tissue Oximeter is an optical device for non-invasive estimation of percent oxygen saturation (StO2) in tissue volumes. Device uses near-infrared technology to measure tissue oxygenation; provides real-time StO2 values. Used in hospitals, physician offices, ambulatory care, and EMS settings by clinicians. Output allows assessment of tissue perfusion and oxygen delivery; aids in identifying compromised circulation. Benefits include non-invasive monitoring of skeletal muscle perfusion.
Clinical Evidence
No human clinical data provided. Performance validated via animal study using three dog limbs perfused with an extracorporeal blood circulation system. StO2 values compared against a Radiometer OSM3 Hemoximeter (gold standard) and the Hutchinson InSpectra Tissue Spectrometer. Results demonstrated excellent correlation with both comparators.
Technological Characteristics
Near-infrared tissue oximeter; non-invasive optical sensing principle. Complies with electrical safety, laser safety, and electromagnetic compatibility requirements. Form factor designed for clinical environments. Connectivity and software details not specified.
Indications for Use
Indicated for monitoring patients during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation in medical environments including physician offices, hospitals, ambulatory care, and EMS.
Regulatory Classification
Identification
An oximeter is a device used to transmit radiation at a known wavelength(s) through blood and to measure the blood oxygen saturation based on the amount of reflected or scattered radiation. It may be used alone or in conjunction with a fiberoptic oximeter catheter.
Predicate Devices
InSpectra Tissue Spectrometer System, Model 325 (K012759)
InSpectra Tissue Spectrometer System, Model 325 (K023938)
{0}------------------------------------------------
JAN 1 0 2005
Image /page/0/Picture/2 description: The image shows the logo for ViOptix. The logo consists of the word "ViOptix" in a simple, sans-serif font. The "V" and "O" are connected, and the "x" is stylized to resemble a person with their arms raised. The person is represented by a circle for the head and two angled lines for the arms and body.
44061-B Old Warm Springs Blvd Fremont, CA 94538 510-226-2860 info@vioptix.com
SUMMARY
510-226-5860
510-226-5864
Submitter's name: Address:
ViOptix, Inc. 44061-B Old Warms Springs Blvd. Fremont, CA 94538
Phone: Fax number:
Name of contact person:
Name of the device:
Classification name:
Trade or proprietary name:
Common or usual name:
Greg Holland Requlatory Specialists, Inc 3722 Ave. Sausalito Irvine, CA 92606 Phone: 949-262-0411
Date the summary was prepared: September 27, 2004
ViOptix ODISsey Tissue Oximeter Tissue Oximeter Tissue Spectrometer
The legally marketed device to which we are claiming equivalence [807.92(a)(3)]:
> K012759 and K023938, InSpectra Tissue Spectrometer System, Model 325, manufactured by Hutchinson Technology Inc. and the Biospectrometer NB Oximeter Model 1111 K963903, also manufactured by Hutchinson Technology.
Oximeter
Description of the device:
The ODISsey Tissue Oximeter is an optically based device that noninvasively estimates the percent oxygen saturation (StO2) in a volume of tissue underneath the sensor.
{1}------------------------------------------------
Indications:
The ViOptix ODISsey Tissue Oximeter is intended to non-invasively estimate the percent oxygen saturation (StO2) in a volume of tissue. This is performed in medical environments including physician offices, hospitals, ambulatory care and Emergency Medical Services.
The ODISsey Tissue Oximeter is indicated for use in monitoring patients during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation.
Summary of the technological characteristics of our device compared to the predicate device:
### Technological Characteristics
The technological characteristics of the ODISsey ™ Tissue Oximeter, Model Oxy-2 are similar to those of the cited predicate devices, as well as similar devices based on near-infrared technology. These devices are equivalent in terms of design, functionality, principles of operation, performance specifications and indications for use. When compared to the predicate device, ODISsey ™ Tissue Oximeter, Model Oxy-2 does not raise new technological issues.
#### Indications for Use .
Oximeters and perfusion monitors are used to measure oxygen saturation in the arteries or tissues, or to assess the amount of oxygen delivered to the tissues. Substantial equivalence for the ODISsey ™ Tissue Oximeter, Model Oxy-2 is supported by the predicate devices with identical indications for use.
### Performance Testing
Bench testing, biocompatibility testing, and animal studies, were performed to demonstrate the product functions as intended. The ODISsey ™ Tissue Oximeter, Model Oxy-2 is designed to comply with the requirements of electrical safety, laser safety, and electromagnetic compatibility requirements.
### Animal Testing
The ViOptix ODISsey™ Tissue Oximeter product performance was evaluated against a "gold standard" CO-Oximeter and a FDA cleared predicate device from Hutchinson Testing was performed by measuring tissue oxygen saturation (StO2) on three dog limbs surgically removed and perfused with an extracorporeal blood circulation system. Oxygen perfusion was controlled and monitored by
{2}------------------------------------------------
a Radiometer OSM3™ Hemoximeter (CO-Oximeter). The ViOptix StO2 values were then compared with those from the CO-Oximeter and a Hutchinson's InSpectra™ Tissue Spectrometer. These results show excellent correlation with both the "gold standard" and the predicate device.
## CONCLUSION
Based on the design, technology, performance and functional testing, intended use, and clinical evaluation, the ODISsey ™ Tissue Oximeter, Model Oxy-2 is substantially equivalent to the devices currently marketed under the Federal Food, Drug and Cosmetic Act. The ODISsey ™ Tissue Oximeter, Model Oxy-2 raises no new issues of safety or effectiveness. Therefore, safety and effectiveness are reasonably assured, and substantial equivalence is supported, justifying 510(k) clearance of the ODISsey ™ Tissue Oximeter, Model Oxy-2.
{3}------------------------------------------------
Public Health Service
Image /page/3/Picture/2 description: The image is a circular seal or logo. The seal contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter of the circle. Inside the circle is a stylized graphic of an eagle or bird-like figure with three curved lines representing its wings or body. The image is in black and white.
JAN 1 0 2005
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
ViOptix, Inc. c/o Mr. Greg Holland Regulatory Specialists, Inc. 3722 Ave. Sausalito Irvine, CA 92606
Re: K042657
Trade Name: ODISsey Tissue Oximeter Regulation Number: 21 CFR 870.2700 Regulation Name: Oximeter Regulatory Class: II (two) Product Code: MUD Dated: December 27, 2004 Received: December 28, 2004
Dear Mr. Holland:
We have reviewed your Section 510(k) premarket notification of intent to market the indication we nave reviewed your bocure is substantially equivalent (for the indications relerenced above and nave determined in the enclicate devices marketed in interstate for use stated in the encrosule) to regars manatinent date of the Medical Device American France Friend Free d. Frya commerce prior to may 26, 1976, the encordance with the provisions of the Federal Food. Drug. devices that have been recalismou in accera approval of a premarket approval application (PMA).
and Cosmetic Act (Act) that do not require approval of a premarket approval ap and Cosment Act (Rel) market the device, subject to the general controls provisions of the Act. The I ou may, merciole, market the act include requirements for annual registration, listing of general controls provisions of as tice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), in If your device is classified (500 a0070) ins existing major regulations affecting your device can
may be subject to such additional controls. Existing major regulations and may be subject to suell additional connections, Title 21, Parts 800 to 898. In addition, FDA may be found in the Oous neements concerning your device in the Federal Register.
{4}------------------------------------------------
Page 2 – Page 2 - Mr. Greg Holland
Please be advised that FDA's issuance of a substantial equivalence determination does not mean Please be advised that 1 Dris issuation or our device complies with other requirements of the Act that IDA has made a deceminations administered by other Federal agencies. You must of ally rederal statutes and regulations and limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set CrK Part 807), labeling (21 CFR Part 807), good maximal (20); and If applicable, the electronic (200), 1959 forth in the quality systems (Sections 531-542 of the Act); 21 CFR 1000-1050. product radiation control provisions (Decizens over device as described in your Section 510(k) I his letter will anow you to begin mankeang your antial equivalence of your device to a legally premarket notification. The PDA miams of basification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please If you desire specific acvice for Jour acon 2011 276-0120. Also, please note the regulation entitled, Comaci the Office of Compulance in (21CFR Part 807.97). You may obtain Misoranting by relective to promantonibilities under the Act from the Division of Small other general information on your response Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
B. Blumma for
D.D. Zuckerman, MD
Brand D. Zuckerman, MD Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
# Indications for Use Statement
510(k) Number (if known):
Device Name: ViOptix ODISsey Tissue Oximeter
Indications For Use:
The ViOptix ODISsey Tissue Oximeter is intended to non-invasively estimated The VOplix ODISSey Tissue Oximotor is wolume of tissue. This is performed the percent oxygen saturation (SCS2) in a violes, hospitals, ambulatory care and Emergency Medical Services.
The ODISsey Tissue Oximeter is indicated for use in monitoring patients The ODISSey Trisue Oximeter to muleations of skeletal muscle or when there is a suspicion of compromised circulation.
Prescription Use _____________________________________________________________________________________________________________________________________________________________ (Part 21 CFR 801 Subpart D)
Over-The-Counter Use AND/OR (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Blummera
(Division Sign-Off) Division of Cardiovascular Devices 510(k) Number
Page 1 of ____________________________________________________________________________________________________________________________________________________________________
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.